Cases4 cases
1 to 4 of 4
IL-0063VPN outage after recreating a Redis StatefulSet restarted the whole Redis cluster without readiness checksAdGuard VPN2025- Symptoms
The day began with an alert that several instances of the Redis cluster were running out of disk space. That part was fixed quickly. The outage came an hour later: right after the Redis StatefulSet was deleted and recreated at 8:10 UTC, Kubernetes restarted every Redis pod within about five minutes, and problems started to appear.
- Trigger
To make Git match the volumes that had been resized by hand, the Redis StatefulSet was deleted with orphan (non-cascading) deletion and recreated with the new storage template; Kubernetes reconciled the new spec by restarting the entire Redis cluster.
- Root cause
- Component
- Contributing factor
- Detection
An alert about Redis instances running out of disk space started the work; the outage itself showed up as backend errors about Redis connections right after the StatefulSet was recreated.
- Remediation
- made the Redis masters forget obsolete node identities, reset the affected replicas and rejoined them, then waited for replication to catch up
- identified the component that was actually running out of memory, scaled the backend service and raised memory limits for that component
- temporarily relaxed probes so backend instances took traffic immediately instead of flapping between ready and not ready
- reverted the temporary workarounds at 10:00 UTC
- Action items
- Add startup probes so a Redis pod is not marked ready until its dataset is loaded
- Build an own control plane for Redis that handles restarted pods stuck to an old master address
- Reduce dependence on the single Redis cluster: move some important data to other stores, such as a separate Redis cluster per server, and use Kafka for some backend components
- Lessons
The disk resize was not the problem; the cleanup afterwards was. An immutable field pushes operators toward deleting and recreating the controller, and that can set off a full reconcile. Startup and readiness probes are what slow a rolling restart down to a safe pace; without them a distributed store restarts in the most fragile way. Recovery plans must expect a cluster to heal slowly, and dependent services need to degrade gracefully while it does.
IL-0084Packet drops on a bare metal provider's vSwitch forced Namespace to rebuild its fra3 region and left global capacity short, and the next day slow NVMe writes on a control plane node drove the Kubernetes API server to very high CPUNamespace2024- Symptoms
From 17 October 2024, packets through the vSwitch that joined Namespace's bare metal machines at one provider in the fra3 region were dropped at random. Retries in TCP, QUIC and the Namespace control plane hid most of it, but the SLO error budget for latency targets on key interactions began to burn.
- Trigger
Random packet drops on the bare metal provider's vSwitch from 17 October 2024; for the second outage, a rate of Kubernetes changes that the slow NVMe on one control plane node could no longer keep up with.
- Root cause
- Component
- Contributing factor
- Detection
SLO-based monitoring of latency targets showed the error budget burning while retries hid the individual packet drops.
- Remediation
- diverted all customer traffic from fra3 to other regions
- connected each provider machine to the zrh1 cluster over Wireguard instead of the vSwitch
- repaved every fra3 machine with a new identity, certificates and encryption-at-rest keys, dropping regional caches to recover faster
- cloned existing datasets in a more distributed way to speed up repaving the machines
- added machines back to the new region in batches and returned the region to the compute pool
- redirected workloads away from zrh1 during the second outage
- cloned the failing control plane node's key state to a higher-capacity node that took over its role and IP address
- Action items
- Credit all instances that ran during the outages back to customers
- Build up backup regions and solutions so a similar event has options that do not affect customers
- Lessons
Running hot with a delayed hardware delivery left no room to take a region out, so fixing a provider network fault turned into a global capacity shortage. After one outage the team was anchored on its cause and first looked for network problems in the second outage, which had a different cause: a control plane node whose disk could not keep up with the Kubernetes change rate.
IL-0131A new kind of GenerateContent request made Vertex AI prediction API servers segfault, and once enough of them restarted at the same time the serving fleet could not carry the loadGoogle Cloud2024- Symptoms
From 12:06 US/Pacific on 12 June 2024, services built on Vertex AI Prediction began reporting failed user requests in eight regions: us-central1, asia-southeast1, europe-west3, europe-west4, us-east1, us-west1, northamerica-northeast1 and us-east4.
- Trigger
Starting on 8 June 2024, a new form of user request to the GenerateContent API caused intermittent segmentation faults in the Vertex Serving Prediction API servers; on 12 June the rate of such requests increased.
- Root cause
- Component
- Contributing factor
- Detection
Internal production monitoring alerted engineers to the segfaults on 10 June 2024 at 07:35 US/Pacific, before any visible customer impact; on 12 June services built on Vertex Prediction reported failing user requests.
- Remediation
- confirmed the new failures came from the same segfault found on 10 June
- accelerated the rollout of the fix that was already in progress, completed at 15:59 US/Pacific
- Action items
- Ensure early signals of server binary issues are captured in production health analysis and investigated in time
- Ensure release validation of feature changes and updates in production
- Lessons
A crash that only some requests trigger can stay invisible while load balancers route around the restarting servers. It becomes an outage when the share of such requests grows until too many servers are restarting at once. Here the cause was known and a fix was rolling out two days before customers were affected, but the progressive rollout had not finished when the triggering traffic increased; Google's follow-up is to investigate early signals of server binary issues in time.
IL-0024Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three timesHugging Face2024- Symptoms
At 08:45 CET on 22 April 2024 the Hugging Face Hub became unstable, and by 09:30 it was unresponsive. For most users the website was slow or could not be reached at all.
- Trigger
Bursts of requests to revision endpoints that read heavily from the *_info_cache collections: a call to https://huggingface.co/api/datasets/lighteval/mmlu/revision/main rose sharply right before the first crash, and a call to https://huggingface.co/api/models/sentence-transformers/all-mpnet-base-v2/revision/main, a model with 300+ associated spaces, lined up with the crash at 21:30 on 23 April.
- Root cause
- Component
- Contributing factor
- Detection
Instability started at 08:45 on 22 April and the Hub was unresponsive by 09:30; the team followed MongoDB Atlas metrics and a MongoDB support case. The root cause was found days later from a new graph of requests per URL.
- Remediation
- Added a firewall rule blocking all requests with a Java/* user agent
- Disabled the quicksearch feature on the Hub
- Scaled the MongoDB Atlas cluster by hand from tier 2 to tier 3
- Switched the Hub to maintenance mode with a 503 page through AWS WAF and blocked incoming traffic
- Scaled all Hub pods down to 0 and brought them back
- Set an aggressive rate limit
- Added timeouts to requests and reworked database queries that were slow or returned large bodies
- Action items
- Add timeouts to requests based on their usual completion time
- Optimise requests that took too long or returned a large body, and rework poorly designed database queries
- Remove old unused indexes from the database
- Build new dashboards and monitoring metrics
- Move the *_info_cache collections to Redis
- Make it possible to abort any database request when the client aborts theirs
- Lessons
Finding the root cause took two to three days: the existing charts did not show it, and a per-URL request breakdown did. Not cancelling database work when a client goes away turns a strained database into a thundering herd. A close inspection of the database exposed architectural flaws and bottlenecks, such as a collection with large unused indexes, and taught the team which metrics need closer watching to anticipate crashes. Unrelated failures happening at the same time added to the stress and made restoring service harder.
These 4 cases involve In-memory cache and Cloud load balancer. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause3
Configuration change1 case
- Contributing factor
- Organisation
Cloud provider outage1 case
- Component
- Contributing factor
- Organisation
Software defect2 cases
- Component
- Contributing factor
- Organisation
IL-0131A new kind of GenerateContent request made Vertex AI prediction API servers segfault, and once enough of them restarted at the same time the serving fleet could not carry the loadGoogle Cloud2024IL-0024Expensive cache-backed API calls and uncancelled database requests overloaded MongoDB and took the Hugging Face Hub down three timesHugging Face2024