Incident Library
Applied filters ComponentProgressive delivery controllerFactorAutomation amplificationOrganisationGunosyClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases1 case

1 to 1 of 1

  1. Symptoms

    During a traffic surge from a breaking news alert, pods of a Gunosy service on Kubernetes could not start because the containers could not read their settings from the ConfigMap. The pods that kept running took the extra load and were restarted, failed to start again, and pod after pod died.

    Trigger

    A breaking news alert increased traffic and pods were scaled out automatically while a release that removed an old database's settings from the ConfigMap had been rolled out to only one canary pod.

    Root cause
    Component
    Contributing factor
    Action items
    • Configure Argo Rollouts to roll out automatically, with setWeight 1, a one-hour pause and then setWeight 100
    • Add the "helm.sh/resource-policy": keep annotation so Helm keeps past versions of the ConfigMap
    • Build and use a Helm plugin, helm-clear, that keeps only the last few ConfigMap versions by the revision number in their names, set to keep 5 in CD
    Lessons

    Gunosy holds that a review that only resolves to be careful next time would soon be followed by the same failure, because human attention cannot be relied on, so each incident gets a permanent fix built into the system. Keeping past ConfigMap versions also made it possible to roll back quickly without going through CI/CD, which a ConfigMap change had previously prevented.

Check your cluster for this

This case involves ConfigMaps and Secrets and Helm. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1