IL-0509SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnetSourceHut2024- Symptoms
At about 06:00 UTC on 10 January 2024, SourceHut's monitoring raised the alarm as a layer 3 DDoS attack hit its infrastructure in the PHL datacenter, and at about 09:00 UTC SourceHut lost all access to its PHL network. PHL was the primary datacenter, and the network became unreachable for SourceHut staff and the general public alike.
- Trigger
A layer 3 DDoS attack against SourceHut's PHL infrastructure that began at about 06:00 UTC on 10 January 2024 and broadened to more of the PHL subnet on 11 January.
- Root cause
- Component
- Contributing factor
- Detection
SourceHut's monitoring systems noticed that something was wrong and raised the alarm from about 06:00 UTC on 10 January.
- Remediation
- Got Cogent, through the colocation provider, to narrow the null route from the /24 to the targeted /32, which mostly restored service on 10 January
- Moved DNS to an external DNS provider
- Brought up a new primary database in AMS
- Restored backups from FRE to AMS
- Applied the difference between production data and the last backups by hand
- Provisioned a new mail system and configured the mail services for it
- Set up an OVH box that NATs traffic through OVH's DDoS-resistant network to the production subnet in AMS
- Used a temporary subnet from the PHL network provider for out-of-band access to the PHL servers
- Served pages.sr.ht through an out-of-band link to PHL while its object storage was migrated
- Emailed pages.sr.ht users whose apex records pointed at the PHL subnet with instructions
- Ran build workers on dedicated bare-metal OVH servers
- Action items
- Provision a new standby database
- Configure backups from AMS to FRE
- Install a new monitoring system
- Retire the PHL datacenter installation and ship its servers to AMS
- Move build service back onto SourceHut-operated servers once the build servers are shipped from PHL to AMS
- Research and implement a way to run SourceHut in an on-premise Kubernetes cluster
- Plan a second production-ready datacenter to load balance against, able to take over full service in a datacenter outage
- Lessons
The operational plans SourceHut kept for failures up to the loss of a whole datacenter proved important in this incident. The incident exposed a known shortcoming in redundancy and resilience that the team was working on but had not finished, and the response of the upstream network to the attack did more damage than anything else.
- Symptoms
On 10 January 2023 at 16:37 UTC Icinga reported "BGP status on cr3-eqsin is CRITICAL: BGP CRITICAL - AS1299/IPv6: Active - Telia, AS1299/IPv4: Active - Telia", and from 16:45 the hosts in Wikimedia's eqsin site went DOWN with "PING CRITICAL - Packet loss = 100%". Users normally directed to eqsin, mostly in the APAC region, could only read Wikipedia pages already cached in eqsin.
- Trigger
Planned maintenance by the transport provider took down eqsin's second transport link while the first was still down from a long fiber cut.
- Root cause
- Component
- Contributing factor
- Detection
Automated monitoring: Icinga BGP status alerts for cr3-eqsin at 16:37 and cr2-eqsin at 16:44, followed by a flood of host-down alerts and three pages at the same time.
- Remediation
- Depooled eqsin from DNS
- Repooled eqsin
- Action items
- Create a backup GRE tunnel for eqsin (T327265)
- Ensure the long-down transport link comes back up properly once it is fixed (T322529)
- Automatically parse maintenance notifications and alert on conflicting maintenance (T230835)
- Lessons
The site was depooled quickly, and "depool first, investigate later" was the right attitude. A flood of host-down alerts usually means a network problem. eqsin stayed too long on a single working transport link, SREs did not catch that the downtime of the two transport links overlapped, and the provider's planned maintenance was not recorded in a task or reminder.
IL-0255Basecamp's two redundant links between data centers dropped together and a Redis replica resync loop stalled chat37signals2020- Symptoms
At 11:59AM CDT on Friday 28 August 2020, Basecamp's Ops team received a flood of alerts from PagerDuty, Nagios and Prometheus. Monitoring showed that the newer of the two metro links between the data centers in Ashburn, VA and Chicago, IL had been lost for about 20-30 seconds, and BC3 kept responding slowly after the link came back.
- Trigger
Both redundant metro links between Basecamp's Ashburn and Chicago data centers dropped for short periods; monitoring showed the newer link down for about 20-30 seconds.
- Root cause
- Component
- Contributing factor
- Detection
A flood of alerts from PagerDuty, Nagios and Prometheus, with monitoring showing the lost metro link. A lingering alert for one Redis DB instance later pointed to the replication problem.
- Remediation
- Turned chat off at the load balancer layer so the rest of BC3 could stabilise
- Restarted Redis on the replica that was stuck in the resynchronization loop
- Action items
- Make the documented Redis configuration changes for the known replication issue
- Make concrete plans to remove the shared physical path under the two metro links
- Prove the failover systems in production at peak load
- Make explicit room for post-incident follow-up work and push other work out
- Lessons
Planned redundancy and live testing had given Basecamp a false sense of security, especially at peak load: moving between redundant network links or shifting load across data centers should work without issue, and Basecamp would rather find out in a controlled test with the full team ready. The follow-up from an outage needs urgency and explicitly cleared time, not just a place on a list.
These 3 cases involve BGP routing and Backbone network (WAN). kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Dependency failure3 cases
- Component
- Contributing factor
- Organisation
IL-0509SourceHut was down for 170 hours after a DDoS led its upstream network to null-route the PHL datacenter's subnetSourceHut2024IL-0267Wikimedia's eqsin cache site went unreachable when both of its transport links to the core data centers were downIL-0255Basecamp's two redundant links between data centers dropped together and a Redis replica resync loop stalled chat37signals2020