  1. Symptoms

    At 10:23 on 6 June 2023 a user of the Cloud Platform reported that all of their production pods had been deleted at the same moment. Several users received Pingdom alerts that their applications were down for a few minutes.

    Trigger

    The team changed the instance type of the cluster's worker nodes through Terraform.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that their production pods had been deleted at once and that Pingdom alerts showed their applications down; the incident was declared at 11:00.

    Action items
    • Ask AWS, through a support ticket, for the steps to change the node instance type without an outage
    • Plan how to make instance type changes through Terraform without downtime and add a runbook with the steps for changing the node instance type
  2. Symptoms

    Resizing an LKE cluster produced an incorrect number of nodes, so some customer clusters were resized in unexpected ways and the extra worker nodes were billed to the customer accounts. The clusters themselves kept functioning. Linode's first status update, at 05:07 UTC on 1 June 2023, advised customers to avoid resizing their clusters if possible.

    Trigger

    At about 16:00 UTC on 31 May 2023 a change to the API that caused LKE clusters to scale improperly was pushed to production.

    Root cause
    Component
    Contributing factor
    Detection

    The first status update, at 05:07 UTC on 1 June, said Linode had been made aware of an issue when resizing LKE clusters, about 13 hours after the change went out.

    Remediation
    • advised customers to avoid resizing their clusters
    • deployed a hotfix at 09:40 UTC on 1 June that corrected the scaling behaviour
    • left the extra worker nodes in place to avoid disrupting customer workloads
    • contacted affected customers by ticket about credit adjustments and further mitigation
    Action items
    • Audit the automated tests
    • Add pre-deployment checklist items so the same failure does not happen again
    Lessons

    An API change that alters scaling behaviour resized customer clusters and added cost while the clusters themselves kept working; Linode announced the issue about 13 hours after the change went out. Removing the extra nodes would have disrupted workloads, so the cost was handled through credits instead.

  3. Symptoms

    At 09:33 UTC on 14 February 2023 end users told the platform team that Kubernetes logs were not arriving in CloudWatch as expected. The investigation went through fluentd and found that the nodes were running containerd as their container runtime instead of docker-shim. A scheduled node rollover the day before, at 07:30 UTC on 13 February, had set containerd as the default runtime by accident.

    Trigger

    A scheduled node rollover had accidentally made containerd the default container runtime, which stopped log shipping to CloudWatch; the unscheduled rollover to revert it timed out, and the pipeline run that followed reduced the Auto Scaling group from 30 to 15 instances.

    Root cause
    Component
    Contributing factor
    Detection

    End users reported the missing CloudWatch logs that started the work. The postmortem lists 2 minutes as the time to detection of the node failure.

    Remediation
    • ran the node rollover script to add new nodes, which failed on a timeout from Docker Hub
    • ran the node rollover script a second time, which added new nodes that the load balancer marked healthy at 11:01 UTC
    Action items
    • Document the rollover process, especially what can be done when it goes wrong
    • Investigate options for improving the rollover process
    • Add fluentd log collection to the QA test suite so logs are covered end to end
    • Add alarms for fluentd when too little or no log data is sent
    • Implement a staging environment
    • Implement guards against selecting an invalid container runtime
    Lessons

    When a change goes wrong, rolling back to a known working configuration is safer than rushing a fix, which can make the damage worse. Launching new worker nodes depends on the cloud-init script not failing in any way. The QA configuration differed from production, there was no staging environment, the QA tests did not cover fluentd log collection, and the rollover process had no documentation for when it fails.

  4. Symptoms

    The hub pod of the prod JupyterHub on the leap cluster (leap.2i2c.org) restarted unexpectedly during a large node scale-up, and a user opened a support ticket. The ingress-nginx and proxy pods kept running.

    Trigger

    A user's dask-gateway workload added about 100 dask-worker nodes within a minute, and Prometheus started scraping the metrics exporters on about 200 nodes.

    Root cause
    Component
    Contributing factor
    Detection

    A user support ticket (2i2c Freshdesk ticket 414) about the leap hub; the engineer then looked at Grafana and the cluster's nodes and events.

    Action items
    • Configure CPU and memory requests for the hub and proxy pods (#2127; at least 100m CPU was proposed)
    • Make the Grafana OOMKiller dashboard work (#2213)
    • Move LEAP cloud infrastructure to shared nodes (#2209)
    • Update resource requests and limits, mainly for ingress-nginx and Prometheus (#2324)
    • Decide whether Prometheus should scrape dask worker pods (#2366)
    Lessons

    Prometheus load grows with the number of nodes, so a burst of autoscaled nodes can push a nearly full core node over the edge and evict the pods that matter most. Core pods that request 10m of CPU get a tenth of the CPU share of busy neighbours that request 100m. Kubernetes events expire after an hour, so evidence of OOM kills needs a dashboard that keeps it.

  5. Symptoms

    At 14:22 a Cloud Platform team member noticed failed Docker Hub logins. Fetching an image returned: failed to fetch manifest: Head "https://registry-1.docker.io/v2/ministryofjustice/cloud-platform-tools/manifests/2.1": toomanyrequests: too many failed login attempts for username or IP address

    Trigger

    The Docker Hub password was changed as part of LastPass remediation activities while the EKS cluster nodes and Concourse still logged in with the previous password.

    Root cause
    Component
    Contributing factor
    Detection

    A Cloud Platform team member saw the failed Docker Hub login error at 14:22. The Kuberhealthy daemonset check showed at 14:52 that the cluster could not pull images, and a user reported ErrImagePull in #ask-cloud-platform at 14:54.

    Remediation
    • Changed the Docker Hub password back to the previous value still used by the EKS cluster nodes and Concourse
    • Confirmed with the reporting user that the pod deployed and that cluster image pulls worked again
    Action items
    • Switch from the Docker Hub username and password to a Docker Hub token created specifically for Cloud Platform
    • Rotate the password cleanly out of hours with a graceful recycle of the nodes
    Lessons

    The write-up states no separate lessons. Its review action replaces the Docker Hub username and password with a Docker Hub token created specifically for Cloud Platform.

Check your cluster for this

These 36 cases involve Node pool and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing

Faulty deployment5 cases

  1. IL-0166 A compute host update removed the credential parser used to decode StackScripts, so new Linodes and every new LKE and LKE-E node failed to boot and autoscaling and node recycling failed in all regions
    Linode2026
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down
  3. IL-0163 An API change that slipped through a gap in automated testing made LKE clusters resize to the wrong number of nodes and added billable worker nodes to customer accounts
    Linode2023
  4. IL-0164 An incremental Linode Kubernetes Engine production update that was missing changes from the previous release made cluster upgrades and node additions fail silently
    Linode2022
  5. IL-0149 Upgrades of AKS clusters on Virtual Machine Scale Sets failed with a 'platform image is not available' error after a service update left a backend service unhealthy

Certificate or credential expiry2 cases

  1. IL-0158 An expired credential caused authentication failures that stopped LKE and LKE-E from deploying clusters and nodes in all regions, which also blocked node recycling and cluster autoscaling
    Linode2026
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect

Breaking change in an upgrade1 case

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours

Software defect4 cases

  1. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  2. IL-0078 Enabling EKS secrets encryption with KMS through Terraform removed worker node IAM permissions and took down all ZenML Pro workspaces
    ZenML2025
  3. IL-0161 A faulty earlier API update made new LKE cluster provisioning in Toronto time out for three days, leaving clusters with no node pools or the wrong number of nodes
    Linode2024
  4. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes

Configuration change6 cases

  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours
  2. IL-0019 An EKS Terraform module upgrade shrank node root disks from 100 GB to 20 GB and image pulls failed with no space left on device
  3. IL-0017 AWS VPC CNI stopped allocating pod IP addresses on six nodes of the live cluster, leaving new pods in ContainerCreating
  4. IL-0091 Changing the worker node instance type through Terraform recycled all nodes at once and deleted users' production pods together
  5. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  6. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Operator error2 cases

  1. IL-0018 A Docker Hub password rotation left EKS nodes and Concourse locked out of Docker Hub and unable to pull images
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage3 cases

  1. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021