  1. Symptoms

    From 20:31 UTC on July 9, 2026, DigitalOcean reported a problem with Kubernetes deployments in its NYC1 region. Application workloads could see intermittent DNS failures and NodeNotReady events.

    Root cause
    Component
    Contributing factor
    Lessons

    Cluster DNS is sensitive to latency, and CoreDNS on shared-CPU nodes can time out intermittently. DigitalOcean's advice is to place CoreDNS on dedicated-CPU node pools and to run enough CoreDNS replicas.

  2. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

  3. Symptoms

    On 18 October 2024, from 7:50 to 8:01 UTC, about 25% of the hypervisors in Scaleway's FR-PAR-1 availability zone lost VPC connectivity with the rest of the region, and products that use VPC failed with them. Public internet connectivity and Elastic Metal VPC connectivity were not affected.

    Trigger

    At 6:20 UTC a Top of Rack switch in FR-PAR-1 had a software crash. One of the two BGP route reflectors for VPC ran on a hypervisor in that rack and was left in an abnormal state.

    Root cause
    Component
    Contributing factor
    Detection

    Health-check monitoring on both route reflectors detected the anomaly, and the Scaleway Customer Excellence and SRE teams detected the customer impact and opened an incident.

    Remediation
    • Fixed both VPC route reflectors by manual action
    Action items
    • Fixed the autohealing mechanism that had failed to fix route reflectors stuck in a stale state; the fix is https://github.com/FRRouting/frr/pull/17163
    • Run different software versions on the route reflectors so a single bug cannot stop several instances
    • Investigate the software issue that left the route reflectors in a stale state
  4. Symptoms

    From 22:25 to 22:50 UTC every DigitalOcean service in the SFO3 region had network connectivity problems, as traffic between the datacenter and the backbone dropped. Traffic through the router was back by 22:30 and SFO3's control plane systems had reconnected by 22:50, and most services recovered then.

    Trigger

    Most of the line cards on one SFO3 core router rebooted at the same time at 22:21 UTC because of hardware errors on the device.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • The crashed line cards came back online and traffic on the core router was restored
    • Manually recycled all affected nodes across the SFO3 DOKS fleet
    Action items
    • Work with the router vendor's support team to find the root cause of the line card crash
    • Upgrade software on the core routers in SFO3
    • Raise thresholds for automated remediation so affected nodes are restored without manual action
    Lessons

    A short network fault can leave Kubernetes nodes broken long after the network itself is healthy, when the guest networking on the machines does not recover by itself. Checking node health and the API servers after the network returns, and having automated remediation that is allowed to replace many nodes at once, shortens that tail.

  5. Symptoms

    At 10:01 UTC on 2024-03-13 a Kubernetes node entered NotReady state, with CPU requests at 78% and memory requests at 82%. An alert fired in Slack at 10:03 and was picked up at 10:05. An attempt to SSH into the node at 10:13 failed because it was unresponsive; it started responding again at 10:19.

    Trigger

    Pods of a dev container that used Hangfire to trigger jobs failed with OOM and crash-looped on a node where a Grafana Agent pod was already using a lot of memory.

    Root cause
    Component
    Contributing factor
    Detection

    A Slack alert fired two minutes after the node went NotReady and was picked up two minutes later; the second node's NotReady at 15:03 also raised a Slack alert.

    Remediation
    • marked the EC2 instance unhealthy so a new node started
    • cordoned and force-drained the NotReady node and terminated its EC2 instance
    • removed the new LimitRange from the Grafana Agent namespace and restarted the Grafana Agent pod
    • scaled the dev container to 0 replicas, after which EC2 network traffic returned to normal
    • after the second NotReady, scaled the dev container to 0 replicas again and added a new node
    • emailed the team that owns the dev container, which confirmed it was working on a fix
    Action items
    • Move grafana-agent to the monitoring node group
    • Add alerts for when bandwidth across the cluster reaches a certain threshold
    • Investigate whether memory limits can be set on the grafana-agent Helm chart
    • Investigate grafana-agent memory usage
    • Ask Grafana support whether grafana-agent should use a PVC
    • Consider pushing node logs to Loki with limited retention
    • Create a wiki page with common metrics and log queries to check when investigating issues with Kubernetes nodes
    Lessons

    Dev workloads mixed with production let one crash-looping dev container take down nodes that production also used, and a monitoring agent outside its dedicated node group added to the memory pressure. Scaling the suspect container back up before its owners had fixed it brought the failure back on the replacement node. The team also noted that action items from earlier post-mortems need follow-up, and that knowledge of useful CloudWatch metrics had not been shared, which made the diagnosis harder.

Check your cluster for this

These 30 cases involve kubelet and Node operating system image. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause10

Capacity exhaustion10 cases

  1. IL-0155 Some DOKS clusters in NYC1 saw intermittent DNS timeouts and NodeNotReady events because CoreDNS ran on shared-CPU Droplet worker nodes
  2. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  3. IL-0110 A Grafana Agent pod's high memory use and crash-looping Hangfire pods drove a Kubernetes node into system OOM and NotReady, twice in one day
    DFDS2024
  4. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  5. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  6. IL-0016 Prometheus on the live cluster ran out of memory and was OOMKilled, and the monitoring node it ran on went NotReady
  7. IL-0401 Prow jobs on the k8s-prow-build GKE cluster failed and merges stalled as nodes hit IOPS throttling and kernel panics
  8. IL-0064 CPU-heavy pods packed onto one Google Cloud node drove it to kernel panics, and the crash moved from node to node until the site was down
  9. IL-0036 A reindex Job that kept failing exhausted one node after another until the whole cluster was down
  10. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Software defect6 cases

  1. IL-0347 About 25% of Scaleway FR-PAR-1 hypervisors lost VPC connectivity when both VPC BGP route reflectors got stuck
  2. IL-0112 The daily node rollover put DFDS's EKS nodes on an AMI later recalled for a kernel issue, causing "PLEG is not healthy" NodeNotReady flaps and pod network timeouts
    DFDS2022
  3. IL-0029 Slow user-facing services from CPU throttling on containers that used far less CPU than their limit
    Buffer2020
  4. IL-0030 Most nodes of a cluster went NotReady together for 15 minutes while the API server sat behind an AWS ELB
  5. IL-0074 All AirMap platform services down as worker nodes went NotReady and pods crash-looped on network and DNS failures
    AirMap2018
  6. IL-0038 kubelet rollout hit a Kubernetes bug and left every node in a cluster NotReady, triggering mass pod eviction
    Oath2018

DNS or network fault1 case

Contributing factor
–
Organisation
  1. IL-0154 Line cards on an SFO3 core router rebooted together and halved backbone capacity, and DOKS nodes whose guest networking did not recover stayed NotReady with degraded API servers until all affected nodes in the SFO3 DOKS fleet were recycled

Dependency failure2 cases

  1. IL-0021 GKE GPU nodes on Container-Optimized OS could not download NVIDIA drivers (403 Forbidden) and came up without working GPUs
  2. IL-0073 Intermittent Kafka connectivity overloaded Docker daemons, set off a node rescheduling cascade and poisoned the Consul gossip mesh
    Target2019

Configuration change3 cases

  1. IL-0153 DOKS worker nodes went NotReady at 06:00 UTC on three days because a systemd timer in the Debian image ran apt upgrade and killed it mid kernel upgrade, breaking node networking
  2. IL-0231 Deleting EKS managed node groups also deleted Karpenter's instance profile, and every Stytch worker node shut down
    Stytch2023
  3. IL-0035 Worker nodes went NotReady after a new ElastAlert rule without memory limits used up node memory
    NU.nl2019

Hardware failure1 case

Contributing factor
Organisation
  1. IL-0185 A disk failure made the first control plane node of a Kubespray cluster read-only, and recovery needed the Kubespray inventory reordered and a new control plane node joined

Breaking change in an upgrade3 cases

  1. IL-0198 An automatic Ubuntu security update restarted systemd-networkd, which flushed the IP rules Cilium relied on and cut more than 60 percent of Datadog's Kubernetes nodes off the network across regions and cloud providers
  2. IL-0501 Every node of the UToronto Kubernetes cluster on Azure went NotReady and the JupyterHub became unreachable
    2i2c2022
  3. IL-0449 Pods on Enigmo's new EKS managed node groups kept restarting or stuck Terminating and the nodes became unusable
    Enigmo2020

Faulty deployment1 case

Organisation
  1. IL-0591 Gitpod workspaces in all regions became IO bound and unresponsive for days after the ws39 workspace cluster release
    Gitpod2022

Cloud provider outage2 cases

  1. IL-0172 An AWS Tokyo data centre cooling failure took down 6 of 60 CockroachDB nodes on Kubernetes within 22 minutes, and ranges lost quorum because the Helm-deployed cluster had no availability zone locality configured
  2. IL-0193 A GCP persistent disk degradation took down a Cassandra StatefulSet whose OrderedReady policy blocked recovery, and Metrictank could not reconnect to the recreated pods, causing a 23-hour Graphite query outage

unknown1 case

Contributing factor
Organisation
  1. IL-0402 mybinder.org launches dropped to zero for hours because a JupyterHub pod on a lost GKE node kept its hub database PVC