Applied filters ComponentDatabase replicationFactorAutomation amplificationClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases8 cases

1 to 5 of 8

  1. Symptoms

    From the evening of 27 September 2026 (UTC), InfluxDB Cloud customers in Azure West Europe saw slow queries and query timeouts, and a query queue depth alert fired at 22:58 UTC. Writes were accepted the whole time, but new data on some partitions could not be queried right away.

    Root cause
    Component
    Contributing factor
    Detection

    A query queue depth alert fired at 22:58 UTC on 27 September and an incident was opened.

    Remediation
    • Doubled query-layer capacity
    • Restarted stuck storage pods one at a time
    • Raised the readiness probe timeout and rolled it out fleet-wide
    • Doubled recovery concurrency after a restart
    • Raised the cleanup timeout to 24 hours, which stopped the forced restarts
    • Raised each storage pod's resource request so each host held fewer pods, doubling page cache memory and disk throughput per pod
    Action items
    • Add warning alerts for page-fault rate, cache coverage, disk reads on storage volumes and query abandonment
    • List major page faults in the runbooks as a leading indicator of storage performance degradation, with the relief valves that can be tuned
    • Keep tracking down the storage-engine reference leak
    • Move the disk check out of the health path
    Lessons

    Because the storage process uses little memory and the page cache takes what is left, a page cache too small for the data being queried does not show up as memory pressure on the usual memory metrics. InfluxData now treats major page faults as a leading indicator of storage performance degradation and alerts on cache pressure before customers see it.

  2. Symptoms

    On 25 February 2025, regional Upstash Redis databases in AWS eu-west-1 slowed down after a maintenance update, with very high CPU load on databases that have a replica in that region. Latency stayed high until about 21:23 UTC, even after the affected databases were unthrottled at 15:06 UTC.

    Trigger

    A maintenance update to the regional Upstash Redis databases in AWS eu-west-1.

    Root cause
    Component
    Contributing factor
    Remediation
    • Added more resources to the regional eu-west-1 cluster
    • Unthrottled the affected databases at 15:06 UTC and enabled more throughput
    Action items
    • Deploy a fix that stops regional databases from starting unnecessary full synchronisations
    • Contact regional database users about migrating to Upstash Global, which does not have this issue
  3. Symptoms

    At 9:34 UTC on November 23, 2022, RevenueCat started moving traffic from its Aurora PostgreSQL 10.x cluster to a new Aurora PostgreSQL 14.x cluster. By 9:39 UTC all traffic was on the new cluster, latency was bad, and the RevenueCat dashboard and the endpoints used by the RevenueCat SDK stopped working.

    Trigger

    At 9:34 UTC production traffic was switched from the Aurora PostgreSQL 10.x cluster to the new Aurora PostgreSQL 14.x cluster, before ANALYZE had run on its largest tables.

    Root cause
    Component
    Contributing factor
    Detection

    At 9:39 UTC, with all traffic on the new cluster, latency looked bad and the infrastructure team began to investigate.

    Remediation
    • Added a statement timeout to the database user so queries could not hold a connection too long
    • Shed 90% of traffic by returning 503s from the load balancer
    • Dropped indexes that the planner was using wrongly and that were not needed
    • Stopped accepting Apple webhooks for a time
    • Rolled out a release without New Relic to stop its EXPLAIN queries
    • Ran ANALYZE by hand on the biggest tables
    • Raised the values of the affected primary key sequences with a prepared script
    • Stopped the integration event dispatcher by hand
    • Replayed the webhooks that were dispatched but not recorded
    • Restored integration event dispatching, ETLs and other non-web server jobs
    Action items
    • Consider change freezes during business-critical periods
    • Explain better how the SDK behaves during backend outages
    • Tell customers about maintenance and outages in the developer dashboard and by direct email to technical contacts
    • Replay a subset of write traffic in migration dry runs to mimic the cutover
    • Move costly processes to asynchronous work to keep the API fast and stable
    • Re-evaluate table indexes, including unused ones the database may choose for queries
    • Show the load of each endpoint and system in the database dashboards
    • Involve support and customer communications staff during outages
    Lessons

    The new cluster had not been analyzed, and the tests missed it because the test cluster had been up long enough to gather statistics. Dry runs replayed no write traffic, on the belief that writes are simpler than reads, and the team assumed sequence state was replicated with the data. Rolling back at the start would have been better than fixing forward. The migration, timed to finish before Thanksgiving and Black Friday, should have been delayed until the week after, because the US had entered a sensitive period and part of the US support team was already on holiday.

  4. Symptoms

    On 2 November 2020 the Cloudflare API and dashboard were degraded for six hours and 33 minutes. The success rate of API queries dropped at times to 75%, and the dashboard was up to 80 times slower than normal, while Cloudflare's edge network kept working.

    Trigger

    At 14:43 UTC a network switch in a control plane data center partly failed: it kept LACP and BGP running but stopped forwarding some packets, and it recovered on its own six minutes later.

    Root cause
    Component
    Contributing factor
    Detection

    At 14:43 UTC alerts fired because the misbehaving switch was unreachable to pings. Engineers then saw that the primary authentication database was overwhelmed.

    Remediation
    • Shed load from the primary authentication database by slowing SSL certificate pushes to the edge, emails and other features
    • Moved API traffic that could use read replicas to the secondary data center by hand
    • Sent authentication calls fully back to the primary data center when the dashboard got worse
    • Rebuilt the first database replica, which put itself back into service at 21:20 UTC and returned performance to normal
    • Ramped the turned-down services back up so asynchronous processing could catch up
    Action items
    • Remove the cluster management limitation that requires rebuilding all replicas after a primary is promoted
    • Redesign the user sessions system so dashboard traffic can be steered between data centers
    • Change the auto-remediation configuration so a database replica is not promoted so quickly
    • Tune each system involved to be more resilient to failures of its dependencies
    Lessons

    Every system in the chain had redundancy and none failed completely; each only degraded, which made the chain of events much harder to model and foresee. Automating replica promotion so that it could trigger on a minute's notice had been a point of pride, but for at least one database a fast promotion can do more harm than the failure it answers. Most general-purpose cluster managers use Raft or Paxos rather than Byzantine fault tolerant protocols, accepting a rare failure mode in exchange for a protocol that is simpler to implement correctly and debug.

  5. Symptoms

    At 22:54 UTC on 21 October 2018 GitHub's internal monitoring started alerting on many faults at once. By 23:02 UTC the first responders saw that the replication topologies of many MySQL clusters were in an unexpected state: the Orchestrator API showed topologies made only of servers in the US West Coast data center. When connectivity came back, the application tier had immediately started sending writes to the new West Coast primaries.

    Trigger

    At 22:52 UTC on 21 October, routine maintenance to replace failing 100G optical equipment cut connectivity between GitHub's US East Coast network hub and its primary US East Coast data center for 43 seconds.

    Root cause
    Component
    Contributing factor
    Detection

    GitHub's internal monitoring raised alerts on numerous faults at 22:54 UTC, two minutes after the partition. By 23:02 UTC the first responders had found, by querying the Orchestrator API, that many database clusters had a topology with only US West Coast servers.

    Remediation
    • Locked the internal deployment tooling to stop further changes
    • Paused webhook delivery and GitHub Pages builds to stop jobs writing metadata
    • Restored the affected MySQL clusters from backups into the US East Coast data center and let them replicate from the West Coast
    • Found ways to restore directly from the West Coast to get around the throughput limits of downloading from off-site storage
    • Moved all database primaries back to the US East Coast data center
    • Spread read traffic over additional MySQL read replicas in the US East Coast public cloud so replication could catch up
    • Failed over to the original topology once the replicas were in sync
    • Processed the backlog of webhook events and Pages builds, pausing to raise an internal TTL after about 200,000 webhook payloads were dropped
    Action items
    • Reconcile the writes from the captured MySQL binary logs that were not replicated, automatically where possible and with user outreach otherwise
    • Make sure status updates can be published even when GitHub Pages builds are paused
    • Give more accurate public estimates of the time to repair
    • Configure Orchestrator so it cannot promote database primaries across regional boundaries
    • Move to a status reporting mechanism that shows the status of each component of the platform
    • Serve GitHub traffic from multiple data centers in an active/active/active design with N+1 redundancy at the facility level
    • Test assumptions about the system more proactively
    • Validate failure scenarios systematically, with investment in fault injection and chaos engineering tooling
    Lessons

    Orchestrator did what it was configured to do, but the application tier could not work with primaries on the other side of the country: leader election within one region is generally safe, while the sudden cross-country latency was a major contributing factor. The behaviour emerged from a partition larger than any GitHub had seen. Replication caught up along a power decay curve, not a straight line, so the linear estimates of recovery time were wrong. GitHub concluded that tighter operational controls and faster response are not enough on their own and that failure scenarios have to be validated before they happen.

Check your cluster for this

These 8 cases involve Database replication and Database. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Capacity exhaustion1 case

Organisation
  1. IL-0379 InfluxDB Cloud queries in Azure West Europe slowed and timed out as storage pods fell behind and kept restarting

Software defect2 cases

Organisation
  1. IL-0376 A maintenance update set off needless full syncs between Upstash Redis replicas in eu-west-1, slowing the databases
  2. IL-0303 GitHub's MySQL master failed over to a node with a cold buffer pool during a schema migration and GitHub.com went down
    GitHub2012

Breaking change in an upgrade1 case

Organisation
  1. IL-0308 Most RevenueCat backend systems failed after cutover to a new Aurora PostgreSQL 14 cluster as queries became very slow

DNS or network fault2 cases

Organisation
  1. IL-0240 Cloudflare API requests failed and the dashboard slowed for hours after the authentication database lost its replicas
  2. IL-0210 GitHub's MySQL clusters failed over to the US West Coast and the site served slow, stale, inconsistent data for 24 hours
    GitHub2018

Configuration change1 case

Organisation
  1. IL-0430 Mackerel's Redis stopped answering during a replication setup, keepalived failed over by mistake, and Mackerel degraded
    Hatena2018

Operator error1 case

Organisation
  1. IL-0431 During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of data
    Hatena2017