Cases2 cases
1 to 2 of 2
IL-0226Azure Front Door edge servers crashed worldwide on incompatible configuration metadata, causing timeouts and DNS errorsMicrosoft Azure2025- Symptoms
From 15:41 UTC on 29 October 2025, customers and Microsoft services using Azure Front Door (AFD) and Azure Content Delivery Network (CDN) got connection timeout errors and DNS resolution issues. Monitoring alerts started the investigation at 15:48 UTC.
- Trigger
At 15:35 UTC a specific sequence of valid customer configuration changes, made across two different AFD control plane build versions, produced incompatible customer configuration metadata that was deployed to the edge sites.
- Root cause
- Component
- Contributing factor
- Detection
The configuration protection system detected the data plane impact and blocked configuration changes at 15:43 UTC, and monitoring alerts started the investigation at 15:48 UTC.
- Remediation
- The configuration protection system automatically blocked all new and in-flight configuration changes worldwide
- Removed the problematic customer configurations from the latest LKG snapshot by hand
- Blocked all customer configuration changes from propagating to the data plane
- Deployed the updated LKG configuration across the global fleet
- Moved Azure Portal away from Azure Front Door
- Rebalanced traffic by hand to a few healthy edge sites, then switched back to automatic traffic management
- Blocked all AFD customer configuration changes at the Azure Resource Manager level until safeguards were in place
- Action items
- Fix the control plane incompatibility and the data plane bug
- Process each customer configuration completely and synchronously before production stages
- Add stages to the phased configuration rollout, with longer bake time between them
- Move configuration processing on data plane servers into isolated worker processes
- Reduce configuration propagation time from 45 minutes to about 15 minutes
- Test backwards compatibility with configurations generated by earlier control plane builds
- Move critical first-party infrastructure to an active-active setup with fail away
- Isolate customer configuration and traffic with micro cell segmentation of the AFD data plane
- Restore customer configurations within one hour by using the local configuration cache
- Cut data plane recovery further, to about 10 minutes
- Remove delays in Azure Service Health alerts by raising resource thresholds
- Extend automated Azure Service Health alerts to similar classes of service degradation
- Fail over support request systems faster so Premier and Unified customers can always open requests
- Lessons
Microsoft describes configuration propagation risk as inherent to a global Content Delivery Network, in which route, WAF and origin changes must be deployed quickly worldwide. Both this incident and the 9 October AFD incident came from that risk. This time the incompatible metadata passed a protection system that advances only on healthy data plane signals, because the crash came later from delayed asynchronous processing. Some learnings and repair items from the earlier incident applied here as well. Microsoft advises customers to build a resilient global HTTP ingress layer that stays available during regional or network disruptions, to manage resources through the REST API or PowerShell when management portals are unavailable, and to configure Azure Service Health alerts so the right people hear about service issues.
IL-0253Firefox froze and could not load any web content for close to two hours, stuck in an HTTP/3 request to TelemetryMozilla2022- Symptoms
On 13 January 2022, shortly after 07:28 UTC, Mozilla saw a spike in crashes reported through the Firefox crash reporter and received several reports, from inside and outside Mozilla, of the browser hanging. For close to two hours Firefox was unusable for users worldwide and could not load web content.
- Trigger
At 07:28 UTC on 13 January 2022 GCP deployed an unannounced change that made HTTP/3 the default for load balancers set to "Automatic (default)", so some Firefox connections to Mozilla's services, including Telemetry, started using HTTP/3 instead of HTTP/2.
- Root cause
- Component
- Contributing factor
- Detection
A spike in crashes reported through the Firefox crash reporter, and reports of browser hangs from inside and outside Mozilla.
- Remediation
- Explicitly disabled HTTP/3 on the GCP load balancers at 09:12 UTC
- Action items
- Work with GCP to improve the situation around unannounced changes such as the HTTP/3 default
- Review all service configurations to avoid similar mistakes
- Run more system tests with different HTTP versions
- Find ways to make the browser more resilient to such problems and to speed up incident response
- Lessons
The hang needed three things together: a provider-side change to the HTTP version, a Rust component calling the network stack through viaduct, and a case-sensitive header lookup deep in the HTTP/3 code. Leaving the load balancers on an automatic default let the provider's change apply without any action from Mozilla, and an announcement would likely have led to a controlled test in staging first. A change of HTTP version and an extra networking layer such as viaduct are significant enough to be covered by system tests.
These 2 cases involve CDN and edge network and Cloud load balancer. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Software defect2 cases
- Component
- Contributing factor
- Organisation