  1. Symptoms

    On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.

    Trigger

    At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.

    Root cause
    Component
    Contributing factor
    Detection

    At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.

    Remediation
    • Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
    • Moved API traffic that could use read replicas to the secondary data center by hand
    • Sent authentication calls fully back to the primary data center when the dashboard got worse
    • Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
    • Ramped the turned-down services back up so asynchronous processing could catch up
    Action items
    • Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
    • Redesign the user sessions system so dashboard traffic can be steered between data centers
    • Change the auto-remediation configuration so a database replica is not promoted so quickly
    • Tune each system involved to be more resilient to failures of its dependencies
    Lessons

    Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.

  2. Symptoms

    At 11:59AM CDT on Friday 28 August 2020, Basecamp's Ops team received a flood of alerts from PagerDuty, Nagios and Prometheus. Monitoring showed that the newer of the two metro links between the data centers in Ashburn, VA and Chicago, IL had been lost for about 20-30 seconds, and BC3 kept responding slowly after the link came back.

    Trigger

    Both redundant metro links between Basecamp's Ashburn and Chicago data centers dropped for short periods; monitoring showed the newer link down for about 20-30 seconds.

    Root cause
    Component
    Contributing factor
    Detection

    A flood of alerts from PagerDuty, Nagios and Prometheus, with monitoring showing the lost metro link. A lingering alert for one Redis DB instance later pointed to the replication problem.

    Remediation
    • Turned chat off at the load balancer layer so the rest of BC3 could stabilise
    • Restarted Redis on the replica that was stuck in the resynchronization loop
    Action items
    • Make the documented Redis configuration changes for the known replication issue
    • Make concrete plans to remove the shared physical path under the two metro links
    • Prove the failover systems in production at peak load
    • Make explicit room for post-incident follow-up work and push other work out
    Lessons

    Planned redundancy and live testing had given Basecamp a false sense of security, especially at peak load: moving between redundant network links or shifting load across data centers should work without issue, and Basecamp would rather find out in a controlled test with the full team ready. The follow-up from an outage needs urgency and explicitly cleared time, not just a place on a list.

  3. Symptoms

    A reader of Repro's Aurora MySQL cluster restarted for no known reason, and right after that the writer's insert latency rose to about seven times normal and writer performance stayed badly degraded for a long time. This happened more than once, twice within two weeks by 11 November 2019. While the writer was slow, the applications that process data collected by the Repro SDK fell behind, and the team could only watch until the writer recovered.

    Trigger

    Long-running queries on the reader; the author recalls that the cause was a query sent to the reader from Redash.

    Root cause
    Component
    Contributing factor
    Remediation
    • Waited for writer performance to return, since the rollback segment release could not be sped up
    Action items
    • Add a monitor on the rollback segment, mysql.innodb.history_list_length in Datadog
    • Kill queries that run long enough to make the reader restart as soon as they are found
    • Set max_execution_time so queries are stopped after a fixed time
    Lessons

    Once the rollback segment has grown large, nothing speeds up its release across the cluster, so the way to avoid the latency is to keep transactions small and stop long-running queries before the rollback segment grows.

  4. Symptoms

    At 18:40 UTC db1075, the primary database of section s3, stopped answering, and all s3 wikis went read-only because no writes could reach it. Reads kept working from the replicas. At 18:42:45 Icinga reported "PROBLEM - Host db1075 is DOWN: PING CRITICAL - Packet loss = 100%".

    Trigger

    The RAID battery backup unit (BBU) of db1075, the s3 primary database host, failed and the whole host crashed.

    Root cause
    Component
    Contributing factor
    Detection

    Icinga reported db1075 HOST DOWN on IRC at 18:42:45, but that alert does not page; replica Slave IO alerts followed, users reported problems on #wikimedia-operations, and the first SMS page went out at 18:56. Volunteers and staff noticed the failure before the alerts did.

    Remediation
    • Power-cycled db1075 from the iDRAC after finding the BBU problem
    • Let MySQL finish InnoDB recovery on db1075
    • Removed read_only=ON from db1075 by hand
    • Ran puppet by hand a second time so pt-heartbeat started
    Action items
    • Implement or refactor a script that moves replicas when the primary is unavailable
    • Fix the MediaWiki heartbeat model so pt-heartbeat does not use a super-user, avoids a single point of failure and follows the real primary without depending on puppet
    • Decide what to do with the batch of hosts that already had BBU issues
    • Buy a new BBU for db1075
    • Remove db1075 from the primary role
    • Address MediaWiki spam while the database is read-only or the primary is unavailable
    • Make primary database hosts page on HOST DOWN
    • Track hardware errors better in Netbox
    Lessons

    A BBU failure should not crash a whole host, yet it had happened before on HP hosts. HOST DOWN on a primary database should page instead of only alerting on IRC. Starting pt-heartbeat through puppet races with MySQL startup, and the unnoticed failure kept lag reported and made the outage 8 minutes longer.

  5. Symptoms

    At 22:54 UTC on 21 October 2018 GitHub's internal monitoring started alerting on many faults at once. By 23:02 UTC the first responders saw that the replication topologies of many MySQL clusters were in an unexpected state: the Orchestrator API showed topologies made only of servers in the US West Coast data center. When connectivity came back, the application tier had immediately started sending writes to the new West Coast primaries.

    Trigger

    At 22:52 UTC on 21 October, routine maintenance to replace failing 100G optical equipment cut connectivity between GitHub's US East Coast network hub and its primary US East Coast data center for 43 seconds.

    Root cause
    Component
    Contributing factor
    Detection

    GitHub's internal monitoring raised alerts on numerous faults at 22:54 UTC, two minutes after the partition. By 23:02 UTC the first responders had found, by querying the Orchestrator API, that many database clusters had a topology with only US West Coast servers.

    Remediation
    • Locked the internal deployment tooling to stop further changes
    • Paused webhook delivery and GitHub Pages builds to stop jobs writing metadata
    • Restored the affected MySQL clusters from backups into the US East Coast data center and let them replicate from the West Coast
    • Found ways to restore directly from the West Coast to get around the throughput limits of downloading from off-site storage
    • Moved all database primaries back to the US East Coast data center
    • Spread read traffic over additional MySQL read replicas in the US East Coast public cloud so replication could catch up
    • Failed over to the original topology once the replicas were in sync
    • Processed the backlog of webhook events and Pages builds, pausing to raise an internal TTL after about 200,000 webhook payloads were dropped
    Action items
    • Reconcile the writes from the captured MySQL binary logs that were not replicated, automatically where possible and with user outreach otherwise
    • Make sure status updates can be published even when GitHub Pages builds are paused
    • Give more accurate public estimates of the time to repair
    • Configure Orchestrator so it cannot promote database primaries across regional boundaries
    • Move to a status reporting mechanism that shows the status of each component of the platform
    • Serve GitHub traffic from multiple data centers in an active/active/active design with N+1 redundancy at the facility level
    • Test assumptions about the system more proactively
    • Validate failure scenarios systematically, with investment in fault injection and chaos engineering tooling
    Lessons

    Orchestrator did what it was configured to do, but the application tier could not work with primaries on the other side of the country: leader election within one region is generally safe, while the sudden cross-country latency was a major contributing factor. The behaviour emerged from a partition larger than any GitHub had seen. Replication caught up along a power decay curve, not a straight line, so the linear estimates of recovery time were wrong. GitHub concluded that tighter operational controls and faster response are not enough on their own and that failure scenarios have to be validated before they happen.

Check your cluster for this

These 12 cases involve Database replication and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Capacity exhaustion4 cases

  1. IL-0379 InfluxDB Cloud queries in Azure West Europe slowed and timed out as storage pods fell behind and kept restarting
  2. IL-0305 Replicas of one Intercom Vitess shard hit 100% CPU and fell up to 2.2 hours behind, serving stale inbox data
  3. IL-0443 A Repro Aurora MySQL reader restarted unexpectedly and writer insert latency rose about sevenfold for a day or more
    Repro2019
  4. IL-0296 Transloadit's us-east Redis cluster lost queued jobs and heartbeats, raising WORKER_JOB_ERROR errors for 81 customers

Software defect2 cases

Organisation
  1. IL-0376 A maintenance update set off needless full syncs between Upstash Redis replicas in eu-west-1, slowing the databases
  2. IL-0303 GitHub's MySQL master failed over to a node with a cold buffer pool during a schema migration and GitHub.com went down
    GitHub2012

Breaking change in an upgrade1 case

Organisation
  1. IL-0308 Most RevenueCat backend systems failed after cutover to a new Aurora PostgreSQL 14 cluster as queries became very slow

DNS or network fault2 cases

Organisation
  1. IL-0240 Cloudflare API requests failed and the dashboard slowed for hours after the authentication database lost its replicas
  2. IL-0210 GitHub's MySQL clusters failed over to the US West Coast and the site served slow, stale, inconsistent data for 24 hours
    GitHub2018

Dependency failure1 case

Organisation
  1. IL-0255 Basecamp's two redundant links between data centers dropped together and a Redis replica resync loop stalled chat

Hardware failure1 case

  1. IL-0323 A RAID battery backup unit failure crashed db1075, the MariaDB primary of section s3, and every s3 wiki went read-only

Configuration change1 case

Organisation
  1. IL-0430 Mackerel's Redis stopped answering during a replication setup, keepalived failed over by mistake, and Mackerel degraded
    Hatena2018