Cases7 cases
1 to 5 of 7
IL-0063VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checksAdGuard VPN2025- Symptoms
The day began with an alert that several instances of the Redis cluster were running out of disk space. That part was fixed quickly. The outage came an hour later: right after the Redis StatefulSet was deleted and recreated at 8:10 UTC, Kubernetes restarted every Redis pod within about five minutes, and problems started to appear.
- Trigger
To make Git match the volumes that had been resized by hand, the Redis StatefulSet was deleted with orphan (non-cascading) deletion and recreated with the new storage template; Kubernetes reconciled the new spec by restarting the entire Redis cluster.
- Root cause
- Component
- Contributing factor
- Detection
An alert about Redis instances running out of disk space started the work; the outage itself showed up as backend errors about Redis connections right after the StatefulSet was recreated.
- Remediation
- made the Redis masters forget obsolete node identities, reset the affected replicas and rejoined them, then waited for replication to catch up
- identified the component that was actually running out of memory, scaled the backend service and raised memory limits for that component
- temporarily relaxed probes so backend instances took traffic immediately instead of flapping between ready and not ready
- reverted the temporary workarounds at 10:00 UTC
- Action items
- Add startup probes so a Redis pod is not marked ready until its dataset is loaded
- Build an own control plane for Redis that handles restarted pods stuck to an old master address
- Reduce dependence on the single Redis cluster: move some important data to other stores, such as a separate Redis cluster per server, and use Kafka for some backend components
- Lessons
The disk resize was not the problem; the cleanup afterwards was. An immutable field pushes operators toward deleting and recreating the controller, and that can set off a full reconcile. Startup and readiness probes are what slow a rolling restart down to a safe pace; without them a distributed store restarts in the most fragile way. Recovery plans must expect a cluster to heal slowly, and dependent services need to degrade gracefully while it does.
IL-0100PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queriesPostHog2025- Symptoms
On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.
- Trigger
On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.
- Root cause
- Component
- Contributing factor
- Detection
On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.
- Remediation
- rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
- throttled connections and Redis writes on 21 October
- halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
- rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
- increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
- added retry limits to Envoy between the load balancer and the service
- moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
- added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
- Action items
- Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
- Investigate separating the flags Redis instance from the application Redis instance
- Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
- Make the feature flags team hard code-owners for flags-related code
- Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
- Add missing alerts on existing service and infrastructure metrics
- Make readiness checks validate dependencies that degrade under load, for example by pinging the database
- Rate-limit cache population so it cannot overwhelm Redis
- Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
- Build a production-scale load testing framework
- Build progressive rollout infrastructure to limit blast radius
- Document Postgres-to-Redis data flows and write runbooks for data transfer storms
- Lessons
Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.
- Symptoms
At 11:48 PM PDT on 19 October 2025, every system that reached DynamoDB in us-east-1 through the public regional endpoint started getting DNS failures and could not connect. This included customer traffic and internal AWS services that depend on DynamoDB. DynamoDB global table replicas in other regions still answered but fell behind in replication to and from us-east-1.
- Trigger
One DNS Enactor, slowed by unusually high retry delays, applied a much older DNS plan to the regional DynamoDB endpoint just as another Enactor that had applied the newest plan ran its clean-up, which deleted that older plan and with it every IP address of the endpoint.
- Root cause
- Component
- Contributing factor
- Detection
DNS failures to DynamoDB began immediately at 11:48 PM PDT and the engineering teams of affected AWS services were engaged at once; by 12:38 AM they had identified DynamoDB's DNS state as the source. The later NLB health check problem was detected by monitoring at 6:52 AM.
- Remediation
- applied temporary mitigations by 1:15 AM that let some internal services reach DynamoDB and repaired key internal tooling
- restored all DynamoDB DNS information by 2:25 AM through manual operator intervention
- throttled incoming work and selectively restarted DWFM hosts from 4:14 AM so droplet leases could be re-established
- reduced the load on Network Manager to bring network configuration propagation times back to normal by 10:36 AM
- disabled automatic health check failover for NLB at 9:36 AM, and re-enabled it at 2:09 PM after EC2 recovered
- relaxed the EC2 request throttles from 11:23 AM until all EC2 APIs and launches were normal at 1:50 PM
- Action items
- Disable the DynamoDB DNS Planner and DNS Enactor automation worldwide
- Fix the race condition and add protections against applying incorrect DNS plans before re-enabling the DNS automation
- Add a velocity control to NLB that limits how much capacity a single load balancer can remove when health check failures cause availability zone failover
- Build an additional EC2 test suite that exercises the DWFM recovery workflow at scale
- Improve throttling in EC2 data propagation systems so incoming work is rate limited by the size of the waiting queue
- Lessons
A single DNS record that automation can empty is enough to take a widely used regional endpoint off the network, and every service built on it fails in turn. A check made once at the start of a long operation can be stale by the time the operation writes its result. Recovery of the dependency is not recovery of the dependents: systems that lost state during the outage, such as EC2's droplet leases and network propagation backlog, can collapse under their own catch-up work, and container services that rely on new instance launches keep failing to launch and scale until that work is done.
- Symptoms
Standard alerting paged Honeycomb's on-call engineers about the performance and stability of event ingestion, and the automated load-shedding mechanisms tripped and sent further notifications. The status page described a higher than normal error rate and response time on the ingestion service.
- Trigger
An abnormally large number of queries arrived from many separate connections within a few minutes.
- Root cause
- Component
- Contributing factor
- Detection
Standard alerting notified the on-call engineers about ingestion performance and stability, and the automated load-shedding mechanisms added notifications when they tripped. The first status post, about alerts on a higher than normal error rate and response time, went up at 18:28 PST (02:28 UTC), 13 minutes after the 02:15 UTC start.
- Remediation
- Scaled the ingest fleet up manually and aggressively
- Cut off most ingest for a few minutes so the ingest hosts could come back with enough capacity
- Temporarily lowered the rate limits for the most aggressive traffic sources until their traffic subsided
- Action items
- Keep the ingest fleet scaled up to prevent a repeat while longer-term fixes are worked on
- Decide on the projects that will address these failure paths
- Lessons
Load shedding and auto-scaling were in place, yet a burst that arrived faster than the cache could spread its writes still took the ingest hosts down. During recovery, Kubernetes' crash loop back-off worked against the operators: the hosts that had failed stayed offline while the fleet needed every host. Clients that retry whole OTel batches after a partial drop can multiply traffic many times over, so per-source rate limits were what finally stabilised ingest.
IL-0177WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on NginxLINE Plus2022- Symptoms
The graph of WebSocket connections to messaging-hub, the messaging platform used by the Japanese food delivery service Demaecan, showed sudden deep drops even outside peak traffic. The drops kept coming back at irregular intervals. Messages still reached clients, because messaging-hub switches to Firebase Cloud Messaging when a WebSocket is gone.
- Trigger
Another service that shared the same L7 load balancer deployed its own load balancer configuration in the Verda dashboard, which reloaded HAProxy; 30 minutes later, at the hard-stop-after limit, the old HAProxy process exited and closed every WebSocket connection it still held.
- Root cause
- Component
- Contributing factor
- Detection
The developer noticed deep, sudden drops in the WebSocket connection graph that were not tied to peak traffic and kept recurring irregularly. The Nginx packet drops were found through network monitoring.
- Remediation
- separated the Merchant system's token issuance API into its own deployment so reconnect traffic did not delay other Merchant APIs
- scaled out Nginx with pod anti-affinity and a label selector so each pod ran on a different node, which stopped the nf_conntrack packet drops
- raised Ingress Nginx proxy-read-timeout and proxy-send-timeout and the load balancer timeout to 3600s, which did not stop the drops
- moved messaging-hub from the shared L7 load balancer to an L4 load balancer, which ended the WebSocket drops
- Lessons
A reload of a shared load balancer by a different team can cut long-lived connections, and with hard-stop-after the cut comes 30 minutes later, far from the change that caused it. The author's lesson is not to narrow the scope of the search too early: trusting that the infrastructure was fine kept the investigation inside the team's own systems for days. A reconnect wave from many WebSocket clients can overload the systems that issue connection tokens and fill nf_conntrack on proxy nodes. Scaling Nginx out only helps for conntrack if the pods land on different nodes, and anti-affinity leaves extra replicas Pending once they outnumber the nodes. That messaging-hub problems can still load the connected systems remains an open problem.
These 7 cases involve In-memory cache and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause3
Configuration change3 cases
- Component
- Contributing factor
- Organisation
IL-0063VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checksAdGuard VPN2025IL-0177WebSocket connections to LINE's messaging-hub on Kubernetes dropped all at once whenever another service's change reloaded a shared HAProxy L7 load balancer, and the reconnect wave overloaded a token API and filled nf_conntrack on NginxLINE Plus2022IL-0461Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNSDatadog2022
Capacity exhaustion3 cases
- Contributing factor
- Organisation
IL-0100PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queriesPostHog2025IL-0202A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recoverHoneycomb2023IL-0140The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worseGoogle Cloud2022
Software defect1 case
- Contributing factor
- Organisation