  1. Symptoms

    From 16:27 UTC on 21 August 2025, users connecting to Cloudflare from servers in AWS us-east-1, or receiving connections from Cloudflare there, saw high latency, packet loss and failures to reach origins. Cloudflare's network team was alerted to internal congestion in Ashburn (IAD) at 16:44 UTC.

    Trigger

    At about 16:27 UTC a single customer began sending many requests from AWS us-east-1 to Cloudflare for objects in Cloudflare's cache, doubling the total traffic from Cloudflare to AWS.

    Root cause
    Component
    Contributing factor
    Detection

    Cloudflare's network team was alerted to internal congestion in Ashburn (IAD) at 16:44 UTC, and an incident was raised for customer impact at 17:45 UTC.

    Remediation
    • Rate limited the single customer whose traffic caused the surge
    • Took further traffic engineering actions that fully resolved the congestion
    • Asked AWS to revert its BGP prefix withdrawals, which AWS finished at 20:07 UTC
    Action items
    • Build a mechanism to deprioritise a customer's traffic when it congests the network enough to affect others
    • Speed up the Data Center Interconnect upgrades to add network capacity
    • Work with AWS so the two companies' BGP traffic engineering actions do not conflict
    • Build a traffic management system that gives each customer a network resource budget and automates the manual actions used here
    Lessons

    Cloudflare concludes that it must isolate customers better so that no single customer can take over shared network resources and degrade the platform for others, and that its network needs enough capacity to meet demand. It describes the outage as the result of insufficient network congestion management during an unusual high-traffic event.

  2. Symptoms

    From 11:45 UTC on 30 July 2024, a subset of customers got intermittent connection errors, timeouts and latency spikes when connecting to Microsoft services that use Azure Front Door (AFD) and Azure Content Delivery Network (CDN). The Azure Portal team saw the first service degradation at 11:47 UTC.

    Trigger

    Around 11:45 UTC the Azure network DDoS protection service was disengaging after a routine DDoS mitigation and returning traffic to its default routing to AFD, but the routes at one site in Europe could not be updated because the network control plane could not reach that site during a local power outage.

    Root cause
    Component
    Contributing factor
    Detection

    The Azure Portal team detected service degradation at 11:47 UTC and began to investigate. At 12:10 UTC network monitoring correlated the Portal incident to a network issue at one site in Europe, and networking engineers joined.

    Remediation
    • Rerouted traffic under the standard congestion playbook, which removed most of the impact by 13:58 UTC
    • Ordered the network control plane to reissue its commands to the misbehaving device, which could not be reached
    • Removed the device that kept attracting traffic from the network and scanned the network for other issues
    Action items
    • Add the missing configuration on network devices so a DDoS mitigation issue in one geography cannot spread to another
    • Improve validation and monitoring in the Azure network to detect invalid configurations
    • Improve monitoring for when the DDoS protection service is unreachable from the control plane but still serving traffic