  1. Symptoms

    On 15 February 2019 a slave node of the AWS ElastiCache Redis Cluster behind Apollo, Grab's driver-side state machine for transport bookings, failed and had to be replaced. For about one minute only roughly 1 in 21 calls to Apollo succeeded, a call failure rate above 95% against the Redis Cluster, and Grab rides were significantly down.

    Trigger

    A slave node of Apollo's Redis Cluster failed and needed to be replaced.

    Root cause
    Component
    Contributing factor
    Lessons

    Having several replicas did not protect Apollo, because the client side, not the Redis Cluster server, caused the failure. Grab suggests three ways to avoid it: a separate Redis Cluster client used only for pipelining with RouteByLatency set to true, so pipelined reads go through the master nodes when latency is under 1ms, watching master CPU because they take more load; checking the error of each command in a pipeline instead of failing the whole call, so successful queries are not affected; and changing the Go-Redis library so that the pipeline path reloads the nodes' state when an error happens, as defaultProcessor already does.

  2. Symptoms

    At about 14:01 PDT on 13 October 2017, Discord engineers were alerted to anomalies by real-time metrics and monitoring. A Redis instance that was the primary of a highly available cluster used by the API services had dropped offline after Google Cloud Platform migrated it automatically, and some API instances did not handle the failover to the secondary node correctly.

    Trigger

    Google Cloud Platform automatically migrated the Redis instance that was the primary of a highly available cluster used by the API services, and the node incorrectly dropped offline.

    Root cause
    Component
    Contributing factor
    Detection

    Real-time metrics and monitoring alerted engineers at 14:01 PDT. The second phase was seen at 15:41 as another anomaly in monitoring, and end user reports of servers appearing offline were escalated at 15:42.

    Remediation
    • Ran a rolling restart of all API instances to clear the Redis connection issues
    • Corrected the misconfigured edge caching rule for the expensive API route
    • Disabled the problem API endpoint on the edge network
    • Recovered the Cassandra cluster
    • Ran a second rolling restart of all API instances for the latency left by the Cassandra issues
    • Removed the misbehaving guilds node from the service hashring
    • Forcefully restarted the misbehaving guilds node
    • Restarted the whole service, forcing all users to reconnect
    • Blocked traffic that relied on the failing push component to reduce its load
    • Corrected the API setting that lets users reconnect quickly and safely
    Action items
    • Fix the known issues with Redis failover within the coming weeks
    • Change the cached route so this type of error does not degrade other services
    • Monitor the signals that would have warned of the cascading failure
    • Improve the reliability and failure handling of the affected services
    • Roll out an update of the library with the suspected flaws
Check your cluster for this

These 7 cases involve In-memory cache and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Software defect7 cases

  1. IL-0376 A maintenance update set off needless full syncs between Upstash Redis replicas in eu-west-1, slowing the databases
  2. IL-0216 Wikimedia on-wiki search was slow or rejected after a datacenter switchover overloaded one Elasticsearch node in codfw
  3. IL-0217 Honeycomb's main MySQL database locked up under cache-miss reads and ran out of connections, a 68-minute total outage
  4. IL-0295 Pusher's Channels publish API on the mt1 cluster was largely unavailable for 11 minutes while a Redis master failed over
    Pusher2022
  5. IL-0213 Roblox was down for 73 hours because key-value writes on its single Consul cluster slowed from under 300 ms to 2 seconds
    Roblox2021
  6. IL-0279 One failed Redis Cluster replica left only about 1 in 21 calls to Grab's Apollo service succeeding for a minute
    Grab2019
  7. IL-0388 A Google Cloud live migration took a Discord Redis primary offline, and the failover broke API instances and then guilds