Incident Library
Applied filters Root causeCapacity exhaustionSymptomProbe failuresDomainKubernetesClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases6 cases

1 to 5 of 6

  1. Symptoms

    Shortly after 29CM's Igu Week sale began on 3 November 2025, the servers for the display domain, which serve search results and product listings, showed anomalies. Some pods went down and stopped taking traffic, and the remaining pods received more traffic than they could handle and saturated their Netty event loops.

    Trigger

    Igu Week, 29CM's largest Black Friday sale and its busiest traffic of the year, raised Redis network traffic to about four times normal.

    Root cause
    Component
    Contributing factor
    Detection

    Anomalies on the display servers, pods going down and Netty event loops saturating, were the first sign. The Redis cause was found from Redis health check failure logs and then the Redis network metrics.

    Remediation
    • Scaled the Redis nodes up from cache.r7g.large to cache.r7g.2xlarge, about twice the baseline network bandwidth
    Action items
    • Extended the monitoring dashboard to show in real time whether network in and out bandwidth exceeds the baseline, with metrics such as aws.elasticache.network_bandwidth_out_allowance_exceeded and aws.elasticache.traffic_management_active
    • Added Datadog alerts that fire when network bandwidth crosses a threshold
    • Added a Caffeine local cache in front of Redis for data that changes rarely
    • Look into compressing cached data with Snappy to reduce Redis network bandwidth
    • Look into storing cached data as Protocol Buffers instead of JSON; measured on the cached Item Document data, Snappy and protobuf together are expected to cut the size by about 73%
    • Keep improving the architecture for traffic growth, building on the cache restructuring, stronger monitoring and read separation already applied
    Lessons

    CPU and memory metrics alone did not show the problem, so Redis needs network monitoring against the node's bandwidth baseline. Burst credits kept the nodes working for about two hours after traffic passed the baseline, which delayed the failure and made its cause slower to find.

  2. Symptoms

    At 05:01 UTC on 9 October 2024 a page fired for GatewayBackendErrorsHigh, elevated 5xx errors from page-analytics_cluster in codfw, followed by a growing number of KubernetesCalicoDown alerts for WikiKube nodes not running the calico-node pod and by MediaWikiMemcachedHighErrorRate. For about an hour uncached MediaWiki requests, such as those of logged-in users, edits and API calls, saw high latency or errors.

    Trigger

    An operator used the new mwscript-k8s utility to run a batch of video transcode maintenance, the TimedMediaHandler requeueTranscodes.php script. mwscript-k8s deploys a whole helm release for every script invocation, so the batch created close to 2k Calico NetworkPolicies along with many other resources over several hours.

    Root cause
    Component
    Contributing factor
    Detection

    Automated monitoring detected the issue and paged the on-call SRE: GatewayBackendErrorsHigh at 05:01:36 UTC, 16 KubernetesCalicoDown alerts at 05:03:32 UTC and MediaWikiMemcachedHighErrorRate at 05:04:15 UTC.

    Remediation
    • Raised the resource limits of the Calico and Typha pods and applied the change with helmfile, which redeployed all Calico pods
    Action items
    • Stop mwscript-k8s from creating so many resources
    Lessons

    The incident came close to a full outage. Automated monitoring caught it and many responders found the cause, but end users were affected and responders were unsure whether they could switch over to eqiad. The problem was noticed just before the hand-off from Americas to EMEA SRE shifts, a period with a long-known lack of coverage, and it helped that the transcodes were not queued on a Friday evening in the US.

  3. Symptoms

    After an upgrade of the kube-prometheus-stack Helm chart, several pods stayed not ready. Among them was prometheus-prometheus-operator-prometheus-0, showing 3/4 Running and a recent termination.

    Trigger

    During the kube-prometheus-stack Helm chart upgrade, Prometheus had to replay its write-ahead log on startup, and the replay needed more memory than its limit allowed.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed pods not ready after the Helm chart upgrade and found the OOMKilled termination with kubectl describe pod.

    Remediation
    • ran promtool tsdb analyze inside the Prometheus pod to find high-cardinality metrics such as haproxy_server_http_responses_total
    Action items
    • Verify that the memory overhead during WAL replay stays within acceptable limits, for example 10 to 15%, and do not run Prometheus close to its memory limit
    • Optimise storage, scraping and remote write configuration and upgrade to newer Prometheus releases
    • Recover automatically from OOM crash loops, for example by deleting the WAL on OOM events
    • Enforce scrape limits so Prometheus stops scraping targets when memory use passes a threshold
    Lessons

    Size Prometheus for its restart, not only for steady state: WAL replay can need far more memory than normal running, and a Prometheus that already runs near its limit can be OOM-killed during the replay. Much of Prometheus memory use comes from cardinality, which promtool tsdb analyze can measure even when Prometheus itself is down.

  4. Symptoms

    At 12:32 Prometheus on the Cloud Platform was not available after a planned change, and the Prometheus pod had restarted several times. The platform lost its monitoring and had missing metrics for the period.

    Trigger

    A planned change restarted Prometheus at a time when the WAL count was high.

    Root cause
    Component
    Contributing factor
    Detection

    The team saw that the Prometheus pod had restarted several times after the planned change.

    Remediation
    • raised the Prometheus startupProbe threshold to 30 minutes
    Action items
    • Perform planned Prometheus restarts when the WAL count is lower
    • Set the default CPU and memory requests to meet maximum usage
    • Create a test setup that recreates the live WAL count
    • Explore the memory-snapshot-on-shutdown and auto-gomaxprocs feature flags
    • Explore storing WAL files remotely in a different location
    • Look into a blue-green Prometheus to test changes on a live-like setup before applying them to live
    • Spike into Amazon Managed Prometheus
  5. Symptoms

    One Monday morning the author opened the Prometheus dashboard to check a Kubernetes cluster for alerts and could not reach it. The Prometheus pod was in CrashLoopBackOff: kubectl get pods showed it 1/2 ready with 950 restarts over 3d20h on worker3.

    Trigger

    After start, the Prometheus time series count rose to 2,162,256 within five minutes and its memory use filled the 8GB host.

    Root cause
    Component
    Contributing factor
    Detection

    The author found it on a Monday morning when the Prometheus dashboard, opened to check the cluster for alerts, could not be reached.

    Remediation
    • removed most of the unnecessary settings from the Prometheus ConfigMap, after which the container stopped crashing
    Action items
    • Set appropriate resource requests and limits on the Prometheus pod
    • Reduce unneeded metrics by adjusting scrape targets or scrape interval
    • Estimate Prometheus memory needs, provide dedicated hosts with a node label such as deploy-topology: Prometheus, and pin the Prometheus pod to them with a nodeSelector
    Lessons

    Exit code 137 together with an OOM event in the kubelet log means the kernel killed the container, not kubelet. Under node memory pressure the kernel kills the process with the highest score, and kubelet derives each container's oom_score_adj from the pod's QoS class: a container without a memory request in a pod where another container has one ends up Burstable with a score near 1000, so it is killed first. In a large cluster, Prometheus memory needs to be estimated from the expected series count and requested explicitly.

Check your cluster for this

These 6 cases involve Prometheus and Container memory limit. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1