Incident Library
Applied filters SymptomThroughput degradationClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases7 cases

6 to 7 of 7

  1. Symptoms

    At 4:53 pm Pacific on 25 January 2023 one of OpenAI's GPU clusters had a major outage, and the text-davinci-003 model went fully down.

    Trigger

    A configuration change to the CNI (Container Network Interface) plugins, which provide network connectivity to containers, was deployed to a GPU cluster that contained a hardware variant the staging environment did not have.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers immediately identified the problem as network connectivity, but it took nearly an hour to identify CNI as the cause.

    Remediation
    • put a fix for the CNI configuration change in place, which restored 80% of traffic immediately
    • deployed models back onto GPUs over about three more hours until capacity was fully stable
    Action items
    • Make staging environments contain every type of hardware configuration so they better represent production
    • Monitor and alert on the health of the CNI system directly
    • Fix the network and storage bottlenecks that limit how quickly many replicas of a model can be deployed
    Lessons

    A change that had been deployed to other clusters over 24 hours and deemed safe still broke a cluster with different hardware, so staging needs every hardware configuration that production has.

  2. Symptoms

    A production service at Airbnb showed a high error rate and could not be deployed. The deploy failed with a cryptic Kubernetes error about being unable to access invalid index 5.

    Trigger

    A change to the mutating admission controller, which had been rolled out within the previous month, had gone in seven days before the incident surfaced; when it had to delete two items from an array in a spec, it generated an invalid JSON patch that removed index 2 and then index 3.

    Root cause
    Component
    Contributing factor
    Detection

    The affected service reported a high error rate and its deploy failed; the slow degradation of other services over the previous seven days had gone unnoticed.

    Remediation
    • deleted the mutating admission controller from the affected cluster
    Action items
    • Create alerts from the existing metrics that would have shown the problem earlier
    Lessons

    Keep in mind that a mutating admission controller exists in the cluster; a recently added one is easy to forget during an incident. Search for the exact error message early instead of working on the visible symptoms. Page a teammate when progress stalls.

Check your cluster for this

These 7 cases involve NCCL and Shared network filesystem. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Capacity exhaustion2 cases

  1. IL-0137 Training initialisation on a 60-node NVIDIA B200 cluster took more than 8 hours instead of minutes because fragmented small random I/O from all nodes saturated the metadata service of the VAST Data NFS storage
  2. IL-0129 Throughput of the 384-GPU SmolLM3 pretraining run collapsed because shared WekaFS storage evicted dataset shards to S3, then kept dropping on local NVMe because the nanotron dataloader built an index that grew with the step count

Dependency failure1 case

Organisation
  1. IL-0025 Failed boots, InfiniBand link flapping, NCCL hangs and throughput sags while bringing up a 4,088-GPU H100 training cluster
    Imbue2024

DNS or network fault1 case

Contributing factor
Organisation
  1. IL-0128 Network interfaces that dropped for a few seconds made NCCL time out and stalled or slowed LLM training on a cluster of more than 10,000 GPUs

Breaking change in an upgrade1 case

Organisation
  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers

Configuration change1 case

Component
Organisation
  1. IL-0116 A CNI configuration change incompatible with a hardware variant that exists only in production cut network connectivity in an OpenAI GPU cluster and took text-davinci-003 fully down
    OpenAI2023

Software defect1 case

Organisation
  1. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods