  1. Symptoms

    While running the CI process on a local machine to test an application Helm chart, the SRE lead watched the pods with watch kubectl get pods. All pods reached Running, and then some went back to Pending. Two hours later the problem had grown and some pods showed the phase Unknown.

    Trigger

    A CI run installed the application's Helm charts for all four markets (Efritin.com, Tonaton.com, Ikman.lk and Bikroy.com) on the nonproduction cluster at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The SRE lead saw pods go from Running back to Pending while watching kubectl get pods during the CI run; no monitoring raised an alert, even when all three workers were not ready.

    Remediation
    • terminated the three worker nodes and let the auto scaling group replace them
    Action items
    • Fix the Datadog integration for the nonproduction AWS account and repeat the installs with telemetry
    • Increase the worker root EBS volumes from 20GB to 120GB
    • Keep common base images pulled on every node with a DaemonSet until kops supports user hooks
    • Configure different allocation limits for the different layers in Kubernetes
    • Discuss a highly available Tiller with the Helm team
    • Find a way to throttle the number of newly created pods
    Lessons

    An ordinary deploy of the application could collapse the cluster, because the default 20GB gp2 root volumes could not keep up with parallel image pulls and container starts. Without node metrics and pod phase metrics, three NotReady workers raised no alert. A single Tiller replica can block the deploy that would fix an outage.

Check your cluster for this

These 13 cases involve Container memory limit and Telemetry agent. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion13 cases

  1. IL-0071 Worker node running out of inodes while disk space looked fine, because containerd kept a full node_modules tree in each of several image layer snapshots
  2. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  3. IL-0137 Training initialisation on a 60-node NVIDIA B200 cluster took more than 8 hours instead of minutes because fragmented small random I/O from all nodes saturated the metadata service of the VAST Data NFS storage
  4. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  5. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  6. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  7. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  8. IL-0043 Application logs missing in Kibana after a newer Fluent Bit version changed its chunk drop strategy
  9. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  10. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  11. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API
  12. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries
  13. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down