Cases2 cases
1 to 2 of 2
IL-0422Metadata inconsistencies in Crusoe Cloud's VAST storage in eu-iceland1-a caused I/O errors and failed VM operationsCrusoe Cloud2025- Symptoms
On 16 December 2025 at 17:13 UTC, Crusoe Cloud reported slowness in Shared Storage in its eu-iceland1-a region, which runs on storage from its vendor VAST. Within half an hour the scope was widened to significant slowness and intermittent access problems for Shared Storage users, affecting shared disks and GPU virtual machines in eu-iceland1.
- Root cause
- Component
- Contributing factor
- Remediation
- Implemented a fix for the storage performance issues, returning latency and throughput to normal
- Ran a targeted integrity verification with the storage cluster in a protective maintenance state
- Lifted the broad protective maintenance restrictions after the critical phase of the verification
- Changed the configuration to isolate background recovery processes from active customer workloads
- Ran integrity scans and automated remediation workflows modelled on validated manual recovery procedures
- Upgraded the VAST storage software to add automated tooling for recovery
- Rebooted the VAST cluster to restore access to shared volumes and VM operations
- Applied a configuration update to the storage nodes to speed up recovery workflows
- Remediated the storage node failures of 28 December
- Applied further VAST storage software upgrades on 28, 30 and 31 December and 1 January
- Action items
- VAST to run a full post-incident review and add automation and safeguards that remove reliance on manual steps
- Review the recent stability of the storage cluster with the vendor to prevent recurrences
IL-0420PCIe links on IBM's Vela GPU nodes dropped to a lower generation's speed and slowed training jobs by up to 2xIBM2025- Symptoms
On IBM's Vela AI cluster, GPU nodes with PCI-E Gen3 and Gen4 links sometimes performed like a much older PCI-E generation, for example at 4 GB/s, which resembles PCI-E Gen 1. Training jobs on those nodes slowed by anywhere from a few percent to 2x, and PCI-E link downgrades were the most frequently observed failure on Vela.
- Root cause
- Component
- Contributing factor
- –
- Detection
Autopilot measures PCI-E bandwidth between host and device on every node with periodic lightweight tests, and an alert fires when the average of 12 hourly samples falls below a threshold for the PCI-E generation; affected nodes are listed on a Grafana dashboard.
- Remediation
- Reset the PCI-E device, usually by rebooting the VM, which resolved the downgrade at least 95% of the time
- Rebooted VMs periodically
- Action items
- Run periodic lightweight PCI-E link tests through Autopilot on every node and alert when the 12-hour average falls below a threshold
- Keep investigating the root cause of the PCI-E link degradations
- Lessons
In distributed training, a drop in the performance of a single node reduces the performance of the whole job until the slow node is identified and removed or fixed. Lightweight periodic tests averaged over a long window can find degraded PCI-E links accurately while customer jobs keep running, which lets site reliability engineers act before users report a problem.
These 2 cases involve PCIe link and Shared network filesystem. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
unknown2 cases
- Component
- Contributing factor
- Organisation