Incident Library
Applied filters ComponentNode poolSymptomNode NotReadyClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases3 cases

1 to 3 of 3

  1. Symptoms

    From 20:31 UTC on July 9, 2026, DigitalOcean reported a problem with Kubernetes deployments in its NYC1 region. Application workloads could see intermittent DNS failures and NodeNotReady events.

    Root cause
    Component
    Contributing factor
    Lessons

    Cluster DNS is sensitive to latency, and CoreDNS on shared-CPU nodes can time out intermittently. DigitalOcean's advice is to place CoreDNS on dedicated-CPU node pools and to run enough CoreDNS replicas.

  2. Symptoms

    From 08:00 US/Pacific on 12 March 2024, GKE GPU nodes running Container-Optimized OS (COS) that were newly created or recreated came up with GPU drivers that did not work, so workloads that used the GPUs could not run. GKE showed elevated errors.

    Root cause
    Component
    Contributing factor
    Detection

    The report does not say how Google detected the issue. Affected users saw "Failed to download GPU driver installer, status: 403 Forbidden" on the GPU node when installing the driver.

    Remediation
    • Halted automatic node recreations, which attempt GPU driver downloads, until the issue was mitigated
    • Worked with the driver partner to resolve access to the driver download bucket
    Lessons

    The status page report states no lessons or follow-up actions.

  3. Symptoms

    At 14:05 on 25 July 2023, a high-priority PagerDuty alert from Pingdom reported that the "Prometheus - live healthcheck" was DOWN. Prometheus on the live cluster was unavailable, and the Cloud Platform lost its monitoring for a while.

    Trigger

    The growing number of namespaces and Prometheus rules raised Prometheus' memory needs beyond what its node instance size could hold.

    Root cause
    Component
    Contributing factor
    Detection

    A Pingdom health check on Prometheus failed and raised a high-priority PagerDuty alert.

    Remediation
    • drained the monitoring node, moving Prometheus to another monitoring node
    • changed the node instance size to r6i.4xlarge
    • raised the Prometheus memory limit to 100Gi
    • set the Prometheus container limits to 12 CPU cores and 110Gi of memory
    Action items
    • Add an alert on node memory usage and on a pod using up most of a node's memory (issue #4538)
Check your cluster for this

These 3 cases involve Node pool and CoreDNS. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.