IL-0347About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuckScaleway2024- Symptoms
On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.
- Trigger
At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.
- Root cause
- Component
- Contributing factor
- Detection
Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.
- Remediation
- Fixed both VPC route reflectors by manual action
- Action items
- Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
- Run different software versions on the route reflectors so a single bug cannot stop several instances
- Investigate the software issue that left the route reflectors in a stale state
IL-0529New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stoppedGoogle Cloud2024- Symptoms
From 15:22 US/Pacific on 16 May 2024, new VMs and other new instances across Google Cloud came up without network programming, so the new instances could not open network connections, and VMs that were migrated or restarted lost connectivity. Changes to virtual network configuration, such as firewall rules and load balancers, were not applied. Internal monitoring alerted Google engineers at 15:41.
- Trigger
Google's infrastructure team ran a routine maintenance action meant to shut down one unused VPC Controller in a single Google Cloud zone, and the automation shut down VPC controllers in all zones where the controllers were still in use.
- Root cause
- Component
- Contributing factor
- Detection
Internal monitoring alerts reached Google engineers at 15:41 US/Pacific, and the investigation started immediately.
- Remediation
- Paused maintenance operations to prevent the shutdown from repeating
- Brought the affected VPC Controllers back into a serving state in every zone
- Stopped the automation responsible for the shutdown until safeguards are in place
- Recovered partial Apigee proxy deployments by hand
- Cleaned up VMs left behind by failed Dataproc cluster deletions
- Action items
- Add safety measures that check that maintenance operations carry correctly scoped zone information
- Make the underlying tools reject maintenance operations that do not specify zones
- Tighten on-demand access control so one maintenance invocation cannot work across multiple zones
- Add safety checks, testing and validation for maintenance operations, including positive and negative test cases for the new safety measures
- Symptoms
From 7:30 AM JST on 2 September 2021, AWS Direct Connect customers saw intermittent connectivity problems and elevated packet loss on traffic going to their VPCs in the Tokyo (AP-NORTHEAST-1) Region. Internal AWS alarms on Direct Connect packet loss fired at the same time.
- Trigger
Customer traffic consistently generated packets with a very specific set of attributes and contents, and these packets set off a latent defect in the network device operating system on one layer of the Direct Connect network in Tokyo.
- Root cause
- Component
- Contributing factor
- Detection
Internal alarms alerted AWS engineers to elevated packet loss for Direct Connect customers connecting to the Tokyo Region at 7:30 AM JST. The automation that monitors network devices also saw a higher rate of failed devices than normal and alerted engineers.
- Remediation
- Removed the failing network devices from service so healthy devices carried the traffic, which helped only for a time
- Reset failed devices and brought them back into service slowly, without stopping the failures
- Disabled the new protocol in a single Availability Zone, then across the Tokyo Region
- Action items
- Apply the change carefully to all other AWS Regions, with a new way to detect and remediate the issue before customers are affected
IL-0222Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduledGoogle Cloud2019- Symptoms
On Sunday 2 June 2019, with user impact beginning between 11:47 and 11:49 US/Pacific, Google Cloud projects in several US regions saw elevated packet loss from network congestion, and some regions became unreachable. Customers saw higher latency, intermittent errors and lost connectivity to instances in us-central1, us-east1, us-east4, us-west2, northamerica-northeast1 and southamerica-east1, while us-west1, Europe and Asia had no regional congestion.
- Trigger
At 11:45 US/Pacific a relatively rare type of datacenter maintenance event started in one physical location, and the automation that runs it descheduled logical clusters that also held network control plane jobs in other physical locations.
- Root cause
- Component
- Contributing factor
- Detection
Google engineers were alerted to the failure two minutes after it began and started the incident process used for the most serious production incidents. The first customer notice appeared on the status page at 12:53 US/Pacific.
- Remediation
- Lowered the priority of less critical network traffic classes to reduce congestion
- Halted the datacenter automation software responsible for the maintenance event
- Rescheduled the network control plane and its supporting infrastructure in each location
- Rebuilt and redistributed the lost network control plane configuration, rolling it out from 14:03
- Directed service traffic away from the affected regions
- Moved the Cloud VPN control plane in three regions out of its fail-safe state
- Action items
- Keep the maintenance automation off until safeguards stop it descheduling jobs in several physical locations at once
- Harden the cluster management software to reject such requests whatever their origin
- Reconfigure the network control plane to reject maintenance requests of the type involved
- Make the network control plane in each location persist its configuration
- Let the network stay in fail static mode longer when the control plane is lost
- Review, update and test emergency response tooling and procedures, including customer communication tooling, for such network failures
- Extend continuous disaster recovery testing to this and similarly catastrophic failures
These 4 cases involve Network control plane (SDN) and BGP routing. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Software defect4 cases
- Component
- Contributing factor
- Organisation
IL-0347About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuckScaleway2024IL-0529New Google Cloud VMs and other instances came up without network connectivity in all zones after VPC controllers stoppedGoogle Cloud2024IL-0336AWS Direct Connect traffic into the Tokyo Region had packet loss and intermittent connectivity for about six hoursIL-0222Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduledGoogle Cloud2019