  1. Symptoms

    Every service in the homelab Kubernetes cluster stopped answering: the V-Rising server, Grafana, Jellyfin and Linkding were all unreachable, and the Kubernetes API was down, so the cluster could not be managed at all. The outage was found by hand, about 3 hours after it began, when someone tried to use the services.

    Trigger

    A power outage forced the Kubernetes master node to reboot.

    Root cause
    Component
    Contributing factor
    Detection

    Manually, when someone tried to access the services; there were no automated alerts.

    Remediation
    • Connected a monitor to the master node and read the boot logs, which showed the kernel panic
    • Booted the previous kernel version, which brought the system back
    • Removed the broken Nvidia packages with sudo apt-get remove --purge '^nvidia-.*' and ran sudo dpkg --configure -a
    • Found remaining broken packages with dpkg -l | grep -v ^ii and removed them by hand
    • Ran sudo apt-get install -f and reinstalled linux-headers-$(uname -r)
    • Rebooted and confirmed the kernel panic was gone
    Action items
    • Make sure GPU driver installations fully succeed, or revert immediately when they fail
    • Move the cluster to a high-availability control plane
    • Expose the Kubernetes API through a load balancer in the HA setup
    • Set up a ticketing system to record incidents and their resolution
    • Write predefined troubleshooting workflows to shorten response time
    • Add infrastructure monitoring such as Prometheus and Grafana
    • Add blackbox HTTP and TCP checks from outside the cluster for critical services
    Lessons

    A driver installation that fails half-way can leave kernel packages broken without any visible effect until the next reboot, which may come weeks later and at the worst time. A failed DKMS build should be fixed or reverted at once. With a single master node and no monitoring from outside the cluster, one unbootable machine meant a total outage that nobody was told about; the fix itself was simple once the boot logs were seen.

  2. Symptoms

    During a rollout of the Grafana Loki distributor Deployment in one Grafana Cloud Logs environment, the write path went down for about 25 minutes. The newly started distributor pods were OOM-killed over and over, never passed their health and readiness checks, and the rollout stopped making progress.

    Trigger

    Step 1 of moving the Loki ring off a separately deployed key-value store onto embedded memberlist added a new label, gossip_ring_member: 'true', to the distributor pods and Service, together with a small config change, and the change required a rollout of the distributors.

    Root cause
    Component
    Contributing factor
    Detection

    The first clue was kubectl get pods and the kube_deployment_status_replicas_updated metric showing that only 16 of 140 distributor pods had been updated.

    Remediation
    • scaled the distributor Deployment out horizontally so the load spread over more pods with the new label and the rollout could continue
    • reverted the migration step to end the outage
    • set service_ignored_labels:: [$._config.gossip_member_label] and passed it to k.util.serviceFor so the label is no longer copied into the Service selector
    Action items
    • Update the function that generates a Service from a Deployment or StatefulSet to handle edge cases, including this one
    Lessons

    A Service whose selector is built by copying every label of a workload changes which pods it matches as soon as a new label is added. During a rollout it then matches only the new pods, which receive all the traffic before there are enough of them. A few errors during a rollout in other environments hid the problem, because those environments gave distributors more memory and could absorb the shift. Manifest diffs kept for every pull request made it possible to see that the Service selector had changed.

  3. Symptoms

    On the evening of a long-overdue upgrade of a loveholidays production GKE cluster from 1.10.X to 1.12.5-gke.10, planned to take 2 to 2.5 hours, the master upgrade and the first two 7-node NodePools went smoothly. After that the NodePool upgrades slowed to a crawl. Each node is cordoned, drained and upgraded in turn. Even a 14-node cluster at about 5 minutes per node took over an hour, and with about 100 more nodes to go, some of them taking over 15 minutes to drain, the sequential drains were too slow to finish at a reasonable hour.

    Trigger

    A manual upgrade of the GKE masters and NodePools from 1.10.X to 1.12.5-gke.10, two versions at once, on 19 March 2019; GKE's release notes of 14 March had already said that version was no longer available for new clusters or master upgrades because masters showed elevated error rates, but it could still be selected.

    Root cause
    Component
    Contributing factor
    Detection

    The slow drains, zombie nodes and stuck NodePool were seen by the engineer running the upgrade; the broken Ingress was noticed after the upgrade and explained by Google support; the HPA problem was noticed the next day.

    Remediation
    • drained the remaining NodePool nodes ahead of the upgrade with kubectl drain --ignore-daemonsets --delete-local-data
    • deleted the zombie instances from the managed instance group with gcloud compute instance-groups managed delete-instances
    • cancelled the stuck UPGRADE_NODES operation with gcloud beta container operations cancel
    • used kubectl port-forward in place of the broken internal Ingresses
    • scaled down the older of two active ReplicaSets, or triggered a dummy deployment, to bring the HPA back
    Action items
    • Alert when a HorizontalPodAutoscaler is at 70% and at 100% of its capacity
    • Alert when a deployment has had two active ReplicaSets for 30 minutes and for 60 minutes
    • Re-evaluate termination grace periods that were set to arbitrary large values
    • Read the GKE release notes before every cluster upgrade
    • Use auto-upgrade in non-production environments, and manual cluster upgrades with automatic node upgrades in production
    • Keep environments as identical as possible, including resource names
    Lessons

    Read the release notes before upgrading: the target version had been withdrawn five days earlier. Drain time depends on pod configuration, so emptyDir volumes, long grace periods and missing disruption budgets turn a NodePool upgrade into hours. Pre-production only catches problems like the ingress bug if it matches production down to resource names. Auto-upgrades in non-production surface problems early, and a mix of manual cluster upgrades and automatic node upgrades in production keeps clusters current without much effort.

  4. Symptoms

    The daily NRE Labs statistics showed lesson activity collapsing, and kubectl could not reach the cluster: `The connection to the server 1.2.3.4:6443 was refused - did you specify the right host or port?`

    Trigger

    Unknown. The liveness probe that kubeadm writes into the etcd static pod manifest (an `etcdctl get foo` against 127.0.0.1:2379, failureThreshold 8, timeoutSeconds 15) started failing. The author first suspected GCP maintenance the night before, but could not reproduce the probe failure by hand and does not know why it began.

    Root cause
    Component
    Contributing factor
    Detection

    The author saw lesson activity drop in the daily NRE Labs statistics during his morning routine.

    Remediation
    • removed the liveness probe section from the kubeadm-generated etcd static pod manifest and applied it between etcd restarts
    Action items
    • Add monitoring, especially for the single-node master
    • Run a basic "down for maintenance" page in Google Cloud Functions that points to Twitter for updates, to redirect to during outages
    Lessons

    Because all of the infrastructure is managed as code, the cluster could be rebuilt quickly, but destroying it before finding the cause also destroyed the evidence. Monitoring matters, especially with a single-node master. Read the restart counts in kubectl output, not just the Running status. Remember the fundamentals instead of expecting the issue to be more complicated than it is, and do not let the urgency of an outage push you into hasty decisions. Put up a maintenance page instead of leaving the site failing halfway.

  5. Symptoms

    While running the CI process on a local machine to test an application Helm chart, the SRE lead watched the pods with watch kubectl get pods. All pods reached Running, and then some went back to Pending. Two hours later the problem had grown and some pods showed the phase Unknown.

    Trigger

    A CI run installed the application's Helm charts for all four markets (Efritin.com, Tonaton.com, Ikman.lk and Bikroy.com) on the nonproduction cluster at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The SRE lead saw pods go from Running back to Pending while watching kubectl get pods during the CI run; no monitoring raised an alert, even when all three workers were not ready.

    Remediation
    • terminated the three worker nodes and let the auto scaling group replace them
    Action items
    • Fix the Datadog integration for the nonproduction AWS account and repeat the installs with telemetry
    • Increase the worker root EBS volumes from 20GB to 120GB
    • Keep common base images pulled on every node with a DaemonSet until kops supports user hooks
    • Configure different allocation limits for the different layers in Kubernetes
    • Discuss a highly available Tiller with the Helm team
    • Find a way to throttle the number of newly created pods
    Lessons

    An ordinary deploy of the application could collapse the cluster, because the default 20GB gp2 root volumes could not keep up with parallel image pulls and container starts. Without node metrics and pod phase metrics, three NotReady workers raised no alert. A single Tiller replica can block the deploy that would fix an outage.

Check your cluster for this

These 5 cases involve Kubernetes API server and kubelet. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause5

Software defect1 case

Organisation
  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days

Configuration change1 case

Organisation
  1. IL-0191 A label selector accidentally added to the Loki distributor Service matched only the new pods of a rollout, which took all write traffic, were OOM-killed and stalled the rollout

Cloud provider outage1 case

Organisation
  1. IL-0014 A GKE upgrade to a withdrawn version stalled on slow drains and a stuck node pool, then broke an ingress and confused the HPA

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe

Capacity exhaustion1 case

Organisation
  1. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down