  1. Symptoms

    A Kubernetes worker node paged with NodeFilesystemFilesFillingUp, the node_exporter mixin alert that predicts a filesystem will run out of inodes. The engineer checked disk space first: df -h showed the root filesystem 83% used, 103G used and 22G available. df -i showed inodes 67% used, 11M used and 5.3M free.

    Trigger

    Several versions of a single-stage Node.js image, each shipping more than 40,000 files, were held on the node; containerd unpacked every layer with a distinct digest into its own snapshot, each with a full copy of node_modules.

    Root cause
    Component
    Contributing factor
    Detection

    The NodeFilesystemFilesFillingUp alert from the node_exporter mixin fired on the predicted inode trend while inode use was at 67%.

    Action items
    • Build the image in multiple stages so the final image contains only the compiled assets
    • Add a flat alert on root filesystem inode use above 80% for 30 minutes alongside the predictive alert
    • Put a Prometheus query on a dashboard that shows, per node, inode usage minus disk usage, sorted from the highest
    • Remove unused images from nodes with crictl rmi --prune to free old snapshots
    Lessons

    kubelet's background cleanup works on bytes only. A workload heavy in small files gets no early intervention for inodes, and the first thing kubelet does at 5% free inodes is evict pods. Watch inode use on nodes separately from disk use, and keep dependency trees out of runtime images.

  2. Symptoms

    From 22:47 UTC on 25 August 2026 the Buildkite web interface, REST API, Agent API, job queue and notifications stopped working for every customer. No one could create a build from the UI or the REST API, job dispatch was delayed, and some builds that were already running when the outage began stayed stuck until the services recovered.

    Trigger

    At 22:44 UTC an application deploy created a surge of new pods, which used up the free capacity on the existing nodes and made the EKS cluster scale out. Background worker pools with unusually high maximum replica counts were scaling out at the same time and kept asking for more pods while new nodes were still being provisioned. Together they produced an unusually high rate of change in applications, network endpoints and nodes, and with it a sudden rise in demand on CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, at 22:55 UTC, eight minutes after the outage began, said something had gone wrong, and at 23:05 UTC the status page said a sitewide outage was being investigated. CoreDNS query duration had been rising as the cluster grew, but a defect in a key monitoring query and too little monitoring of query volume meant this went unnoticed before the outage.

    Remediation
    • paused further application deploys
    • scaled CoreDNS from three to twelve pods
    • raised each CoreDNS pod's memory limit from 512 MiB to 2 GiB
    • expanded the system node pool that runs CoreDNS
    Action items
    • Increase immediate CoreDNS headroom: twelve pods instead of three, a 2 GiB memory limit instead of 512 MiB, and a larger system node pool
    • Enable EKS-managed CoreDNS autoscaling with a tested minimum replica count and enough capacity to spread the replicas across nodes and availability zones
    • Add direct alerts on CoreDNS query duration, query volume, goroutine growth, memory pressure, OOM restarts and available replicas, and track longer-term trends in capacity planning
    • Find other cluster-critical services that lack tested capacity, direct alerting, spread across failure domains, and either safe autoscaling or documented static headroom, and fix them
    Lessons

    A CoreDNS deployment sized once and left at a fixed size can carry a growing cluster for months and then fail on the first burst of churn it cannot absorb. When query processing slows, pending queries take up memory, the pods hit their limits and restart, and client retries keep the service down after the restart. Server-side DNS query duration and volume need their own alerts: here client-side latency was masked by unrelated application speed-ups, and a broken monitoring query hid the server-side trend. Maximum replica counts raised as a temporary measure remove the cap that normally stops runaway scaling when new nodes are slow to arrive.

  3. Symptoms

    An e-commerce platform suddenly became slow to respond, worst on the product lookup page, and users began reporting that the page would not open.

    Trigger

    A post on the external community Ppomppu linked to the platform and brought a large number of users in a short time, who called the product lookup API heavily.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that the product page would not open. The dashboard showed all pods Running, and the namespace CPU usage near 100% and the CPU usage metrics pointed to throttling.

    Remediation
    • raised the HPA minReplicas from 5 to 10
    • raised the container CPU limit from 1 core to 2 cores
    Action items
    • Keep adjusting the CPU limit to a suitable level through monitoring
    Lessons

    CPU throttling is hard to notice: pods stay Running, nothing restarts and the logs show no clear error, so a pod list does not reveal it and CPU usage metrics do. Settings that had handled expected event traffic became the bottleneck as soon as one external post multiplied the traffic. The author concludes that the team needs more preparation for traffic pattern changes and more thought about resource settings.

  4. Symptoms

    Shortly after 29CM's Igu Week sale began on 3 November 2025, the servers for the display domain, which serve search results and product listings, showed anomalies. Some pods went down and stopped taking traffic, and the remaining pods received more traffic than they could handle and saturated their Netty event loops.

    Trigger

    Igu Week, 29CM's largest Black Friday sale and its busiest traffic of the year, raised Redis network traffic to about four times normal.

    Root cause
    Component
    Contributing factor
    Detection

    Anomalies on the display servers, pods going down and Netty event loops saturating, were the first sign. The Redis cause was found from Redis health check failure logs and then the Redis network metrics.

    Remediation
    • Scaled the Redis nodes up from cache.r7g.large to cache.r7g.2xlarge, about twice the baseline network bandwidth
    Action items
    • Extended the monitoring dashboard to show in real time whether network in and out bandwidth exceeds the baseline, with metrics such as aws.elasticache.network_bandwidth_out_allowance_exceeded and aws.elasticache.traffic_management_active
    • Added Datadog alerts that fire when network bandwidth crosses a threshold
    • Added a Caffeine local cache in front of Redis for data that changes rarely
    • Look into compressing cached data with Snappy to reduce Redis network bandwidth
    • Look into storing cached data as Protocol Buffers instead of JSON; measured on the cached Item Document data, Snappy and protobuf together are expected to cut the size by about 73%
    • Keep improving the architecture for traffic growth, building on the cache restructuring, stronger monitoring and read separation already applied
    Lessons

    CPU and memory metrics alone did not show the problem, so Redis needs network monitoring against the node's bandwidth baseline. Burst credits kept the nodes working for about two hours after traffic passed the baseline, which delayed the failure and made its cause slower to find.

  5. Symptoms

    In Microsoft's cloud LLM inference service, the inference engines themselves failed in 94 of the 156 high-severity incidents from April to June 2025 (≈60%). Requests timed out or ran into resource exhaustion under load, and callers got HTTP 408, 429 and 5xx errors.

    Trigger

    Bursty load, traffic with unusually high sampling parameters and long-running requests pushed the inference engines into resource exhaustion and timeouts.

    Root cause
    Component
    Contributing factor
    Detection

    Across the 156 incidents, 115 (≈74%) were auto-detected, meaning health probes or DRI pipelines alerted before customers reported the problem; the others were not.

    Remediation
    • Enabled dynamic pushback at the load balancer with caps on pending tokens and requests
    • Tuned request batching and GPU/CPU replica counts
    • Improved gRPC backoff and error mapping
    • Limited sampling parameters and throttled per client
    • Enabled streaming, tuned request batching and capped pending tokens against engine connection timeouts on long-running requests
    • Increased capacity, routed traffic to healthy endpoints and restarted nodes, the actions applied mostly to inference engine failures
    Action items
    • Optimise serving for long-running requests and high sampling regimes, with connection liveness and GPU capacity-aware routing as the main levers
    • Expand health-probe-driven failover and GPU capacity-aware routing so traffic moves off degraded endpoints on its own
    • Forecast token and throughput growth and automate capacity increase decisions
    • Deploy adaptive alerting and expand engine-level telemetry to close detection gaps
    Lessons

    Hotfixes restore correctness but lengthen time to mitigate, while traffic routing and node rebalancing mitigate faster under overload and timeout patterns. Even with AIOps tooling a meaningful share of incidents still needs manual detection or judgement, so health-probe-driven traffic routing, restarts and capacity increases are the decisions to automate first.

Check your cluster for this

These 16 cases involve kubelet and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion16 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  3. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  4. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  5. IL-0413 LLM inference engines timed out or ran out of resources under load in about 60% of 156 severe incidents at Microsoft
  6. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  7. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  8. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  9. IL-0043 Application logs missing in Kibana after a newer Fluent Bit version changed its chunk drop strategy
  10. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  11. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  12. IL-0401 Prow jobs on the k8s-prow-build GKE cluster failed and merges stalled as nodes hit IOPS throttling and kernel panics
  13. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  14. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  15. IL-0518 gitlab.freedesktop.org on GKE ran short of volume space and a planned 30-minute storage upgrade became a 4-hour outage
  16. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down