  1. Symptoms

    On 2025-03-12 from 10:58 UTC, alerts for high backend response times came in, and the MediaWiki deployments mw-api-int, mw-parsoid and mw-jobrunner, which serve MediaWiki for non-user-facing purposes, showed high latency and database errors. The External Storage cluster, whose hosts store the compressed text of wiki page revisions, had a sharp rise in load and connections. The same happened again on 2025-03-13 from 11:15 UTC.

    Trigger

    At 10:44 UTC on 12 March a Scap deployment of the PHP 8.1 rollout for mw-api-int, mw-parsoid and mw-jobrunner was run with the flag -Dbuild_mw_container_image:False; the rollout was deployed with Scap again at 11:15 UTC on 13 March.

    Root cause
    Component
    Contributing factor
    Detection

    Alerts for high backend response times started at 10:58 UTC on 12 March, 14 minutes after the Scap deployment; 2 on-call engineers were paged. The MediaWikiMemcachedHighErrorRate alert that pointed at the cause fired only briefly because its log pipeline was overloaded.

    Remediation
    • Deployed a patch to cirrus-streaming-updater that reduced SUP parallelism
    • Reduced the concurrency of the categoryMembershipChange job in changeprop-jobqueue
    • On 12 March, reverted 1126607 and 1126650 and re-ran Scap
    • On 13 March, rolling-restarted changeprop-jobqueue
    • Rolling-restarted mw-api-int
    • Disabled the categorymembership job in changeprop-jobqueue
    • Reverted 1127476 and 1127478
    • Redeployed mw-api-int to pick up the revert
    • Increased the number of mw-api-int replicas
    • Redeployed mw-jobrunner to pick up the revert
    • Redeployed mw-parsoid to pick up the revert
    Action items
    • Reduce the number of messages sent through channel:Memcached during failures
    • Add helm rollback functionality to Scap
    • Decide whether Scap should update helmfile-defaults when -Dbuild_mw_container_image:False is set
    • Consider removing envvars.inc from MediaWiki images
    • Consider "Why" dashboards that give an overview of a group of related components together with relevant links to follow
    • Coordinate incident responders better
    • Be able to work with MediaWiki developers during incidents
    Lessons

    The write-up puts the weight not on the technical root cause but on why the team could not see, even after the 12 March incident, that three MediaWiki deployments were running without Memcached. Alert dashboards showed what was happening, such as many busy PHP workers, but not why; dashboards linking components that affect each other, such as SQLBlobStore keys and External Storage, would have helped. The alert that pointed in the right direction did not stay firing and would probably have been lost among 78 others. The incident coordinator could not tell who was working on what or who had joined or left, the channels were noisy, the external impact was judged more critical than it was, and trace.wikimedia.org was not used although it might have helped.

  2. Symptoms

    At 11:59AM CDT on Friday 28 August 2020, Basecamp's Ops team received a flood of alerts from PagerDuty, Nagios and Prometheus. Monitoring showed that the newer of the two metro links between the data centers in Ashburn, VA and Chicago, IL had been lost for about 20-30 seconds, and BC3 kept responding slowly after the link came back.

    Trigger

    Both redundant metro links between Basecamp's Ashburn and Chicago data centers dropped for short periods; monitoring showed the newer link down for about 20-30 seconds.

    Root cause
    Component
    Contributing factor
    Detection

    A flood of alerts from PagerDuty, Nagios and Prometheus, with monitoring showing the lost metro link. A lingering alert for one Redis DB instance later pointed to the replication problem.

    Remediation
    • Turned chat off at the load balancer layer so the rest of BC3 could stabilise
    • Restarted Redis on the replica that was stuck in the resynchronization loop
    Action items
    • Make the documented Redis configuration changes for the known replication issue
    • Make concrete plans to remove the shared physical path under the two metro links
    • Prove the failover systems in production at peak load
    • Make explicit room for post-incident follow-up work and push other work out
    Lessons

    Planned redundancy and live testing had given Basecamp a false sense of security, especially at peak load: moving between redundant network links or shifting load across data centers should work without issue, and Basecamp would rather find out in a controlled test with the full team ready. The follow-up from an outage needs urgency and explicitly cleared time, not just a place on a list.