  1. Symptoms

    At 12:32 Prometheus on the Cloud Platform was not available after a planned change, and the Prometheus pod had restarted several times. The platform lost its monitoring and had missing metrics for the period.

    Trigger

    A planned change restarted Prometheus at a time when the WAL count was high.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw that the Prometheus pod had restarted several times after the planned change.

    Remediation
    • raised the Prometheus startupProbe threshold to 30 minutes
    Action items
    • Perform planned Prometheus restarts when the WAL count is lower
    • Set the default CPU and memory requests to meet maximum usage
    • Create a test setup that recreates the live WAL count
    • Explore the memory-snapshot-on-shutdown and auto-gomaxprocs feature flags
    • Explore storing WAL files remotely in a different location
    • Look into a blue-green Prometheus to test changes on a live-like setup before applying them to live
    • Spike into Amazon Managed Prometheus
  2. Symptoms

    At 10:15 on 1 November 2023 a Pingdom check raised a PagerDuty high-priority alert that the "Prometheus - live healthcheck is DOWN". The same alert fired for the third time within a few minutes, and the incident was declared at 10:41.

    Root cause
    Component
    Contributing factor
    –
    Detection

    A Pingdom health check on the live Prometheus failed and raised a PagerDuty high-priority alert.

    Remediation
    • increased the Prometheus readiness probe timeout from 3 to 6 seconds
    Action items
    • Inspect more closely to identify this kind of failure earlier
    • Investigate whether the ingestion of data into the database is too big or too long
    • Check whether executing some queries makes Prometheus work harder and stop responding to the readiness probe
    • Check whether any other service probing Prometheus triggers the restart
    • Check whether regular Velero backups disturb EBS reads and writes and cause the restart
Check your cluster for this