Incident Library
  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

  2. Symptoms

    Customers of DigitalOcean Managed Kubernetes (DOKS) saw worker nodes go NotReady between 06:00 and 07:00 UTC and stay unavailable, taking down the services on them, until the nodes were replaced or rebooted; some nodes needed several replacements or reboots. The first sporadic reports on October 8 said replacing the node fixed it. The same thing happened again around 06:00 UTC on October 9, more widely and across many regions, and again on October 10. Only clusters on versions 1.27.6-do.0 and 1.28.2-do.0 were affected.

    Trigger

    A systemd timer in the DigitalOcean Debian image started apt upgrade daily at 06:00 UTC, with a random delay of up to 60 minutes.

    Root cause
    Component
    Contributing factor
    Detection

    Sporadic customer reports of failed worker nodes arrived at 07:43 UTC on October 8; internal incident response started at 07:10 UTC on October 9 after broader impact across regions.

    Remediation
    • Advised customers to replace or reboot affected worker nodes
    • Arranged SSH and console access to worker nodes while they were healthy, and live-debugged an affected node on October 10
    • Released a DaemonSet to all affected clusters that disables the apt upgrade systemd timer on every worker node
    • Released new node images without the auto-update process
    Action items
    • Disable the timer during node provisioning, then remove the DaemonSet from all clusters
    • Add a check to the internal conformance test suite for new cluster versions that the auto-upgrade process and other unwanted timers stay disabled
    • Support logging into worker nodes even when normal access paths are broken
    Lessons

    An operating system auto-update timer left enabled in a node image can change the kernel and systemd underneath Kubernetes, and a timeout that kills the upgrade half-way can leave a node without networking. Failures that start at the same time every day point to a scheduled job on the nodes, and systemd timers belong on that list next to cron jobs. When the failure takes out a node's network, an investigation that depends on logging into the node stalls; access paths that work while the node is broken shorten diagnosis.

Check your cluster for this

These 2 cases involve Cloud controller manager and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.