Incident Library
Applied filters ComponentPCIe linkClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases2 cases

1 to 2 of 2

  1. Symptoms

    A distributed training task on 128 machines in ByteDance's production environment slowed down severely for 40 minutes but kept running, holding thousands of V100 GPUs at reduced speed. The alerting in place notified engineers only when a task stopped completely, so the slowdown itself raised no alert.

    Trigger

    The PCIe link of one machine degraded from 6.4Gbps to 4Gbps during the training task.

    Root cause
    Component
    Contributing factor
    Detection

    No alert fired because alerts came only when a task stopped. Engineers from several teams found the faulty machine by manual diagnosis, which took 40 minutes.

    Action items
    • Detect faulty machines automatically during training by comparing each machine's per-second monitoring metrics with the other machines (Minder)
    Lessons

    Some faults slow a task without stopping it, and alerting that waits for a halted task misses them. Logs alone are incomplete because they do not contain monitoring metrics such as PFC packet rates, and no single metric reveals every fault type, so ByteDance compares machines with each other on several metrics and treats a difference that lasts for minutes as a fault.

  2. Symptoms

    On IBM's Vela AI cluster, GPU nodes with PCI-E Gen3 and Gen4 links sometimes performed like a much older PCI-E generation, for example at 4 GB/s, which resembles PCI-E Gen 1. Training jobs on those nodes slowed by anywhere from a few percent to 2x, and PCI-E link downgrades were the most frequently observed failure on Vela.

    Root cause
    Component
    Contributing factor
    –
    Detection

    Autopilot measures PCI-E bandwidth between host and device on every node with periodic lightweight tests, and an alert fires when the average of 12 hourly samples falls below a threshold for the PCI-E generation; affected nodes are listed on a Grafana dashboard.

    Remediation
    • Reset the PCI-E device, usually by rebooting the VM, which resolved the downgrade at least 95% of the time
    • Rebooted VMs periodically
    Action items
    • Run periodic lightweight PCI-E link tests through Autopilot on every node and alert when the 12-hour average falls below a threshold
    • Keep investigating the root cause of the PCI-E link degradations
    Lessons

    In distributed training, a drop in the performance of a single node reduces the performance of the whole job until the slow node is identified and removed or fixed. Lightweight periodic tests averaged over a long window can find degraded PCI-E links accurately while customer jobs keep running, which lets site reliability engineers act before users report a problem.

Check your cluster for this

These 2 cases involve PCIe link and InfiniBand fabric. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.