Cases2 cases
1 to 2 of 2
IL-0509SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnetSourceHut2024- Symptoms
At about 06:00 UTC on 10 January 2024, SourceHut's monitoring raised the alarm as a layer 3 DDoS attack hit its infrastructure in the PHL datacenter, and at about 09:00 UTC SourceHut lost all access to its PHL network. PHL was the primary datacenter, and the network became unreachable for SourceHut staff and the general public alike.
- Trigger
A layer 3 DDoS attack against SourceHut's PHL infrastructure that began at about 06:00 UTC on 10 January 2024 and broadened to more of the PHL subnet on 11 January.
- Root cause
- Component
- Contributing factor
- Detection
SourceHut's monitoring systems noticed that something was wrong and raised the alarm from about 06:00 UTC on 10 January.
- Remediation
- Got Cogent, through the colocation provider, to narrow the null route from the /24 to the targeted /32, which mostly restored service on 10 January
- Moved DNS to an external DNS provider
- Brought up a new primary database in AMS
- Restored backups from FRE to AMS
- Applied the difference between production data and the last backups by hand
- Provisioned a new mail system and configured the mail services for it
- Set up an OVH box that NATs traffic through OVH's DDoS-resistant network to the production subnet in AMS
- Used a temporary subnet from the PHL network provider for out-of-band access to the PHL servers
- Served pages.sr.ht through an out-of-band link to PHL while its object storage was migrated
- Emailed pages.sr.ht users whose apex records pointed at the PHL subnet with instructions
- Ran build workers on dedicated bare-metal OVH servers
- Action items
- Provision a new standby database
- Configure backups from AMS to FRE
- Install a new monitoring system
- Retire the PHL datacenter installation and ship its servers to AMS
- Move build service back onto SourceHut-operated servers once the build servers are shipped from PHL to AMS
- Research and implement a way to run SourceHut in an on-premise Kubernetes cluster
- Plan a second production-ready datacenter to load balance against, able to take over full service in a datacenter outage
- Lessons
The operational plans SourceHut kept for failures up to the loss of a whole datacenter proved important in this incident. The incident exposed a known shortcoming in redundancy and resilience that the team was working on but had not finished, and the response of the upstream network to the attack did more damage than anything else.
IL-0508All SourceHut services went down when the main database server remilia.sr.ht failed in hardware and became unreachableSourceHut2023- Symptoms
At about 13:40 UTC on 11 January 2023, alerts started firing for most SourceHut services being unavailable, along with one for remilia.sr.ht, the physical host that is SourceHut's main database server. The database server could not be reached remotely at all.
- Trigger
remilia.sr.ht, the main database server, suffered a hardware failure at about 13:38 UTC.
- Root cause
- Component
- Contributing factor
- Detection
Alerts fired at about 13:40 UTC for most services and for remilia.sr.ht itself, after Prometheus started failing to scrape remilia at 13:38.
- Remediation
- Sent SourceHut's emergency on-call contact in the datacenter area to go on site
- Moved remilia's disks into the chassis of build worker cirno1.sr.ht and brought it online as remilia
- Action items
- Make the off-site database copy able to serve as a failover database host
- Re-prioritize the migration to the EU
- Set up new database failover
- Add a new EU build worker to backfill build capacity
- Record a better hardware inventory for future reference
These 2 cases involve BGP routing and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause2
Dependency failure1 case
- Component
- Contributing factor
- Organisation
Hardware failure1 case
- Component
- Contributing factor
- Organisation