  1. Symptoms

    From 11:45 UTC on 16 April 2026, customers of Linode Kubernetes Engine (LKE) and Linode Kubernetes Engine Enterprise (LKE-E) could not deploy new clusters or add new nodes to existing clusters. Because no new node could be deployed, node recycling and cluster autoscaling did not work either. The problem hit every region where LKE runs.

    Trigger

    A credential expired, which caused authentication failures when LKE and LKE-E deployed clusters and nodes. One status update describes it as an expired certificate.

    Root cause
    Component
    Contributing factor
    –
    Detection

    The first status page update, saying the team was investigating an emerging issue affecting LKE and LKE-E in all regions, was posted at 13:20 UTC.

    Remediation
    • created new credentials and deployed them, rotating the expired credential (certificate)
    Action items
    • Investigate what led to the credential expiry and take preventive actions
    Lessons

    One expired credential stopped every operation that needs a new node, in all regions at once: new clusters, added nodes, node recycling and autoscaling.

  2. Symptoms

    On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.

    Trigger

    On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.

    Root cause
    Component
    Contributing factor
    Detection

    On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.

    Remediation
    • rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
    • throttled connections and Redis writes on 21 October
    • halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
    • rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
    • increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
    • added retry limits to Envoy between the load balancer and the service
    • moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
    • added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
    Action items
    • Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
    • Investigate separating the flags Redis instance from the application Redis instance
    • Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
    • Make the feature flags team hard code-owners for flags-related code
    • Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
    • Add missing alerts on existing service and infrastructure metrics
    • Make readiness checks validate dependencies that degrade under load, for example by pinging the database
    • Rate-limit cache population so it cannot overwhelm Redis
    • Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
    • Build a production-scale load testing framework
    • Build progressive rollout infrastructure to limit blast radius
    • Document Postgres-to-Redis data flows and write runbooks for data transfer storms
    Lessons

    Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.

  3. Symptoms

    Nodes that already existed kept running, but every new node, spot or standard, on either v1.32 or v1.33, failed to initialise and could not join the cluster. Spot nodes that were preempted and recreated never came back, so services degraded progressively: background workers on spot instances, reporting services and order allocation stopped completely, and the APIs on existing nodes kept answering but could not scale for load spikes.

    Trigger

    Google upgraded the GKE control plane from v1.32.x to v1.33.2 at the version deprecation deadline, although auto-upgrade was disabled on the node pools.

    Root cause
    Component
    Contributing factor
    Remediation
    • Created a new GKE cluster at v1.33, the version of the forced upgrade
    • Upgraded Istio to 1.27.1 for Kubernetes 1.33 compatibility
    • Updated the cert-manager configuration for Kubernetes 1.33
    • Migrated all production workloads to the new cluster and verified pod scheduling, DNS resolution, PVC mounting and external integrations
    • Decommissioned the broken cluster
    Action items
    • Configure all clusters to use the GKE stable release channel
    • Implement a separate management cluster for Argo CD, monitoring and other control components (Q4 2025)
    • Review spot instance usage for critical workloads and add on-demand fallback pools
    • Document the SRE upgrade procedure: management cluster first, production after a monitoring period of several days
    • Document a Kubernetes, Istio and cert-manager compatibility matrix
    • Create an automated upgrade testing pipeline
    • Reserve static IPs for quick migrations
    • Pin versions of Istio, cert-manager, CSI and DNS addons
    • Stay current with stable releases and regularly check GKE alerts and announcements to avoid deprecation deadlines
    Lessons

    GKE upgrades the control plane at a version's deprecation deadline even when auto-upgrade is disabled, so staying inside the supported version window is how to avoid a forced upgrade. A control plane upgrade can leave existing nodes healthy while every new node fails, and spot nodes that cannot rejoin after preemption turn this into cascading failures. Relying heavily on spot instances for critical workers turned a node join failure into a progressive outage. Kubernetes upgrades have to be planned together with dependent components such as Istio and cert-manager, and without a standby cluster on the same provider there was no immediate failover; the only recovery left was building a new cluster.

  4. Symptoms

    Creating or scaling a node pool on AKS 1.31.8 failed: the VMSS instances never finished provisioning. This started after planned maintenance moved the node image from 202507.* to 202508.*, in a cluster where nodes must send all outbound traffic through an internal HTTP/HTTPS proxy and direct egress is blocked. It happened with both Ubuntu and AzureLinux images.

    Trigger

    A node image auto-upgrade from 202507.* to 202508.* during planned maintenance, on clusters whose Kubernetes patch version was not pre-cached in the new image.

    Root cause
    Component
    Contributing factor
    Detection

    The customer saw VMSS instance provisioning fail with a vmssCSE error in the VMSS activity logs and reported it as a GitHub issue.

    Remediation
    • The customer pinned the node image to a 202507.* snapshot on clusters running 1.31.8
    • The customer upgraded clusters to AKS 1.31.9 or 1.31.10, whose binaries are cached in the 202508.* images
    • The AKS team hot-patched VHD 20250811 so the proxy configuration is used for uncached binary downloads and made it globally available in public regions on 2025-09-04; it also announced the hotfix for VHD 20250820
    • The AKS team told users to reimage their nodes with az aks nodepool upgrade --node-image-only to pick up the hotfixed image
    Action items
    • Apply the proxy fix in all future VHDs
    Lessons

    A bootstrap path that runs only when an artefact is missing from a cache is easy to break without noticing: here only clusters on Kubernetes versions not pre-cached in the node image ever downloaded binaries, so only they met the proxy regression. Testing node provisioning behind a mandatory egress proxy, on older patch versions as well as the newest, would exercise that path. For clusters with restricted egress, pinning the node image or moving to a Kubernetes version cached in the image were both quick workarounds while the fix was shipped.

  5. Symptoms

    At 13:42 UTC on 19 May 2025, RebelMouse's monitoring tools reported a higher error rate and degraded performance across services. A routine reroll of the EKS nodes had started 27 minutes earlier, at 13:15 UTC.

    Trigger

    At 13:15 UTC RebelMouse started its regular reroll of EKS nodes to apply security patches. The planned, automatic termination of an EC2 instance terminated one of the CoreDNS pods.

    Root cause
    Component
    Contributing factor
    Detection

    Monitoring tools detected an increased error rate and degraded service performance at 13:42 UTC, and the tech team started investigating at 13:44 UTC.

    Remediation
    • rescheduled the affected CoreDNS pod onto a new EC2 instance
    • scaled up the CoreDNS deployment to more replicas so DNS load was spread evenly across all pods
    Action items
    • Add scale-in protection so CoreDNS pods are not terminated unexpectedly during peak load
    • Review the CoreDNS configuration so that vertical scaling of the pods works
    • Hold regular capacity reviews so the CoreDNS deployment is provisioned for peak load
Check your cluster for this

These 36 cases involve Node pool and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing

Faulty deployment5 cases

  1. IL-0166 A compute host update removed the credential parser used to decode StackScripts, so new Linodes and every new LKE and LKE-E node failed to boot and autoscaling and node recycling failed in all regions
    Linode2026
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down
  3. IL-0163 An API change that slipped through a gap in automated testing made LKE clusters resize to the wrong number of nodes and added billable worker nodes to customer accounts
    Linode2023
  4. IL-0164 An incremental Linode Kubernetes Engine production update that was missing changes from the previous release made cluster upgrades and node additions fail silently
    Linode2022
  5. IL-0149 Upgrades of AKS clusters on Virtual Machine Scale Sets failed with a 'platform image is not available' error after a service update left a backend service unhealthy

Certificate or credential expiry2 cases

  1. IL-0158 An expired credential caused authentication failures that stopped LKE and LKE-E from deploying clusters and nodes in all regions, which also blocked node recycling and cluster autoscaling
    Linode2026
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect

Breaking change in an upgrade1 case

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours

Software defect4 cases

  1. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  2. IL-0078 Enabling EKS secrets encryption with KMS through Terraform removed worker node IAM permissions and took down all ZenML Pro workspaces
    ZenML2025
  3. IL-0161 A faulty earlier API update made new LKE cluster provisioning in Toronto time out for three days, leaving clusters with no node pools or the wrong number of nodes
    Linode2024
  4. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes

Configuration change6 cases

  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours
  2. IL-0019 An EKS Terraform module upgrade shrank node root disks from 100 GB to 20 GB and image pulls failed with no space left on device
  3. IL-0017 AWS VPC CNI stopped allocating pod IP addresses on six nodes of the live cluster, leaving new pods in ContainerCreating
  4. IL-0091 Changing the worker node instance type through Terraform recycled all nodes at once and deleted users' production pods together
  5. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  6. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Operator error2 cases

  1. IL-0018 A Docker Hub password rotation left EKS nodes and Concourse locked out of Docker Hub and unable to pull images
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage3 cases

  1. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021
  3. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA