  1. Symptoms

    ByteDance's large language model training jobs on its MegaScale system, which runs on more than 10,000 GPUs, occasionally stalled or slowed down. The cause was network interfaces that flapped frequently.

    Trigger

    Network interfaces went down for several seconds and came back up, dropping every packet in transit.

    Root cause
    Component
    Contributing factor
    Detection

    MegaScale's monitoring system uses second-level monitoring to track link flapping and other NIC issues. When the RDMA traffic metrics carried in the training daemons' heartbeats drop sharply or fluctuate abnormally, the driver raises an alert for manual investigation, and if the traffic stops entirely it starts the fault recovery procedure automatically.

    Remediation
    • set NCCL's timeout threshold explicitly to a larger value than the default
    • tuned NCCL's retransmit timer and retry count for fast recovery under link flapping
    • enabled the adap_retrans feature on the NICs
    • applied lower-level quality control to NIC signal strength, AOC cable quality and switch-side signal strength
    Lessons

    A default NCCL timeout can be shorter than the few seconds an interface needs to come back from a flap, so a brief link loss becomes a failed collective and a stalled job. A larger timeout and faster retransmission give the link time to return, but the flapping itself came from physical link quality between NIC, AOC cable and switch, and quality control at that level reduced it.

  2. Symptoms

    Between 06:00 and 07:00 UTC on 8 March 2023, Kubernetes nodes in several Datadog regions lost network connectivity at the same time, on AWS, Google Cloud and Azure. All services across multiple regions were affected, including the regions that host Datadog's CI/CD and automation tools. Datadog's regions are not connected to each other and changes are rolled out one region at a time, so a simultaneous failure on several cloud providers looked implausible at first.

    Trigger

    On 7 March 2023 Ubuntu published a systemd patch for a CVE (249.11-0ubuntu3.7). Ubuntu's default unattended upgrades installed it on the nodes between 06:00 and 07:00 UTC on 8 March, and installing it restarted systemd-networkd.

    Root cause
    Component
    Contributing factor
    Remediation
    • restarted thousands of disconnected instances on Google Cloud and Azure through the cloud APIs, keeping their local disks
    • rebuilt the data lost with terminated AWS instances' local disks through replication, reprocessing and restores from backup
    Lessons

    A change in a base operating system component can stay dormant for months until something restarts that component. Here the trigger was a security patch, and the change reached every region at once because automatic OS updates ran outside the progressive, region-by-region process used for every other change. Cloud providers react differently to an instance that loses its network. Google Cloud and Azure left the instances running, so a restart recovered them with their disks; AWS replaced them quickly, which brought stateless services back fast but destroyed the local-disk data the stateful services needed.

Check your cluster for this

These 2 cases involve Cilium and NCCL. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause2