  1. Symptoms

    At 22:54 UTC on 21 October 2018 GitHub's internal monitoring started alerting on many faults at once. By 23:02 UTC the first responders saw that the replication topologies of many MySQL clusters were in an unexpected state: the Orchestrator API showed topologies made only of servers in the US West Coast data center. When connectivity came back, the application tier had immediately started sending writes to the new West Coast primaries.

    Trigger

    At 22:52 UTC on 21 October, routine maintenance to replace failing 100G optical equipment cut connectivity between GitHub's US East Coast network hub and its primary US East Coast data center for 43 seconds.

    Root cause
    Component
    Contributing factor
    Detection

    GitHub's internal monitoring raised alerts on numerous faults at 22:54 UTC, two minutes after the partition. By 23:02 UTC the first responders had found, by querying the Orchestrator API, that many database clusters had a topology with only US West Coast servers.

    Remediation
    • Locked the internal deployment tooling to stop further changes
    • Paused webhook delivery and GitHub Pages builds to stop jobs writing metadata
    • Restored the affected MySQL clusters from backups into the US East Coast data center and let them replicate from the West Coast
    • Found ways to restore directly from the West Coast to get around the throughput limits of downloading from off-site storage
    • Moved all database primaries back to the US East Coast data center
    • Spread read traffic over additional MySQL read replicas in the US East Coast public cloud so replication could catch up
    • Failed over to the original topology once the replicas were in sync
    • Processed the backlog of webhook events and Pages builds, pausing to raise an internal TTL after about 200,000 webhook payloads were dropped
    Action items
    • Reconcile the writes from the captured MySQL binary logs that were not replicated, automatically where possible and with user outreach otherwise
    • Make sure status updates can be published even when GitHub Pages builds are paused
    • Give more accurate public estimates of the time to repair
    • Configure Orchestrator so it cannot promote database primaries across regional boundaries
    • Move to a status reporting mechanism that shows the status of each component of the platform
    • Serve GitHub traffic from multiple data centers in an active/active/active design with N+1 redundancy at the facility level
    • Test assumptions about the system more proactively
    • Validate failure scenarios systematically, with investment in fault injection and chaos engineering tooling
    Lessons

    Orchestrator did what it was configured to do, but the application tier could not work with primaries on the other side of the country: leader election within one region is generally safe, while the sudden cross-country latency was a major contributing factor. The behaviour emerged from a partition larger than any GitHub had seen. Replication caught up along a power decay curve, not a straight line, so the linear estimates of recovery time were wrong. GitHub concluded that tighter operational controls and faster response are not enough on their own and that failure scenarios have to be validated before they happen.

  2. Symptoms

    On Monday, September 10th, 2012, during a schema migration, the health checks on GitHub's MySQL master failed and Percona Replication Manager moved the 'active' role to another node of the new three-node cluster. That node's InnoDB buffer pool was cold and it performed poorly, its health checks failed in turn, and the role failed back to the original server. GitHub.com went down.

    Trigger

    A schema migration on Monday, September 10th put more load on the master database than earlier migrations had, and Percona Replication Manager's health checks on the master failed.

    Root cause
    Component
    Contributing factor
    Detection

    On the morning of September 11th, a developer told the operations team that the 'standby' node was returning incorrect query results.

    Remediation
    • Enabled Pacemaker's maintenance-mode so no health checks or automatic failovers ran, and let the buffer pool warm
    • Powered off the out-of-date node 'c' to end the partition
    • Stopped Pacemaker and Heartbeat on nodes 'a' and 'b' and started them on node 'a' only
    • Started MySQL on node 'a' in the active role
    • Removed the events leaked to wrong dashboards and audited the wrongly routed repositories
    • Contacted the owners of the exposed private repositories
    Action items
    • Change the Pacemaker configuration so the active database role fails over only when an operations engineer starts it
    • Find a way to warm the InnoDB buffer pool of slave databases so failovers do not hurt performance
    • Audit the Pacemaker and Heartbeat stack, focusing on the code path behind the segfault
    • Run hardware tests on the server where the segfault happened
    Lessons

    GitHub concluded that automated failover is not the right strategy for its primary production database: for every failover in this incident, any member of the operations team would have said it should not happen. Failovers that must happen, in an emergency or during maintenance, should not hurt performance.

Check your cluster for this