Incident Library
Applied filters SymptomHigh latencyFactorMonitoring blind spotDomainKubernetesClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases9 cases

1 to 5 of 9

  1. Symptoms

    An e-commerce platform suddenly became slow to respond, worst on the product lookup page, and users began reporting that the page would not open.

    Trigger

    A post on the external community Ppomppu linked to the platform and brought a large number of users in a short time, who called the product lookup API heavily.

    Root cause
    Component
    Contributing factor
    Detection

    Users reported that the product page would not open. The dashboard showed all pods Running, and the namespace CPU usage near 100% and the CPU usage metrics pointed to throttling.

    Remediation
    • raised the HPA minReplicas from 5 to 10
    • raised the container CPU limit from 1 core to 2 cores
    Action items
    • Keep adjusting the CPU limit to a suitable level through monitoring
    Lessons

    CPU throttling is hard to notice: pods stay Running, nothing restarts and the logs show no clear error, so a pod list does not reveal it and CPU usage metrics do. Settings that had handled expected event traffic became the bottleneck as soon as one external post multiplied the traffic. The author concludes that the team needs more preparation for traffic pattern changes and more thought about resource settings.

  2. Symptoms

    Shortly after 29CM's Igu Week sale began on 3 November 2025, the servers for the display domain, which serve search results and product listings, showed anomalies. Some pods went down and stopped taking traffic, and the remaining pods received more traffic than they could handle and saturated their Netty event loops.

    Trigger

    Igu Week, 29CM's largest Black Friday sale and its busiest traffic of the year, raised Redis network traffic to about four times normal.

    Root cause
    Component
    Contributing factor
    Detection

    Anomalies on the display servers, pods going down and Netty event loops saturating, were the first sign. The Redis cause was found from Redis health check failure logs and then the Redis network metrics.

    Remediation
    • Scaled the Redis nodes up from cache.r7g.large to cache.r7g.2xlarge, about twice the baseline network bandwidth
    Action items
    • Extended the monitoring dashboard to show in real time whether network in and out bandwidth exceeds the baseline, with metrics such as aws.elasticache.network_bandwidth_out_allowance_exceeded and aws.elasticache.traffic_management_active
    • Added Datadog alerts that fire when network bandwidth crosses a threshold
    • Added a Caffeine local cache in front of Redis for data that changes rarely
    • Look into compressing cached data with Snappy to reduce Redis network bandwidth
    • Look into storing cached data as Protocol Buffers instead of JSON; measured on the cached Item Document data, Snappy and protobuf together are expected to cut the size by about 73%
    • Keep improving the architecture for traffic growth, building on the cache restructuring, stronger monitoring and read separation already applied
    Lessons

    CPU and memory metrics alone did not show the problem, so Redis needs network monitoring against the node's bandwidth baseline. Burst credits kept the nodes working for about two hours after traffic passed the baseline, which delayed the failure and made its cause slower to find.

  3. Symptoms

    In Microsoft's cloud LLM inference service, the inference engines themselves failed in 94 of the 156 high-severity incidents from April to June 2025 (≈60%). Requests timed out or ran into resource exhaustion under load, and callers got HTTP 408, 429 and 5xx errors.

    Trigger

    Bursty load, traffic with unusually high sampling parameters and long-running requests pushed the inference engines into resource exhaustion and timeouts.

    Root cause
    Component
    Contributing factor
    Detection

    Across the 156 incidents, 115 (≈74%) were auto-detected, meaning health probes or DRI pipelines alerted before customers reported the problem; the others were not.

    Remediation
    • Enabled dynamic pushback at the load balancer with caps on pending tokens and requests
    • Tuned request batching and GPU/CPU replica counts
    • Improved gRPC backoff and error mapping
    • Limited sampling parameters and throttled per client
    • Enabled streaming, tuned request batching and capped pending tokens against engine connection timeouts on long-running requests
    • Increased capacity, routed traffic to healthy endpoints and restarted nodes, the actions applied mostly to inference engine failures
    Action items
    • Optimise serving for long-running requests and high sampling regimes, with connection liveness and GPU capacity-aware routing as the main levers
    • Expand health-probe-driven failover and GPU capacity-aware routing so traffic moves off degraded endpoints on its own
    • Forecast token and throughput growth and automate capacity increase decisions
    • Deploy adaptive alerting and expand engine-level telemetry to close detection gaps
    Lessons

    Hotfixes restore correctness but lengthen time to mitigate, while traffic routing and node rebalancing mitigate faster under overload and timeout patterns. Even with AIOps tooling a meaningful share of incidents still needs manual detection or judgement, so health-probe-driven traffic routing, restarts and capacity increases are the decisions to automate first.

  4. Symptoms

    Request latency from the Temporal Server History service, the service that starts workflow executions and records their progress, was higher and less steady than it should be on a self-hosted Kubernetes deployment. The CPU dashboard showed the history pods using less than 60 percent of their CPU, yet the same pods were being throttled.

    Trigger

    Normal load on History pods that had a CPU limit of 2 cores on 8-core nodes, with the Go runtime's GOMAXPROCS left at its default of one per node core.

    Root cause
    Component
    Contributing factor
    Detection

    A Prometheus query for CPU throttling showed the history pods throttled although their CPU usage read under 60 percent.

    Remediation
    • set the GOMAXPROCS environment variable to 2 to match the 2-core CPU limit
    Action items
    • Set GOMAXPROCS automatically from the Kubernetes CPU limit, from Temporal release 1.21.0
    Lessons

    A CPU usage graph averaged over 15 seconds or more can sit far below 100 percent while a container is being throttled, so throttling needs its own metric. A Go program in a container should have GOMAXPROCS matched to its CPU limit, or to its CPU request when it has no limit. The author recommends not using CPU limits at all.

  5. Symptoms

    From September 2021, each rollout of an update to Datadog's metrics query service, which serves real-time and historical metric data to the web frontend and to monitor evaluation, came with a rise in errors. Clients retried failed queries, so few errors reached users, but the retries slowed dashboards and monitors. The service's logs showed DNS errors stopping it from connecting to the data stores it depends on.

    Trigger

    Rollouts of the metrics query service, which delete the old pods. The client behaviour behind the failures came from an August 2021 rollout of the metrics query clients that applied round_robin as the new default gRPC load balancing policy.

    Root cause
    Component
    Contributing factor
    Detection

    Errors rose during rollouts of the metrics query service, and the service's logs showed DNS errors when connecting to its data stores.

    Remediation
    • Raised the memory of the node-local-dns pods from 64 MB to 256 MB, which stopped the OOM kills but not the DNS errors
    • Tested larger instance types and confirmed that scaling up the service's infrastructure resolved the errors
    • Removed the custom gRPC reconnect parameters from the clients to restore the defaults
    Action items
    • Contribute a change to Cilium that adds an unreachable route for a deleted pod's IP so clients get an ICMP error
    Lessons

    The errors looked like DNS but were not. ENA metrics and VPC Flow Logs gave the visibility into VPC connection tracking that host metrics did not, and Cilium, Kubernetes and AWS networking interact in ways that can make reverse path filtering drop packets it should allow. DNS propagation time depends on many settings. The causes were changes Datadog had made itself, to work around a dependency bug, to resolve earlier incidents and to override default reconnect parameters, which looked safe at the time and showed their effects much later, when the link was hard to see.

Check your cluster for this

These 9 cases involve Container CPU limit and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause4

Capacity exhaustion5 cases

  1. IL-0181 A traffic spike from an external community post pushed product API pods into CPU throttling under a 1-core limit, and an e-commerce product page slowed down while every pod stayed Running
    Kevin2026
  2. IL-0581 29CM product display servers lost pods and saturated Netty event loops on the first day of the Igu Week sale
  3. IL-0413 LLM inference engines timed out or ran out of resources under load in about 60% of 156 severe incidents at Microsoft
  4. IL-0028 Temporal History service latency rose because its pods were CPU-throttled while CPU usage read below 60 percent
  5. IL-0075 Kubernetes API servers pegged on CPU when the cluster grew to about 290 nodes, traced to Datadog agents polling the API

Configuration change2 cases

Organisation
  1. IL-0461 Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNS
  2. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Cloud provider outage1 case

Organisation
  1. IL-0205 The GKE cluster autoscaler could not add nodes to GitLab.com's production cluster because Google Cloud ran out of SSD persistent disks in us-east1
    GitLab2021

Software defect1 case

Organisation
  1. IL-0012 CPU limits and an unpatched kernel CFS quota bug throttled multi-threaded services into stalls, failed health checks and timeouts
    Omio2020