Incident Library
Applied filters SymptomHigh error rateDomainKubernetesClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases62 cases

11 to 15 of 62

  1. Symptoms

    On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.

    Trigger

    On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.

    Root cause
    Component
    Contributing factor
    Detection

    On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.

    Remediation
    • rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
    • throttled connections and Redis writes on 21 October
    • halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
    • rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
    • increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
    • added retry limits to Envoy between the load balancer and the service
    • moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
    • added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
    Action items
    • Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
    • Investigate separating the flags Redis instance from the application Redis instance
    • Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
    • Make the feature flags team hard code-owners for flags-related code
    • Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
    • Add missing alerts on existing service and infrastructure metrics
    • Make readiness checks validate dependencies that degrade under load, for example by pinging the database
    • Rate-limit cache population so it cannot overwhelm Redis
    • Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
    • Build a production-scale load testing framework
    • Build progressive rollout infrastructure to limit blast radius
    • Document Postgres-to-Redis data flows and write runbooks for data transfer storms
    Lessons

    Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.

  2. Symptoms

    At 11:48 PM PDT on 19 October 2025, every system that reached DynamoDB in us-east-1 through the public regional endpoint started getting DNS failures and could not connect. This included customer traffic and internal AWS services that depend on DynamoDB. DynamoDB global table replicas in other regions still answered but fell behind in replication to and from us-east-1.

    Trigger

    One DNS Enactor, slowed by unusually high retry delays, applied a much older DNS plan to the regional DynamoDB endpoint just as another Enactor that had applied the newest plan ran its clean-up, which deleted that older plan and with it every IP address of the endpoint.

    Root cause
    Component
    Contributing factor
    Detection

    DNS failures to DynamoDB began immediately at 11:48 PM PDT and the engineering teams of affected AWS services were engaged at once; by 12:38 AM they had identified DynamoDB's DNS state as the source. The later NLB health check problem was detected by monitoring at 6:52 AM.

    Remediation
    • applied temporary mitigations by 1:15 AM that let some internal services reach DynamoDB and repaired key internal tooling
    • restored all DynamoDB DNS information by 2:25 AM through manual operator intervention
    • throttled incoming work and selectively restarted DWFM hosts from 4:14 AM so droplet leases could be re-established
    • reduced the load on Network Manager to bring network configuration propagation times back to normal by 10:36 AM
    • disabled automatic health check failover for NLB at 9:36 AM, and re-enabled it at 2:09 PM after EC2 recovered
    • relaxed the EC2 request throttles from 11:23 AM until all EC2 APIs and launches were normal at 1:50 PM
    Action items
    • Disable the DynamoDB DNS Planner and DNS Enactor automation worldwide
    • Fix the race condition and add protections against applying incorrect DNS plans before re-enabling the DNS automation
    • Add a velocity control to NLB that limits how much capacity a single load balancer can remove when health check failures cause availability zone failover
    • Build an additional EC2 test suite that exercises the DWFM recovery workflow at scale
    • Improve throttling in EC2 data propagation systems so incoming work is rate limited by the size of the waiting queue
    Lessons

    A single DNS record that automation can empty is enough to take a widely used regional endpoint off the network, and every service built on it fails in turn. A check made once at the start of a long operation can be stale by the time the operation writes its result. Recovery of the dependency is not recovery of the dependents: systems that lost state during the outage, such as EC2's droplet leases and network propagation backlog, can collapse under their own catch-up work, and container services that rely on new instance launches keep failing to launch and scale until that work is done.

  3. Symptoms

    In Microsoft's cloud LLM inference service, the inference engines themselves failed in 94 of the 156 high-severity incidents from April to June 2025 (≈60%). Requests timed out or ran into resource exhaustion under load, and callers got HTTP 408, 429 and 5xx errors.

    Trigger

    Bursty load, traffic with unusually high sampling parameters and long-running requests pushed the inference engines into resource exhaustion and timeouts.

    Root cause
    Component
    Contributing factor
    Detection

    Across the 156 incidents, 115 (≈74%) were auto-detected, meaning health probes or DRI pipelines alerted before customers reported the problem; the others were not.

    Remediation
    • Enabled dynamic pushback at the load balancer with caps on pending tokens and requests
    • Tuned request batching and GPU/CPU replica counts
    • Improved gRPC backoff and error mapping
    • Limited sampling parameters and throttled per client
    • Enabled streaming, tuned request batching and capped pending tokens against engine connection timeouts on long-running requests
    • Increased capacity, routed traffic to healthy endpoints and restarted nodes, the actions applied mostly to inference engine failures
    Action items
    • Optimise serving for long-running requests and high sampling regimes, with connection liveness and GPU capacity-aware routing as the main levers
    • Expand health-probe-driven failover and GPU capacity-aware routing so traffic moves off degraded endpoints on its own
    • Forecast token and throughput growth and automate capacity increase decisions
    • Deploy adaptive alerting and expand engine-level telemetry to close detection gaps
    Lessons

    Hotfixes restore correctness but lengthen time to mitigate, while traffic routing and node rebalancing mitigate faster under overload and timeout patterns. Even with AIOps tooling a meaningful share of incidents still needs manual detection or judgement, so health-probe-driven traffic routing, restarts and capacity increases are the decisions to automate first.

  4. Symptoms

    From about 02:29 UTC on 24 September 2025, customers of Linode Kubernetes Engine (LKE) in US-Southeast (Atlanta) could not manage their clusters, and autoscaling was impacted. Internal logs showed 5xx errors whenever customers tried to manage LKE clusters associated with the affected cluster controller.

    Trigger

    Old certificates on the LKE cluster controllers were revoked at 02:29 UTC on 24 September 2025, after the expiring certificates had been rotated on 23 September.

    Root cause
    Component
    Contributing factor
    Remediation
    • deployed a fix for the certificate key mismatch
    • restarted the API endpoints
    Action items
    • Continue investigating the root cause and take preventive actions
  5. Symptoms

    From 7:43 PM to 8:38 PM PDT on July 15, 2025, a small percentage of ChatGPT users saw more errors in their conversations.

    Trigger

    An internal engineer applied a configuration change that contained an invalid value.

    Root cause
    Component
    –
    Contributing factor
    Remediation
    • reverted the configuration to the correct value
    • started a rolling restart of the affected pods to force them to resynchronise
    Action items
    • Roll out future critical configuration changes for the service to a single cluster first, with automated health guards that stop the rollout if availability drops
    • Move to a service-specific configuration value instead of one shared between services
    • Improve deployment safeguards
Check your cluster for this

These 62 cases involve Database and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Configuration change14 cases

  1. IL-0179 With DEBUG logging and synchronous log output, a high-traffic service filled the 64 KB stdout pipe, so request threads blocked in write() while holding database connections and HikariCP ran dry, failing requests in 30-second bursts
  2. IL-0200 Newly provisioned Kubernetes nodes ran an incompatible etcd version and broke cluster consensus in several GitHub production clusters, causing 5XX errors on Git operations and page loads
    GitHub2026
  3. IL-0122 An invalid value in a configuration shared by several ChatGPT services put pods into crash loops and raised error rates
    OpenAI2025
  4. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  5. IL-0118 A global change to Kubernetes namespace labels made the networking layer recompute metadata and overwhelmed the control planes of three of OpenAI's largest GPU clusters
    OpenAI2024
  6. IL-0459 MediaWiki on Kubernetes terminated TLS with a wrong certificate after a deployment, and 1% of requests failed
  7. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  8. IL-0461 Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNS
  9. IL-0208 A GitLab chart bump that renamed Kubernetes Service and Deployment ports made the GCP load balancer reconfigure, and GitLab.com slowed down and returned intermittent 50x errors
    GitLab2022
  10. IL-0442 Older pods on LIFULL's KEEL Kubernetes cluster were preempted all at once and the external error rate spiked
    LIFULL2021
  11. IL-0105 Replacing the AWS VPC CNI during a Terraform refactoring detached the ALB target groups, and every service in the Kubernetes cluster returned 503
    DFDS2021
  12. IL-0004 A new default pod priority let a new Cortex cluster preempt every production ingester in a cascade, taking Grafana Cloud Hosted Prometheus down
  13. IL-0066 Broken ConfigMap change lay dormant for weeks, then took down Pusher's edge proxy when a cluster upgrade replaced its pods
    Pusher2019
  14. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Capacity exhaustion21 cases

  1. IL-0471 GitHub Actions runs failed or sat queued for 9 hours after a routine deployment's pod replacement saturated capacity
    GitHub2026
  2. IL-0435 Error rates rose as Aurora MySQL killed connections and declined queries to avoid OOM while load metrics stayed flat
  3. IL-0465 IONOS Container Registry image pushes and pulls failed with 504 Gateway Timeout
  4. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  5. IL-0413 LLM inference engines timed out or ran out of resources under load in about 60% of 156 severe incidents at Microsoft
  6. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  7. IL-0204 An etcd memory spike overloaded the control plane of a Render Frankfurt cluster, and DNS then failed because CoreDNS ran on the rebooted control plane nodes and could not start without the API server
    Render2024
  8. IL-0232 Calico pods in the codfw WikiKube cluster hit their resource limits and crash-looped, taking nodes out one by one
  9. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  10. IL-0433 Shifting API traffic from EC2 to EKS on Fargate overloaded two CoreDNS pods and caused mass name-resolution errors
  11. IL-0500 UToronto JupyterHub logins and server starts returned 500 errors when the hub's sqlite database disk filled up
    2i2c2022
  12. IL-0140 The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worse
  13. IL-0206 Consul agents in GitLab.com's GKE pods were repeatedly OOM-killed, so the Rails pods lost database replica discovery and sent every query to the primary
    GitLab2022
  14. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  15. IL-0002 CI builder pods could not get AWS IAM credentials because kubelet fell minutes behind its API rate limit
  16. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  17. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  18. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  19. IL-0031 Kubernetes API server OOM-killed, leaving the Skipper ingress without routes; the talk points to a misconfigured CronJob manifest
  20. IL-0518 gitlab.freedesktop.org on GKE ran short of volume space and a planned 30-minute storage upgrade became a 4-hour outage
  21. IL-0468 New JupyterHub student pods stuck Pending on MaxVolumeCount after a memory limit cut with node size unchanged

Cloud provider outage5 cases

  1. IL-0438 Builder Work became almost entirely unreachable with 504 errors when the Amazon CloudFront VPC Origins feature failed
    ANDPAD2026
  2. IL-0542 Twingate authentication and authorization requests failed at higher rates after traffic moved onto a smaller GKE cluster
  3. IL-0119 ChatGPT web service pods crash-looped on failing health checks after a Cosmos DB failure, leaving too few healthy pods to serve the web layer
    OpenAI2025
  4. IL-0145 A power sag and chiller failure in one Australia East availability zone took down the AKS control plane's compute and its non-zone-redundant SQL Database operation queue, blocking AKS create, update and delete operations in Australia East and Australia Southeast
  5. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage

Breaking change in an upgrade4 cases

  1. IL-0092 Upgrading ingress-nginx from 1.12.0 to 1.14.3 brought a newer ModSecurity and OWASP Core Rule Set whose false positives blocked HMPPS Auth, so users could not sign in to their applications
  2. IL-0236 After an Istio 1.15 to 1.24 upgrade, half of Wikimedia's ML model servers returned 5XX for about a day
  3. IL-0201 A framework upgrade caused kernel panics in GitHub's Kubernetes infrastructure, and GitHub.com web and API requests, mostly for issues and pull requests, failed intermittently for about 16 hours
    GitHub2025
  4. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

Faulty deployment2 cases

  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  2. IL-0324 Three MediaWiki deployments lost Memcached after a PHP 8.1 rollout and overloaded the External Storage database cluster

Data loss or corruption1 case

Contributing factor
Organisation
  1. IL-0474 Harness Feature Flags auth returned 502s when rescheduled pods could not get an image deleted from Artifact Registry

Software defect9 cases

  1. IL-0150 A latent race condition in DynamoDB's DNS automation left an empty DNS record for dynamodb.us-east-1.amazonaws.com, and the DynamoDB and EC2 launch failures that followed caused EKS, ECS and Fargate container launch failures and cluster scaling delays in us-east-1
  2. IL-0495 HubSpot's internal load balancers on Kubernetes were falsely marked unhealthy and the rest collapsed under the traffic
  3. IL-0151 A latent defect in the AWS Lambda Frontend, set off when one us-east-1 cell scaled past a size never reached before, raised errors for Lambda and for services that depend on it, including new EKS cluster provisioning
  4. IL-0106 A malformed Traefik IngressRoute triggered a Traefik v2 bug once a node rollover restarted every Traefik pod, and all Kubernetes services returned 404
    DFDS2021
  5. IL-0032 Mutating admission controller generated broken JSON patches, silently blocking deploys for a week until a production service ran down to two pods
    Airbnb2020
  6. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes
  7. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020
  8. IL-0074 All AirMap platform services down as worker nodes went NotReady and pods crash-looped on network and DNS failures
    AirMap2018
  9. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Certificate or credential expiry1 case

Contributing factor
Organisation
  1. IL-0156 Revoking old certificates after a rotation left a certificate key mismatch between API endpoints and the cluster controller, and LKE cluster management and autoscaling in Atlanta returned 5xx errors
    Linode2025

DNS or network fault3 cases

  1. IL-0083 Intermittent 5xx errors in a multi-tenant Kubernetes cluster came from internal DNS: the node-local dnsmasq hit its 150 concurrent query limit, did not cache cluster.local answers, and ndots search lookups flooded CoreDNS
  2. IL-0178 On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB
  3. IL-0049 Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entries
    Preply2020

Operator error2 cases

Organisation
  1. IL-0207 A routine task run from an engineer's local environment switched to production and deleted GitLab.com's Consul release, so Patroni lost Consul and GitLab.com returned 5xx errors to all traffic
    GitLab2022
  2. IL-0115 One of OpenAI's three production AKS clusters went offline through a human error, and rebuilding it took 10½ hours because an AKS Kubernetes upgrade broke the ingress and AKS cannot be downgraded
    OpenAI2022