  1. Symptoms

    At 09:33 UTC on 14 February 2023 end users told the platform team that Kubernetes logs were not arriving in CloudWatch as expected. The investigation went through fluentd and found that the nodes were running containerd as their container runtime instead of docker-shim. A scheduled node rollover the day before, at 07:30 UTC on 13 February, had set containerd as the default runtime by accident.

    Trigger

    A scheduled node rollover had accidentally made containerd the default container runtime, which stopped log shipping to CloudWatch; the unscheduled rollover to revert it timed out, and the pipeline run that followed reduced the Auto Scaling group from 30 to 15 instances.

    Root cause
    Component
    Contributing factor
    Detection

    End users reported the missing CloudWatch logs that started the work. The postmortem lists 2 minutes as the time to detection of the node failure.

    Remediation
    • ran the node rollover script to add new nodes, which failed on a timeout from Docker Hub
    • ran the node rollover script a second time, which added new nodes that the load balancer marked healthy at 11:01 UTC
    Action items
    • Document the rollover process, especially what can be done when it goes wrong
    • Investigate options for improving the rollover process
    • Add fluentd log collection to the QA test suite so logs are covered end to end
    • Add alarms for fluentd when too little or no log data is sent
    • Implement a staging environment
    • Implement guards against selecting an invalid container runtime
    Lessons

    When a change goes wrong, rolling back to a known working configuration is safer than rushing a fix, which can make the damage worse. Launching new worker nodes depends on the cloud-init script not failing in any way. The QA configuration differed from production, there was no staging environment, the QA tests did not cover fluentd log collection, and the rollover process had no documentation for when it fails.

  2. Symptoms

    On 2022-10-31 a planned upgrade of the vpc-cni EKS add-on, started from the deployment pipeline at 13:45 UTC, timed out at 14:10. Only about 10 of the 45 aws-node pods had upgraded, 5 were stuck in Terminating and the other 30 had not been attempted.

    Trigger

    At 07:30 UTC on 2022-10-31 the daily node rollover replaced the existing nodes with nodes built from AMI v20221027, the latest AWS EKS node AMI, released on 2022-10-29 and later recalled because of a kernel issue.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed nodes flapping between NodeNotReady and NodeReady ("KubeletNotReady PLEG is not healthy") at 14:30 UTC while watching the stalled vpc-cni upgrade, about seven hours after the rollover. Time to detection was 7 hours. Alerting did not catch the NodeNotReady events or the socket growth.

    Remediation
    • cordoned, drained and deleted 15 stuck nodes one at a time to complete the vpc-cni upgrade
    • changed the Terraform infrastructure-modules so a specific AMI could be set
    • rolled the EC2 Auto Scaling group launch configuration back to the previous known good AMI through the pipeline
    Action items
    • Reach out to teams with suggestions about readiness and liveness probes
    • Create a dashboard for readiness and liveness probe coverage
    • Write a wiki article on readiness and liveness probes and their usefulness
    • Modify infrastructure-modules to allow specifying a particular AMI
    • Schedule a discussion on whether to take the latest AMI immediately and how to test new AMIs before they are deployed
    • Implement alerting on abnormal NodeNotReady events and on increased socket use
    • Create a learning path for Kubernetes within the team
    • Collect logs from nodes centrally
    • Create a Prometheus exporter that retrieves the latest available AMI, with a dashboard and alerts
    Lessons

    When a new node AMI has just been rolled out, upgrading other cluster components on the same day makes it hard to tell which change is causing trouble; here the vpc-cni upgrade on the same day confused matters. Taking the latest AMI automatically with no way to pin one meant a rollback first needed a Terraform change. The team also concluded that it needs better communication paths with application teams during incidents.

Check your cluster for this

These 2 cases involve Node launch template and Terraform. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.