  1. Symptoms

    At 16:00 CEST a developer reported in the #ask-platform Slack channel that a deployment to the Prelive cluster was failing, and a second report followed at 16:06.

    Trigger

    Roughly two to three days earlier, the CentOS repository mirror was restructured and container-selinux-2.68-1.el7.noarch.rpm moved, which made the static download URL hardcoded in kops nodeup invalid.

    Root cause
    Component
    Contributing factor
    Detection

    Developers asked for help in the #ask-platform Slack channel because their deployments were failing.

    Remediation
    • downloaded the package by hand on the Prelive nodes so their bootstrap could finish
    • changed the cluster AMI from Amazon Linux 2 to Debian and applied it to all clusters
    Action items
    • Create an alert that shows when nodes cannot join the cluster, possibly from information the cluster autoscaler already has
    • Document the external dependencies of node startup and look for ways to reduce them
    • Change the AMI back to Amazon Linux 2 Minimal once kops fixes the issue
    • Document node troubleshooting better: what happens during bootstrap and where the logs are
    Lessons

    Applying cluster changes through kops and Jenkins worked well, and troubleshooting quickly showed that the failing deployments came from missing cluster capacity. What went wrong was that nobody noticed, over a long period, that some autoscaling groups held more worker instances than Kubernetes had nodes. The team was lucky that no large number of production spot instances was terminated during the problem and that it was noticed during office hours.

  2. Symptoms

    On the evening of a long-overdue upgrade of a loveholidays production GKE cluster from 1.10.X to 1.12.5-gke.10, planned to take 2 to 2.5 hours, the master upgrade and the first two 7-node NodePools went smoothly. After that the NodePool upgrades slowed to a crawl. Each node is cordoned, drained and upgraded in turn. Even a 14-node cluster at about 5 minutes per node took over an hour, and with about 100 more nodes to go, some of them taking over 15 minutes to drain, the sequential drains were too slow to finish at a reasonable hour.

    Trigger

    A manual upgrade of the GKE masters and NodePools from 1.10.X to 1.12.5-gke.10, two versions at once, on 19 March 2019; GKE's release notes of 14 March had already said that version was no longer available for new clusters or master upgrades because masters showed elevated error rates, but it could still be selected.

    Root cause
    Component
    Contributing factor
    Detection

    The slow drains, zombie nodes and stuck NodePool were seen by the engineer running the upgrade; the broken Ingress was noticed after the upgrade and explained by Google support; the HPA problem was noticed the next day.

    Remediation
    • drained the remaining NodePool nodes ahead of the upgrade with kubectl drain --ignore-daemonsets --delete-local-data
    • deleted the zombie instances from the managed instance group with gcloud compute instance-groups managed delete-instances
    • cancelled the stuck UPGRADE_NODES operation with gcloud beta container operations cancel
    • used kubectl port-forward in place of the broken internal Ingresses
    • scaled down the older of two active ReplicaSets, or triggered a dummy deployment, to bring the HPA back
    Action items
    • Alert when a HorizontalPodAutoscaler is at 70% and at 100% of its capacity
    • Alert when a deployment has had two active ReplicaSets for 30 minutes and for 60 minutes
    • Re-evaluate termination grace periods that were set to arbitrary large values
    • Read the GKE release notes before every cluster upgrade
    • Use auto-upgrade in non-production environments, and manual cluster upgrades with automatic node upgrades in production
    • Keep environments as identical as possible, including resource names
    Lessons

    Read the release notes before upgrading: the target version had been withdrawn five days earlier. Drain time depends on pod configuration, so emptyDir volumes, long grace periods and missing disruption budgets turn a NodePool upgrade into hours. Pre-production only catches problems like the ingress bug if it matches production down to resource names. Auto-upgrades in non-production surface problems early, and a mix of manual cluster upgrades and automatic node upgrades in production keeps clusters current without much effort.

  3. Symptoms

    While the old nodes of a GKE cluster were being drained to move workloads to a newly created node pool, none of the services in the cluster could be reached through ingress-nginx any more.

    Trigger

    Cordoning and draining the old node pool removed those nodes from the GCP load balancer backend while the ingress-nginx pods were still running on them.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed during the drain that no service in the cluster was reachable through ingress-nginx.

    Remediation
    • deleted the nginx-ingress-controller pods still running on the old nodes so they were rescheduled on the new, ready nodes
    Lessons

    With externalTrafficPolicy: Local, the load balancer can only reach nodes that run an ingress pod, and cordoned nodes leave the load balancer backend immediately; if the ingress pods stay behind on cordoned nodes, all ingress traffic stops. Before any change that might touch traffic, look twice into the documentation.

  4. Symptoms

    A Kubernetes cluster went down after one CronJob kept failing and its pods piled up. Because each failed run kept restarting instead of being replaced by the next one, the pods accumulated into the thousands. The speaker's arithmetic for a job scheduled every minute that fails for three days is 4,320 restarting pods.

    Trigger

    A CronJob kept failing.

    Root cause
    Component
    Contributing factor
    Lessons

    When deploying a CronJob, set its concurrency policy to Replace or Forbid; with the default, failing runs accumulate and restart together. An application should handle a missing dependency with probes and bounded back-off rather than crash in a loop, which also keeps it from hammering a dependency that is already struggling.

Check your cluster for this

These 36 cases involve Node pool and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause9

Capacity exhaustion11 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  3. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  4. IL-0082 Losing one CoreDNS pod during a planned EKS node reroll overloaded the remaining CoreDNS pods, causing DNS timeouts and errors across multiple services at RebelMouse
  5. IL-0099 User servers on 2i2c's Earthscope hub took over 15 minutes to start and kernels were killed during a workshop, because a profile option guaranteed 8 GB of memory with no limit on 32 GB nodes
    2i2c2025
  6. IL-0027 All CoreDNS pods landed on one node, the node ran out of memory, and DNS for the whole service went down
  7. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  8. IL-0070 Critical pods on core nodes evicted when Prometheus began scraping about 200 nodes after a dask-gateway scale-up
    2i2c2023
  9. IL-0094 Student pods filled the shared nodes of a JupyterHub cluster and starved the hub's core pods, freezing the hub
    2i2c2020
  10. IL-0013 The conntrack table filled up on downsized GKE nodes and a high-traffic aggregation proxy saw climbing connection resets
  11. IL-0015 A GKE cluster's /16 pod address range ran out at 256 nodes, leaving new pods Pending and node scale-ups failing

Faulty deployment5 cases

  1. IL-0166 A compute host update removed the credential parser used to decode StackScripts, so new Linodes and every new LKE and LKE-E node failed to boot and autoscaling and node recycling failed in all regions
    Linode2026
  2. IL-0020 During an EKS 1.30 upgrade the descheduler tried to reschedule every pod on the cordoned nodes at once and production workloads went down
  3. IL-0163 An API change that slipped through a gap in automated testing made LKE clusters resize to the wrong number of nodes and added billable worker nodes to customer accounts
    Linode2023
  4. IL-0164 An incremental Linode Kubernetes Engine production update that was missing changes from the previous release made cluster upgrades and node additions fail silently
    Linode2022
  5. IL-0149 Upgrades of AKS clusters on Virtual Machine Scale Sets failed with a 'platform image is not available' error after a service update left a backend service unhealthy

Certificate or credential expiry2 cases

  1. IL-0158 An expired credential caused authentication failures that stopped LKE and LKE-E from deploying clusters and nodes in all regions, which also blocked node recycling and cluster autoscaling
    Linode2026
  2. IL-0113 The managed GKE control plane of Webhook Relay's main cluster failed because its API server certificates had never been rotated, and a manual credential rotation reported success without taking effect

Breaking change in an upgrade1 case

Organisation
  1. IL-0101 After Google forced a GKE control plane upgrade to 1.33.2 at a deprecation deadline, no new node could initialise, so autoscaling and spot node replacement stopped for 15 hours

Software defect4 cases

  1. IL-0147 AKS nodes behind an HTTP proxy failed to provision with CSE exit code 31 on 202508 node images, because a refactoring stopped the proxy from being used when downloading uncached Kubernetes binaries
  2. IL-0078 Enabling EKS secrets encryption with KMS through Terraform removed worker node IAM permissions and took down all ZenML Pro workspaces
    ZenML2025
  3. IL-0161 A faulty earlier API update made new LKE cluster provisioning in Toronto time out for three days, leaving clusters with no node pools or the wrong number of nodes
    Linode2024
  4. IL-0190 Cortex distributors kept a stuck connection to a dead etcd leader after a Kubernetes upgrade terminated its node, failing writes to Hosted Prometheus for 12 minutes

Configuration change6 cases

  1. IL-0114 An unpinned AWS VPC CNI plugin was updated automatically during a capacity expansion, leaving new pods Pending without IP addresses and stopping CoW Protocol settlements for about 3.5 hours
  2. IL-0019 An EKS Terraform module upgrade shrank node root disks from 100 GB to 20 GB and image pulls failed with no space left on device
  3. IL-0017 AWS VPC CNI stopped allocating pod IP addresses on six nodes of the live cluster, leaving new pods in ContainerCreating
  4. IL-0091 Changing the worker node instance type through Terraform recycled all nodes at once and deleted users' production pods together
  5. IL-0109 A retried node rollover on a DFDS EKS cluster set the Auto Scaling group back to 15 instances, and the default termination policy removed every healthy worker node, leaving the cluster with no nodes
    DFDS2023
  6. IL-0055 A failing CronJob with the default concurrency policy piled up thousands of restarting pods and took down a cluster
    Target2018

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0039 New Kubernetes worker nodes could not join any cluster because a package URL hardcoded in kops nodeup broke

Operator error2 cases

  1. IL-0018 A Docker Hub password rotation left EKS nodes and Concourse locked out of Docker Hub and unable to pull images
  2. IL-0054 All ingress traffic lost while draining a GKE node pool because the load balancer only targeted new nodes without ingress-nginx pods

Cloud provider outage3 cases

  1. IL-0096 A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)
    2i2c2022
  2. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021
  3. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA