Graph
Cases2 cases
1 to 2 of 2
IL-0096A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)2i2c2022- Symptoms
A user of the LIS JupyterHub reported a "backoff after failed scale-up" error, and user servers would not start. An engineer opened incident #36, "LIS hub cannot scale", at 5:40 AM Pacific on 14 November 2022.
- Trigger
At 10 AM UK time on 14 November 2022, the B zone of Google Cloud's europe-west2 region (London) ran out of resources to allocate. The LIS cluster's nodes were restricted to that zone.
- Root cause
- Component
- Contributing factor
- Detection
A user reported the "backoff after failed scale-up" error; an engineer opened the incident at 5:40 AM Pacific, about three hours and forty minutes after the zone ran out of resources.
- Remediation
- edited the node pool in the GCP console to allow node creation in the A and C zones of europe-west2, which were not exhausted
- Action items
- Either restrict the node pool back to the B zone after the Black Friday event, or move the cluster and the NFS Filestore to the A zone (infrastructure issue #1944)
- Investigate an enterprise plan that allows a regional NFS, at higher cost (infrastructure issue #1945)
- Make sure PagerDuty notifications always get through to engineers (team-compass issue #574)
- Lessons
A node pool pinned to one zone for storage performance cannot scale when the cloud provider runs out of capacity in that zone. The autoscaler's "backoff after failed scale-up" message usually points to quotas, and raising quotas does nothing here; the ZONE_RESOURCE_POOL_EXHAUSTED error in the logs is what identifies a zone without capacity. The review found that one engineer wearing many hats (incident commander, comms and debugging), with pages not reaching the other responders, made the response harder; a team response would have given more support.
IL-0014A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPAloveholidays2019- Symptoms
On the evening of a long-overdue upgrade of a loveholidays production GKE cluster from 1.10.X to 1.12.5-gke.10, planned to take 2 to 2.5 hours, the master upgrade and the first two 7-node NodePools went smoothly. After that the NodePool upgrades slowed to a crawl. Each node is cordoned, drained and upgraded in turn. Even a 14-node cluster at about 5 minutes per node took over an hour, and with about 100 more nodes to go, some of them taking over 15 minutes to drain, the sequential drains were too slow to finish at a reasonable hour.
- Trigger
A manual upgrade of the GKE masters and NodePools from 1.10.X to 1.12.5-gke.10, two versions at once, on 19 March 2019; GKE's release notes of 14 March had already said that version was no longer available for new clusters or master upgrades because masters showed elevated error rates, but it could still be selected.
- Root cause
- Component
- Contributing factor
- Detection
The slow drains, zombie nodes and stuck NodePool were seen by the engineer running the upgrade; the broken Ingress was noticed after the upgrade and explained by Google support; the HPA problem was noticed the next day.
- Remediation
- drained the remaining NodePool nodes ahead of the upgrade with kubectl drain --ignore-daemonsets --delete-local-data
- deleted the zombie instances from the managed instance group with gcloud compute instance-groups managed delete-instances
- cancelled the stuck UPGRADE_NODES operation with gcloud beta container operations cancel
- used kubectl port-forward in place of the broken internal Ingresses
- scaled down the older of two active ReplicaSets, or triggered a dummy deployment, to bring the HPA back
- Action items
- Alert when a HorizontalPodAutoscaler is at 70% and at 100% of its capacity
- Alert when a deployment has had two active ReplicaSets for 30 minutes and for 60 minutes
- Re-evaluate termination grace periods that were set to arbitrary large values
- Read the GKE release notes before every cluster upgrade
- Use auto-upgrade in non-production environments, and manual cluster upgrades with automatic node upgrades in production
- Keep environments as identical as possible, including resource names
- Lessons
Read the release notes before upgrading: the target version had been withdrawn five days earlier. Drain time depends on pod configuration, so emptyDir volumes, long grace periods and missing disruption budgets turn a NodePool upgrade into hours. Pre-production only catches problems like the ingress bug if it matches production down to resource names. Auto-upgrades in non-production surface problems early, and a mix of manual cluster upgrades and automatic node upgrades in production keeps clusters current without much effort.
These 2 cases involve Cluster autoscaler and Node pool. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Cloud provider outage2 cases
- Component
- Contributing factor
- Organisation
IL-0096A GKE node pool pinned to the europe-west2-b zone could not scale for 6.5 hours because Google ran out of resources in that zone (ZONE_RESOURCE_POOL_EXHAUSTED)2i2c2022IL-0014A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPAloveholidays2019