  1. Symptoms

    At 11:59AM CDT on Friday 28 August 2020, Basecamp's Ops team received a flood of alerts from PagerDuty, Nagios and Prometheus. Monitoring showed that the newer of the two metro links between the data centers in Ashburn, VA and Chicago, IL had been lost for about 20-30 seconds, and BC3 kept responding slowly after the link came back.

    Trigger

    Both redundant metro links between Basecamp's Ashburn and Chicago data centers dropped for short periods; monitoring showed the newer link down for about 20-30 seconds.

    Root cause
    Component
    Contributing factor
    Detection

    A flood of alerts from PagerDuty, Nagios and Prometheus, with monitoring showing the lost metro link. A lingering alert for one Redis DB instance later pointed to the replication problem.

    Remediation
    • Turned chat off at the load balancer layer so the rest of BC3 could stabilise
    • Restarted Redis on the replica that was stuck in the resynchronization loop
    Action items
    • Make the documented Redis configuration changes for the known replication issue
    • Make concrete plans to remove the shared physical path under the two metro links
    • Prove the failover systems in production at peak load
    • Make explicit room for post-incident follow-up work and push other work out
    Lessons

    Planned redundancy and live testing had given Basecamp a false sense of security, especially at peak load: moving between redundant network links or shifting load across data centers should work without issue, and Basecamp would rather find out in a controlled test with the full team ready. The follow-up from an outage needs urgency and explicitly cleared time, not just a place on a list.

  2. Symptoms

    On 16 July 2020 between 13:26 and 13:48 UTC, DNS queries to two nodes of Gandi's LiveDNS platform failed with a timeout, and retries against the other name servers of a domain failed as well. The status page reported impact for FR customers.

    Trigger

    A software bug in Gandi's DNS server software triggered a fault and stopped the server on two LiveDNS nodes.

    Root cause
    Component
    Contributing factor
    Detection

    Monitoring alerts fired on the DNS servers, but they were first read as false positives among the noise from an earlier internal network incident.

    Action items
    • Fix the way a node is disabled when its DNS server is not working correctly
    • Fix the node configuration and add monitoring so that no node announces several clusters
    • Rework monitoring and internal training and organisation
    • Deploy the fix for the bug in the DNS server software