  1. Symptoms

    On 4 September 2025 a CoreDNS pod in a Cisco ThousandEyes Kubernetes cluster was OOMKilled.

    Trigger

    A CoreDNS pod was OOMKilled.

    Root cause
    Component
    Contributing factor
    Lessons

    The closing slide sets three behaviours side by side: Istio's extremely aggressive DNS cache refresh with one client port reused for all DNS requests, kube-proxy's lack of a cleanup mechanism for stale conntrack entries of terminated pods (fixed in Kubernetes v1.32), and conntrack's default bidirectional UDP stream timeout of 2 minutes. The speaker describes Istio as making some very complex things simple but some very simple things complex, and presents Cilium, which looks up Services in maps instead of walking the KUBE-SERVICES chain and can replace kube-proxy entirely with its eBPF data path.

  2. Symptoms

    During a deployment, traffic into the Kubernetes cluster started hitting dead ends: some API requests timed out and requests were slow and disrupted while the rollout ran.

    Trigger

    A deployment rollout changed backend endpoints while a long-running NGINX full reload was in progress, with the enable-serial-reloads option enabled on the ingress-nginx controller.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • restarted the NGINX Ingress controller as an attempt to resolve the problem
    Action items
    • Open an issue in kubernetes/ingress-nginx describing how enable-serial-reloads blocks dynamic endpoint updates
    Lessons

    A flag meant only to serialise full reloads also delayed endpoint updates, which opened a window during rollouts in which the ingress routed to pods that no longer existed. Options that change how the ingress controller applies configuration need to be checked against what happens to endpoint updates during a long reload.

  3. Symptoms

    Event ingestion and the Honeycomb UI in EU1 became unavailable at 22:00:10 UTC on April 9, 2024, and the status page reported that the EU1 instance was down. Both the ingestion service and the service behind the web UI stopped at roughly the same moment.

    Trigger

    A routine system update to the Kubernetes cluster, rolled out earlier on April 9, followed by a regular deployment that replaced pods one at a time.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, saying the EU1 instance was down, went up at 15:08 PDT (22:08 UTC), about 8 minutes after the outage began. There was no alerting on the AWS Load Balancer Controller.

    Remediation
    • Restarted the AWS Load Balancer Controller
    • Rolled back the Kubernetes cluster system update
    Action items
    • Find the exact cause of the failure so the system update can be deployed safely
    • Add monitoring and alerting on the AWS Load Balancer Controller so on-call engineers learn of a failure quickly and can pause deployments
    Lessons

    A rolling deployment can look healthy while the component that wires new pods into the load balancer is broken; the failure only shows when the last old pod goes away. Honeycomb now treats the AWS Load Balancer Controller as a critical component that needs its own alerting, so deployments can be paused before they remove the last pods that still receive traffic. Extensive testing in development and staging did not reveal the bad interaction.

  4. Symptoms

    On 5 October 2023 in us-central1, newly created VMs waited a long time before their networking worked, and VMs that had been live migrated lost connectivity for a long time after the migration. Networking telemetry showed cross-region packet loss to and from us-central1 from 03:08 US/Pacific. Health check state of VMs reached load balancers late.

    Trigger

    A management plane behaviour change, meant to decouple the processing of API updates to Instance Groups and Network Endpoint Groups used as load balancer backends, was deployed in us-central1 after rolling out to several other regions without incident.

    Root cause
    Component
    Contributing factor
    Detection

    Engineers were alerted to slowness in the virtual network control plane in us-central1 at 21:45 US/Pacific on 4 October, before the packet loss started, and to controller failures from memory exhaustion at 02:11 on 5 October. Networking telemetry showed cross-region packet loss from 03:08.

    Remediation
    • Increased the memory allocated to the virtual network router controllers
    • Rolled back the management plane change in us-central1
    • Restarted by hand the routers that were still not accepting updates
    Action items
    • Alert proactively on memory risks and unexpected memory increases
    • Refactor the deployment configuration so engineers can reallocate memory much faster
    • Re-evaluate existing practices and add safety mechanisms for API reconciliation
    • Make management plane changes more visible across teams so the changes can be correlated faster
    • Adjust the deployment footprint so a regional API change is less likely to exhaust memory across the region at once
    • Optimise memory use in the traffic routers and their controllers
  5. Symptoms

    LOTTE ON, Lotte E-commerce's online shopping mall of about 40 microservices on Amazon EKS, returned errors for a period of time whenever the Horizontal Pod Autoscaler (HPA) scaled pods in after load dropped. Requests reached containers that had already been deleted and failed with 502 errors.

    Trigger

    HPA scale-in deleting pods, and the deletion of Blue pods after a blue/green switch of the Service label selector.

    Root cause
    Component
    Contributing factor
    Remediation
    • delayed container shutdown on pod deletion (a wait in the SIGTERM handler or a preStop sleep, capped by terminationGracePeriodSeconds) so containers stop only after the pod has left the Service endpoints
    • switched some workloads' Ingress-created ALBs from instance mode to IP mode so traffic goes straight to pod IPs without iptables and conntrack
    Action items
    • Move all workloads to ALB IP mode gradually
    Lessons

    Removing a pod from Service endpoints and stopping its containers happen at the same time in Kubernetes, so a pod can stop while traffic is still routed to it unless shutdown is delayed with a preStop hook or in the application. With an instance-mode ALB, traffic passes through node iptables and conntrack, and established connections can keep going to a pod IP after its iptables rules are gone. IP mode avoids that path, within the limit of 1000 targets per target group.

Check your cluster for this

These 11 cases involve Ingress controller and Cloud load balancer. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause6

Software defect5 cases

  1. IL-0104 After a CoreDNS pod was OOMKilled, the talk names three causes: Istio's aggressive DNS cache refresh on one reused client port, kube-proxy not cleaning up conntrack entries of terminated pods, and the 2-minute UDP conntrack timeout
  2. IL-0081 API requests timed out during deployment rollouts because the ingress-nginx enable-serial-reloads option held back endpoint updates while a long NGINX reload was running
    Cresta2025
  3. IL-0062 Intermittent 502 errors behind a GKE Ingress because pods shut down before the load balancer stopped sending them traffic
  4. IL-0072 High etcd write latency made the API servers return stale data, and the production cluster flipped between two views of its state
  5. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Breaking change in an upgrade1 case

Organisation
  1. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced

Faulty deployment1 case

Organisation
  1. IL-0530 Virtual router controllers in us-central1 ran out of memory in a loop, cutting networking for new and migrated VMs

DNS or network fault2 cases

  1. IL-0178 On EKS, HPA scale-in returned 502 errors because containers stopped before their pod IPs left the Service endpoints, and after blue/green switches conntrack kept sending established connections to deleted pods behind an instance-mode ALB
  2. IL-0049 Partial DNS outage after CoreDNS scaled down and kube-proxy failed to delete stale conntrack entries
    Preply2020

Configuration change1 case

Organisation
  1. IL-0461 Every rollout of Datadog's metrics query service on Kubernetes raised errors that the logs blamed on DNS

Operator error1 case

  1. IL-0089 A test cluster deletion script run with the kube context pointing at the live-1 production cluster deleted its ingress controller, monitoring, logging, cert-manager, kiam and external-dns