    On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.

    Trigger

    On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.

    Root cause
    Component
    Contributing factor
    Detection

    As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.

    Remediation
    • Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
    • Fixed the control plane's periodic job so idle computes were terminated again
    • Restarted the aws-node DaemonSet several times, each with a temporary improvement
    • Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
    • On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
    • Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
    Action items
    • Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
    • Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
    • Change the architecture to support horizontal scaling
    Lessons

    With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.

  2. Symptoms

    On 21 March 2025, between 21:10 and 21:41 UTC, part of the authentication and authorization requests to Twingate services failed with elevated error rates.

    Trigger

    Twingate saw anomalies in one of its GKE clusters and scaled down the deployments in that cluster to protect the rest of the system, which moved its traffic to the other clusters.

    Root cause
    Component
    Contributing factor
    Detection

    Twingate observed anomalies in one of its GKE clusters at the start of the incident.

    Remediation
    • Reintroduced capacity in the cluster that had been scaled down, so traffic was rebalanced across regions
    Action items
    • Keep working with the cloud provider to find the cause of the unexpected timeouts and of the cluster update's impact
    • Run deployments in all regions with the same number of replicas in the HPA configuration