  1. Symptoms

    The hub pod of the prod JupyterHub on the leap cluster (leap.2i2c.org) restarted unexpectedly during a large node scale-up, and a user opened a support ticket. The ingress-nginx and proxy pods kept running.

    Trigger

    A user's dask-gateway workload added about 100 dask-worker nodes within a minute, and Prometheus started scraping the metrics exporters on about 200 nodes.

    Root cause
    Component
    Contributing factor
    Detection

    A user support ticket (2i2c Freshdesk ticket 414) about the leap hub; the engineer then looked at Grafana and the cluster's nodes and events.

    Action items
    • Configure CPU and memory requests for the hub and proxy pods (#2127; at least 100m CPU was proposed)
    • Make the Grafana OOMKiller dashboard work (#2213)
    • Move LEAP cloud infrastructure to shared nodes (#2209)
    • Update resource requests and limits, mainly for ingress-nginx and Prometheus (#2324)
    • Decide whether Prometheus should scrape dask worker pods (#2366)
    Lessons

    Prometheus load grows with the number of nodes, so a burst of autoscaled nodes can push a nearly full core node over the edge and evict the pods that matter most. Core pods that request 10m of CPU get a tenth of the CPU share of busy neighbours that request 100m. Kubernetes events expire after an hour, so evidence of OOM kills needs a dashboard that keeps it.

  2. Symptoms

    At 08:52 PM IST a report came in from WER that many students could not access the JupyterHub and that it was frozen; pages were stuck and nothing was usable. A rise in activity was visible by 09:02 PM, but the usual fixes, such as opening an incognito window and restarting servers, did not help.

    Trigger

    WER students' pods used a good chunk of their memory limit (tests had shown they almost always use just under 1G of their 2G limit, against a 512M guarantee) on nodes shared with the hub's core pods.

    Root cause
    Component
    Contributing factor
    Detection

    WER reported stuck pages and students unable to reach the hub in a GitHub issue (2i2c-org/docs#27).

    Remediation
    • removed memory overcommit for the WER students
    • raised resource guarantees for all core pods, which restarted them and moved some to a new node
    Action items
    • Put user pods in a separate pool so they do not create pressure on the core pods (infrastructure#89)
    • Set limits on the support infrastructure (Prometheus, Grafana, ingress) as well (infrastructure#90)
    • Document and think about overcommit ratios for memory usage (infrastructure#91)
    • Set up better Grafana dashboards to monitor resource usage (infrastructure#92)
    • Document how people can get kubectl access to the cluster so others can look into issues too (infrastructure#87)
    Lessons

    Core pods without resource guarantees get whatever is left on a node, so when user pods on the same nodes fill the CPU and memory, the hub that serves everyone freezes. The memory overcommit ratio has to come from measured use: WER students used just under 1G against a 512M guarantee, which a 4x overcommit could not hold.

  3. Symptoms

    Shortly after a round of changes, loveholidays saw connectivity problems and raised error rates on its aggregation service. The service is a proxy between two other services of more than 100 instances each, handles over 10,000 requests per second continuously and can spike to four times that.

    Trigger

    Three changes together: a change in service architecture, halving the RAM of the nodes that run the aggregation service, and sharding a downstream service, which doubled the number of connections to track.

    Root cause
    Component
    Contributing factor
    Detection

    Rising error rates and climbing connection reset errors in HAProxy, then node_exporter conntrack metrics compared with their limit.

    Remediation
    • moved the aggregation service to nodes with more RAM
    • limited the number of aggregation service pods per node
    Action items
    • Alert when conntrack table use goes above 75%, with (node_nf_conntrack_entries / on (pod) node_nf_conntrack_entries_limit / on (pod) group_right kube_pod_info) > 0.75
    Lessons

    The conntrack limit is tied to node memory, so resizing a node pool silently resizes the connection table, and on GKE the ratio did not match the commonly cited formula. A high-traffic proxy on small nodes can exhaust it, and the symptoms are connection resets and timeouts, so conntrack use needs its own metric and alert.

  4. Symptoms

    A colleague wrote in Slack that his application was taking a long time to deploy. A deployment that normally finishes in minutes had been running for about an hour: about half of the new pods were running and serving traffic, and the other half were Pending.

    Trigger

    The cluster reaching 256 nodes, the most its /16 pod secondary range could hold at 256 addresses per node; every further node creation failed.

    Root cause
    Component
    Contributing factor
    Detection

    A colleague reported in Slack that a deployment was slow; the pending pods' events and the cluster autoscaler status ConfigMap showed the exhausted IP space.

    Remediation
    • lowered the maximum pods per node on selected node pools, cutting IP consumption by about 30%
    • moved some node pools to larger instance types
    Action items
    • Lower the maximum pods per node on node pools that do not run many pods
    • Use larger instance types in some node pools
    Lessons

    In a VPC-native GKE cluster the number of nodes, not the number of pods, uses up the pod range: by default each node reserves 256 addresses, so even a /16 is full at 256 nodes. Maximum pods per node and node size are the practical levers; larger nodes pack better but take more pods down when they fail.

Check your cluster for this

These 11 cases involve Node pool and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing