Incident Library
Applied filters SymptomHigh error rateFactorUnreviewed defaultsClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases8 cases

8 to 8 of 8

  1. Symptoms

    Customers of the Zalando Fashion Store got a high rate of errors on all web product pages and outfit pages for more than an hour. The errors came from the main data aggregation layer service, which runs in one of Zalando's Kubernetes clusters.

    Trigger

    Calls from the aggregation layer to a single, not very important downstream service started timing out. The aggregation layer returned 404s for them, clients retried, and the resulting spike in requests became a spike in DNS queries to CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The on-call engineer for the aggregation layer phoned the on-call Kubernetes engineer. Automatic paging did not happen because the cluster's monitoring and alerting ran inside the cluster and failed along with DNS. The Kubernetes engineer then saw that the CoreDNS pods were being OOM-killed.

    Remediation
    • Raised the CoreDNS memory requests and limits by hand from 100Mi to 2000Mi
    Action items
    • Introduce a more resilient DNS setup: CoreDNS fronted by dnsmasq on every node
    • Improve high-level alerting from outside the clusters, so that a cluster problem is known before or at the same time as applications are affected
    • Improve incident response processes and tooling so that any on-call engineer can escalate directly to other teams when automatic paging fails, for example through a chat bot
    Lessons

    The Kubernetes DNS setup was far from resilient enough: a single application could take down DNS for everything in the cluster. The blast radius of one application sending more DNS queries should be limited to one node at most, ideally to single pods. Known Kubernetes DNS problems, such as Linux kernel races in conntrack handling and the ndots 5 problem, were familiar to the team and partly mitigated, but their combined effect on the DNS infrastructure was worse than the team had understood. Monitoring that runs inside the cluster was not robust enough: when the cluster's DNS broke, it could not page anyone, and recovery took longer than it should have.

Check your cluster for this

These 8 cases involve CoreDNS and Cloud load balancer. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause5

Faulty deployment1 case

Organisation
  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy

Capacity exhaustion3 cases

Organisation
  1. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  2. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  3. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries

DNS or network fault2 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0178 On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB

Software defect1 case

Component
Organisation
  1. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes

Configuration change1 case

Organisation
  1. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019