Incident Library
Applied filters ComponentNode poolClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases36 cases

14 to 18 of 36

  1. Symptoms

    At 16:40 UTC on 19 April 2024 CoW Protocol's mainnet production environment stopped producing settlements; the outage officially began then.

    Trigger

    During a cluster capacity expansion, the Infrastructure as Code automation updated the AWS VPC CNI plugin, because the CNI version was not hardcoded in the IaC and the IaC library version had recently changed.

    Root cause
    Component
    Contributing factor
    Detection

    The CNI version mismatch was identified as the cause at 17:03 UTC, 23 minutes after settlements stopped.

    Remediation
    • upgraded the Kubernetes cluster
    • set up new node groups with a new version of the networking plugin
    Lessons

    Versions in IaC scripts should be specified explicitly so an automation run cannot update a component such as the CNI plugin unintentionally. Changes in production need change management that is easy to revert.

  2. Symptoms

    From 08:00 US/Pacific on 12 March 2024, GKE GPU nodes running Container-Optimized OS (COS) that were newly created or recreated came up with GPU drivers that did not work, so workloads that used the GPUs could not run. GKE showed elevated errors.

    Root cause
    Component
    Contributing factor
    Detection

    The report does not say how Google detected the issue. Affected users saw "Failed to download GPU driver installer, status: 403 Forbidden" on the GPU node when installing the driver.

    Remediation
    • Halted automatic node recreations, which attempt GPU driver downloads, until the issue was mitigated
    • Worked with the driver partner to resolve access to the driver download bucket
    Lessons

    The status page report states no lessons or follow-up actions.

  3. Symptoms

    At 13:42 the RootVolUtilisation-Critical alert fired in the high-priority alerts channel. At 14:03 a user reported image pull errors with the message "no space left on device".

    Trigger

    Upgrading the EKS Terraform module to version 18, which changed the node launch template, and draining workloads onto the new nodes it created.

    Root cause
    Component
    Contributing factor
    Detection

    The RootVolUtilisation-Critical alert fired in the high-priority alerts channel at 13:42, and a user reported "no space left on device" image pull errors at 14:03.

    Remediation
    • Uncordoned the old default node group and drained the new nodes to move workloads back
    • Identified the launch template change that cut the root volume to 20 GB and applied a fix on the manager and live clusters
    • Drained the old node group onto the fixed nodes
    Action items
    • Update the runbook to compare launch template changes during an EKS module upgrade
    • Create a test setup that pulls images of different sizes, like live
    • Update the RootVolUtilisation alert runbook to check the disk space configuration
    • Scale CoreDNS dynamically based on the number of nodes
    • Investigate whether IPv6 can solve the IP prefix starvation problem
    • Add drift testing to identify when a terraform plan shows a change to the launch template
    • Set up logging for the CNI and ipamd logs and alerts on errors related to IP prefix starvation
    Lessons

    The write-up lists review actions rather than lessons. They aim at two gaps: the launch template changes brought by a module upgrade were not compared or drift-tested before rollout, and there were no CNI or ipamd logs or alerts to show the IP prefix starvation the team suspected during the drain.

  4. Symptoms

    At 14:05 on 25 July 2023, a high-priority PagerDuty alert from Pingdom reported that the "Prometheus - live healthcheck" was DOWN. Prometheus on the live cluster was unavailable, and the Cloud Platform lost its monitoring for a while.

    Trigger

    The growing number of namespaces and Prometheus rules raised Prometheus' memory needs beyond what its node instance size could hold.

    Root cause
    Component
    Contributing factor
    Detection

    A Pingdom health check on Prometheus failed and raised a high-priority PagerDuty alert.

    Remediation
    • drained the monitoring node, moving Prometheus to another monitoring node
    • changed the node instance size to r6i.4xlarge
    • raised the Prometheus memory limit to 100Gi
    • set the Prometheus container limits to 12 CPU cores and 110Gi of memory
    Action items
    • Add an alert on node memory usage and on a pod using up most of a node's memory (issue #4538)
  5. Symptoms

    At 08:15 a user posted in the #ask-cloud-platform channel that new deployments were not starting: their pods stayed in ContainerCreating.

    Root cause
    Component
    Contributing factor
    Detection

    A user reported new deployments stuck in ContainerCreating in the #ask-cloud-platform channel at 08:15; the incident was declared at 09:31.

    Remediation
    • Added new nodes and cordoned and drained the six affected nodes
    • Enabled prefix delegation in the VPC CNI on the live cluster after comparing its CNI settings with a 1.23 test cluster
    Action items
    • Add a test or check that confirms IP address allocation is working as expected (#4669)
    Lessons

    The write-up states no lessons beyond its review action, which is to add a check that IP address allocation works.

Check your cluster for this

These 36 cases involve Node pool and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing

Faulty deployment5 cases

  1. IL-0166 A compute host update removed the credential parser used to decode StackScripts, so new Linodes and every new LKE and LKE-E node failed to boot and autoscaling and node recycling failed in all regions
    Linode2026
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down
  3. IL-0163 An API change that slipped through a gap in automated testing made LKE clusters resize to the wrong number of nodes and added billable worker nodes to customer accounts
    Linode2023
  4. IL-0164 An incremental Linode Kubernetes Engine production update that was missing changes from the previous release made cluster upgrades and node additions fail silently
    Linode2022
  5. IL-0149 Upgrades of AKS clusters on Virtual Machine Scale Sets failed with a 'platform image is not available' error after a service update left a backend service unhealthy

Certificate or credential expiry2 cases

  1. IL-0158 An expired credential caused authentication failures that stopped LKE and LKE-E from deploying clusters and nodes in all regions, which also blocked node recycling and cluster autoscaling
    Linode2026
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect

Breaking change in an upgrade1 case

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours

Software defect4 cases

  1. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  2. IL-0078 Enabling EKS secrets encryption with KMS through Terraform removed worker node IAM permissions and took down all ZenML Pro workspaces
    ZenML2025
  3. IL-0161 A faulty earlier API update made new LKE cluster provisioning in Toronto time out for three days, leaving clusters with no node pools or the wrong number of nodes
    Linode2024
  4. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes

Configuration change6 cases

  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours
  2. IL-0019 An EKS Terraform module upgrade shrank node root disks from 100 GB to 20 GB and image pulls failed with no space left on device
  3. IL-0017 AWS VPC CNI stopped allocating pod IP addresses on six nodes of the live cluster, leaving new pods in ContainerCreating
  4. IL-0091 Changing the worker node instance type through Terraform recycled all nodes at once and deleted users' production pods together
  5. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  6. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Operator error2 cases

  1. IL-0018 A Docker Hub password rotation left EKS nodes and Concourse locked out of Docker Hub and unable to pull images
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage3 cases

  1. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021