  1. Symptoms

    At 13:02 UTC on 2024-01-23 DigitalOcean posted that, as of 12:18 UTC, its engineers were investigating an issue with Kubernetes clusters in the FRA1 region and that users might see errors when communicating with their clusters. The control planes of the affected DOKS (DigitalOcean Kubernetes) clusters had become inaccessible.

    Trigger

    An incorrect configuration was applied to an internal infrastructure cluster in FRA1 at 12:21 UTC during a maintenance operation.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were investigating errors with Kubernetes clusters in FRA1 as of 12:18 UTC and identified the incorrect configuration as the cause at 12:36.

    Remediation
    • restored each affected cluster's etcd from its latest twice-daily backup
    • restored the stateless control plane components after etcd
    • patched the recovery mechanism after unexpected problems during recovery
    • found and fixed an additional small bug during recovery
    • contacted affected customers directly with further instructions, since some might need to reconfigure Kubernetes resources
    Action items
    • Prevent automatic deletion of infrastructure cluster resources under any circumstances in the production environment
    Lessons

    When managed control planes run as resources in another cluster, one configuration mistake in that cluster can delete hundreds of control planes at once through ordinary automation. The etcd backups limited the damage, but their twice-daily schedule set the worst case at 12 hours of lost control plane state, and the recovery tooling itself needed patching during the incident.

  2. Symptoms

    About a minute after the etcd leader changed, two replicas of the Cortex distributor started logging "context deadline exceeded" when they tried to read keys from etcd. Writes from some customers that landed on those two replicas failed, while the other distributor replicas kept working, so the service saw an error rate of about 20% on writes to the London region of Hosted Prometheus.

    Trigger

    A scheduled Kubernetes version upgrade abruptly terminated the node that ran the etcd leader at 11:19:00 UTC.

    Root cause
    Component
    Contributing factor
    Detection

    An SLO-based alert paged the on-call engineer at 11:31, 11 minutes after the errors started. At a 20% error rate the monthly SLA would have taken about 18 hours to breach.

    Remediation
    • Restarted the two affected Cortex distributor replicas at 11:32, which stopped the errors
    Action items
    • Enable gRPC keepalive probes in the Cortex etcd client (DialKeepAliveTime 10s, DialKeepAliveTimeout, PermitWithoutStream)
    • Make the Kubernetes upgrade process terminate pods and machines gracefully, including the etcd pods managed by the etcd operator
    Lessons

    When a node dies abruptly, clients holding TCP connections to it are not told; without keepalive probes an etcd client can keep sending requests into a dead connection long after a new leader exists. A failover that works on the server side still needs clients that detect the dead peer. Node replacement during cluster upgrades should drain pods gracefully, including pods owned by operators that the upgrade scripts do not know about, and should give instances enough time to shut down.

Check your cluster for this