Graph
Cases4 cases
1 to 4 of 4
IL-0559PubNub services degraded in US-East during an AWS outage in the IAD region, and failover load then degraded US-WestPubNub2025- Symptoms
At 07:06 UTC on 20 October 2025, PubNub's monitoring alerted on raised error levels across multiple services in the IAD (US-East) region. Customers could see higher error rates and latency, and Presence was intermittently unavailable in IAD, SJC (US-West) and HND (AP-Northeast).
- Trigger
A broad infrastructure outage at AWS, PubNub's cloud provider, in the IAD (US-East) region.
- Root cause
- Component
- –
- Contributing factor
- Detection
PubNub's monitoring systems alerted at 07:06 UTC on raised error levels across multiple services in IAD.
- Remediation
- Started regional failover procedures and re-routed new connections to other regions
- Reset established connections by hand
- Re-routed Presence traffic to Frankfurt (EU-Central)
- Brought on additional infrastructure in other regions to absorb traffic
- Isolated the US-East region again when the second wave hit US-West
- Scaled up balancer capacity in US-West
- Rebalanced traffic after AWS restored service and US-East was confirmed stable
- Action items
- Consolidate and centralise regional failover procedures so they are complete and immediately accessible for all production services
- Fill gaps in process documentation for newer services before they are fully adopted into production
- Fix internal tooling problems, including inventory and DNS resolution, that made mitigation harder
- Symptoms
From 7:30 AM PST on 7 December 2021, AWS services in us-east-1 that communicate between AWS's internal network and its main network saw rising latency and errors. The AWS operations teams lost real-time monitoring data at once, and the first thing found in the logs was elevated internal DNS errors.
- Trigger
At 7:30 AM PST an automated activity that scales the capacity of one AWS service hosted in the main AWS network triggered unexpected behaviour from a large number of clients inside the internal network.
- Root cause
- Component
- Contributing factor
- Detection
The congestion immediately cut off real-time monitoring data for the AWS operations teams, who turned to logs and first identified elevated internal DNS errors.
- Remediation
- Moved internal DNS traffic away from the congested network paths
- Isolated the top sources of traffic onto dedicated network devices
- Disabled some heavy network traffic services, including EventBridge event delivery
- Brought additional networking capacity online
- Disabled the automated scaling activities that triggered the event
- Action items
- Keep the triggering scaling activities off until all remediations are deployed
- Fix the latent issue that kept networking clients from backing off
- Deploy network configuration that protects the affected networking devices in a similar congestion event
- Keep API Gateway servers healthy when the internal network is unavailable and speed up their recycling
- Release a new Service Health Dashboard that makes service impact easier to understand
- Run the support system actively across multiple AWS regions
- Symptoms
At 5:15 AM PST on 25 November 2020, alarms fired for errors on putting and getting Amazon Kinesis records in the Northern Virginia (US-EAST-1) Region. From the same time CloudWatch, which processes metric and log data through Kinesis Data Streams, and CloudWatch Events and EventBridge returned more errors.
- Trigger
A relatively small addition of capacity to the Kinesis front-end fleet, made between 2:44 AM and 3:47 AM PST.
- Root cause
- Component
- Contributing factor
- Detection
Alarms for errors on putting and getting Kinesis records fired at 5:15 AM PST, and the teams began reviewing logs.
- Remediation
- Removed the newly added front-end capacity
- Added a configuration so front-end servers load bootstrap data from the authoritative metadata store instead of neighbouring servers
- Restarted the front-end fleet gradually, a few hundred servers per hour from 10:07 AM PST
- Added Cognito capacity to buffer more calls to Kinesis
- Deployed a change that reduced Cognito's dependency on Kinesis
- Mitigated the memory contention on the Lambda invocation hosts
- Informed customers through the backup Service Health Dashboard tool, the Personal Health Dashboard and a global banner
- Action items
- Move the Kinesis front-end to larger CPU and memory servers so fewer servers, and fewer threads per server, are needed
- Add fine-grained alarming for thread consumption
- Finish testing a higher operating system thread count limit
- Greatly improve the cold-start time of the front-end fleet
- Move the front-end server cache to a dedicated fleet
- Move a few large AWS services such as CloudWatch to a separate, partitioned front-end fleet
- Accelerate the cellularization of the front-end fleet to match the back-end
- Change the Cognito webservers so they sustain Kinesis API errors without exhausting their buffers
- Keep 3 hours of metric data in the CloudWatch local metrics data store, first in US-EAST-1 and then globally
- Train support engineers regularly on the backup tool for posting to the Service Health Dashboard
- Lessons
In the Kinesis front-end, the number of threads each server keeps grows directly with the number of servers in the fleet, so adding servers can push every server past an operating system limit at the same time. AWS sees cellularization of the front-end, already done for the back-end, as the way to keep the shard-map cache within a tested and operated range and to guard against unknown scaling limits.
IL-0222Google Cloud US regions had heavy packet loss and some went unreachable after the network control plane was descheduledGoogle Cloud2019- Symptoms
On Sunday 2 June 2019, with user impact beginning between 11:47 and 11:49 US/Pacific, Google Cloud projects in several US regions saw elevated packet loss from network congestion, and some regions became unreachable. Customers saw higher latency, intermittent errors and lost connectivity to instances in us-central1, us-east1, us-east4, us-west2, northamerica-northeast1 and southamerica-east1, while us-west1, Europe and Asia had no regional congestion.
- Trigger
At 11:45 US/Pacific a relatively rare type of datacenter maintenance event started in one physical location, and the automation that runs it descheduled logical clusters that also held network control plane jobs in other physical locations.
- Root cause
- Component
- Contributing factor
- Detection
Google engineers were alerted to the failure two minutes after it began and started the incident process used for the most serious production incidents. The first customer notice appeared on the status page at 12:53 US/Pacific.
- Remediation
- Lowered the priority of less critical network traffic classes to reduce congestion
- Halted the datacenter automation software responsible for the maintenance event
- Rescheduled the network control plane and its supporting infrastructure in each location
- Rebuilt and redistributed the lost network control plane configuration, rolling it out from 14:03
- Directed service traffic away from the affected regions
- Moved the Cloud VPN control plane in three regions out of its fail-safe state
- Action items
- Keep the maintenance automation off until safeguards stop it descheduling jobs in several physical locations at once
- Harden the cluster management software to reject such requests whatever their origin
- Reconfigure the network control plane to reject maintenance requests of the type involved
- Make the network control plane in each location persist its configuration
- Let the network stay in fail static mode longer when the control plane is lost
- Review, update and test emergency response tooling and procedures, including customer communication tooling, for such network failures
- Extend continuous disaster recovery testing to this and similarly catastrophic failures
These 4 cases involve Backbone network (WAN) and BGP routing. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause3
Cloud provider outage1 case
- Component
- –
- Contributing factor
- Organisation
Software defect2 cases
- Component
- Contributing factor
- Organisation
Capacity exhaustion1 case
- Contributing factor
- Organisation