Cases4 cases

1 to 4 of 4

  1. Symptoms

    On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.

    Trigger

    At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.

    Root cause
    Component
    Contributing factor
    Detection

    Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.

    Remediation
    • Fixed both VPC route reflectors by manual action
    Action items
    • Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
    • Run different software versions on the route reflectors so a single bug cannot stop several instances
    • Investigate the software issue that left the route reflectors in a stale state
  2. Symptoms

    From 19:50 US/Pacific on 4 December 2023, Cloud Bigtable customers in us-central1 saw higher latency and a low level of connection errors, affecting about 0.06% of Bigtable dataplane requests. Automated monitoring first detected the problem at 23:35.

    Trigger

    A change that caused an isolation failure on the machines running Cloud Bigtable servers.

    Root cause
    Component
    Contributing factor
    –
    Detection

    Automated monitoring detected the problem at 23:35 US/Pacific on 4 December 2023.

    Remediation
    • Redirected some traffic away from a subset of the affected machines
    • Rolled back the change that triggered the isolation failure
    Action items
    • Put controls in place to prevent a recurrence
  3. Symptoms

    Shortly after incident.io moved its infrastructure fully into Google Cloud, the application saw a larger-than-normal number of Postgres connection timeouts, and new database connections per second were in the hundreds, spiking up and down. At the same time, the memcached instance used for transient data and faster API responses had sporadic connection timeouts.

    Trigger

    After the move to Google Cloud, the application opened hundreds of new Postgres connections per second, and an accidental database join made it send thousands of duplicate calls to an external third party in parallel.

    Root cause
    Component
    Contributing factor
    Detection

    An incident was declared when the number of Postgres connection timeouts rose above normal. The remaining cache timeouts were traced through the logs of the Kubernetes node that served an affected request, the request's trace and the node's metrics.

    Remediation
    • Doubled the maximum Postgres connection lifespan from 15m to 30m
    • Made the Postgres connection pools static so they always keep N connections open
    • Raised the memcache client's MaxIdleConns from 2 to 20
    • Moved temporarily from Google's hosted memcached to a memcached inside the Kubernetes cluster
    • Shipped the fix for the accidental database join that made thousands of duplicate external calls
    Action items
    • Set more sensible concurrency limits for outbound network calls
    Lessons

    Network timeouts are not always local to one request or pod: when they appear, the whole activity of the node, including other pods on it, needs to be checked. Staying within a provider's rate limits does not keep outbound calls from affecting a node, so outbound network calls need more sensible concurrency limits.

  4. Symptoms

    On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.

    Trigger

    At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.

    Root cause
    Component
    Contributing factor
    Detection

    At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.

    Remediation
    • Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
    • Moved API traffic that could use read replicas to the secondary data center by hand
    • Sent authentication calls fully back to the primary data center when the dashboard got worse
    • Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
    • Ramped the turned-down services back up so asynchronous processing could catch up
    Action items
    • Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
    • Redesign the user sessions system so dashboard traffic can be steered between data centers
    • Change the auto-remediation configuration so a database replica is not promoted so quickly
    • Tune each system involved to be more resilient to failures of its dependencies
    Lessons

    Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.

Check your cluster for this