  1. Symptoms

    From 22:47 UTC on 25 August 2026 the Buildkite web interface, REST API, Agent API, job queue and notifications stopped working for every customer. No one could create a build from the UI or the REST API, job dispatch was delayed, and some builds that were already running when the outage began stayed stuck until the services recovered.

    Trigger

    At 22:44 UTC an application deploy created a surge of new pods, which used up the free capacity on the existing nodes and made the EKS cluster scale out. Background worker pools with unusually high maximum replica counts were scaling out at the same time and kept asking for more pods while new nodes were still being provisioned. Together they produced an unusually high rate of change in applications, network endpoints and nodes, and with it a sudden rise in demand on CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, at 22:55 UTC, eight minutes after the outage began, said something had gone wrong, and at 23:05 UTC the status page said a sitewide outage was being investigated. CoreDNS query duration had been rising as the cluster grew, but a defect in a key monitoring query and too little monitoring of query volume meant this went unnoticed before the outage.

    Remediation
    • paused further application deploys
    • scaled CoreDNS from three to twelve pods
    • raised each CoreDNS pod's memory limit from 512 MiB to 2 GiB
    • expanded the system node pool that runs CoreDNS
    Action items
    • Increase immediate CoreDNS headroom: twelve pods instead of three, a 2 GiB memory limit instead of 512 MiB, and a larger system node pool
    • Enable EKS-managed CoreDNS autoscaling with a tested minimum replica count and enough capacity to spread the replicas across nodes and availability zones
    • Add direct alerts on CoreDNS query duration, query volume, goroutine growth, memory pressure, OOM restarts and available replicas, and track longer-term trends in capacity planning
    • Find other cluster-critical services that lack tested capacity, direct alerting, spread across failure domains, and either safe autoscaling or documented static headroom, and fix them
    Lessons

    A CoreDNS deployment sized once and left at a fixed size can carry a growing cluster for months and then fail on the first burst of churn it cannot absorb. When query processing slows, pending queries take up memory, the pods hit their limits and restart, and client retries keep the service down after the restart. Server-side DNS query duration and volume need their own alerts: here client-side latency was masked by unrelated application speed-ups, and a broken monitoring query hid the server-side trend. Maximum replica counts raised as a temporary measure remove the cap that normally stops runaway scaling when new nodes are slow to arrive.

  2. Symptoms

    On 19 August 2026 the first equipment-level signs in Nebius's us-central1 region appeared around 09:40 UTC: the InfiniBand fabric degraded and GPU over-temperature alerts began to accumulate. Customer reports followed shortly after 10:00. At 10:15 on-call engineers were paged on critical component temperature alerts, and the incident was declared at 10:21.

    Trigger

    A storm-related event at the data center building took the building management system offline and shut down the chilled-water cooling loop.

    Root cause
    Component
    Contributing factor
    Detection

    No facility-level alert fired, because the storm also disabled the building management system that monitors the facility. Engineers acted on component over-temperature alerts that paged on-call at 10:15 UTC, after InfiniBand degradation, GPU over-temperature alerts and customer reports; the temperature rise from about 09:15 was visible on dashboards but had no alert.

    Remediation
    • had the facility operator switch cooling to manual bypass mode and opened rack rear doors to vent heat
    • re-energised tripped racks, control-plane racks first
    • restored the regional infrastructure control plane by manual intervention
    • restarted block-storage host components to clear stale disk attachment state
    • raised the VM recovery rate limits by hand for the region-scale recovery
    • started the affected Managed Kubernetes control-plane instances by hand
    • applied a controlled stop and start to control-plane instances whose data disk had been left unattached
    • identified and started 104 customer VMs that the incident had stopped
    Action items
    • Complete a joint resilience review with the facility operator covering redundancy of facility-management and monitoring systems, cooling that keeps running when those fail, electrical protection of cooling equipment and on-site response
    • Add facility-level environmental alerting on cooling plant state and room temperature trend that pages on-call independently of the building management system
    • Set up a documented emergency escalation path with the facility operator, with an on-call contact tree and guaranteed response times
    • Define an emergency heat-load reduction procedure with criteria, ownership and mechanics for shutting down or degrading workloads during a cooling loss
    • Establish a dependency-ordered region cold-start procedure with clear ownership for each service layer
    • Run regular region-scale recovery drills that cover VMs, storage attachments and Managed Kubernetes clusters
    • Fix the disk-attachment bug that extended the Managed Kubernetes outage and deploy the fix to all production regions
    • Improve the recovery policies Compute users can configure, and move all Managed Kubernetes control-plane nodes to the improved policy
    • Automate reconciliation of stale storage attachment state after abrupt host failures
    • Remove in-region dependencies from monitoring startup and recovery, and extend cross-region monitoring
    • Make regional health checks used for global traffic management reflect real service availability
    Lessons

    Facility monitoring that runs on the same system it watches goes silent in exactly the failure it should report, and with no alert on the room temperature trend there was no practical window to shed heat load in a controlled way. A cold start of a whole region exercised recovery paths built for isolated failures: single-attempt VM recovery, conservative rate limits and stale disk attachments all needed manual work. The longest part of the outage was restoring customer resources, Managed Kubernetes control planes above all, so Nebius is extending its recovery drills to that layer.

  3. Symptoms

    Every rolling update of the team's microservices on Amazon EKS, behind an Application Load Balancer, was followed by intermittent 502 and 503 errors for users. A Slack message at 3 a.m. read "배포는 성공했는데, 서비스는 죽었다" (the deployment succeeded, but the service died). Every pod was Ready and Datadog was green while users saw errors.

    Trigger

    A rolling update of a Deployment served through an ALB that registers pod IPs as targets, with no pod readiness gates.

    Root cause
    Component
    Contributing factor
    Detection

    A Slack message at 3 a.m. reported that the deployment had succeeded but the service was down; Datadog dashboards were green at the time.

    Remediation
    • labelled the namespace with elbv2.k8s.aws/pod-readiness-gate-inject=enabled so the AWS Load Balancer Controller injects pod readiness gates and Kubernetes waits for the ALB target to be healthy before deleting old pods
    Lessons

    A pod being Ready in Kubernetes does not mean the load balancer will send it traffic. Without a readiness gate, a rolling update can delete the old pods while the ALB still considers the new targets unhealthy, and dashboards that track pod status stay green during the errors. Making pods wait longer on shutdown reduced the errors but did not fix the start-up gap and made every deployment much slower; the readiness gate ties the pod's Ready state to the ALB's view of the target.

  4. Symptoms

    During a Lunar New Year event in January 2024, a developer posted a message in Slack suspecting an outage. While several people were checking it, the problem grew into a full outage of Backpackr's web and app services, and the company decided to stop the event.

    Trigger

    An unexpected traffic surge, more than three times normal, during the Lunar New Year event in January 2024.

    Root cause
    Component
    Contributing factor
    Detection

    A developer reported a suspected outage in Slack; the outage became total while several people were still confirming it.

    Remediation
    • stopped the Lunar New Year event
    Action items
    • Raise net.netfilter.nf_conntrack_max on all nodes to memory bytes/16384/2, and three times that on Istio nodes, applied by the nodeOptimizer DaemonSet
    • Configure Istio mesh networking so sidecars communicate directly instead of through the ingressGateway
    • Upgrade the Istio nodes from c6.xlarge (12.5 Gbps) to n-type instances with up to 25 Gbps of network bandwidth
    • Strengthen monitoring with ENA network bandwidth and packet drops, detailed Istio ingressGateway and sidecar metrics, and CPU, memory and saturation
    Lessons

    When every request in a cluster goes through one ingress gateway node, that node's connection tracking table and network bandwidth set the limit for the whole service. The default nf_conntrack table size was too small for three times normal traffic, and once it filled, packets were dropped. After the outage Backpackr strengthened its monitoring of network bandwidth, packet drops and the Istio components.

  5. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

Check your cluster for this

These 17 cases involve Kubernetes API server and Ingress controller. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause7

Capacity exhaustion4 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0170 During a Lunar New Year event, traffic more than three times normal filled the nf_conntrack table on the EKS node running the Istio ingress gateway, dropping packets and taking down Backpackr's web and app services
  3. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  4. IL-0040 Parallel Helm installs saturated small gp2 root volumes on a kops cluster and left all three workers NotReady with the kubelet or Docker down

Dependency failure1 case

Organisation
  1. IL-0133 A storm shut down cooling at Nebius's us-central1 data center, and a disk hot-plug bug kept Managed Kubernetes control planes down for hours after power returned
    Nebius2026

Faulty deployment2 cases

  1. IL-0188 Rolling updates on EKS returned 502 errors for about 30 seconds because Kubernetes deleted old pods as soon as new pods passed readiness, before the ALB had marked the new pod targets healthy
  2. IL-0086 A deployment meant for a CircleCI test Kubernetes cluster also removed Traefik and Calico resources from the production cluster, taking down the CircleCI UI and runner.circleci.com

Software defect2 cases

  1. IL-0138 A failed Nvidia driver build left broken kernel packages on the only Kubernetes master node, which hit a kernel panic on reboot after a power outage and took the homelab cluster down for six days
  2. IL-0003 linkerd lost Kubernetes service discovery after an etcd reconfiguration, and restarting every linkerd instance turned failed payments into a full platform outage
    Monzo2017

Configuration change5 cases

  1. IL-0005 A new telemetry service overloaded the Kubernetes API servers of large clusters and broke DNS-based service discovery for all OpenAI services
    OpenAI2024
  2. IL-0116 A CNI configuration change incompatible with a hardware variant that exists only in production cut network connectivity in an OpenAI GPU cluster and took text-davinci-003 fully down
    OpenAI2023
  3. IL-0009 A duplicated generated name made Argo CD replace the InfluxDB Cloud production Application and delete the whole production environment
  4. IL-0111 Switching the main Kubernetes ingress controller from Traefik v1 to v2 stopped X-Forwarded headers being passed, which broke the Okta login flow for every service using Okta and stopped DFDS online bookings for over an hour
    DFDS2021
  5. IL-0008 An unresponsive OPA validating webhook crash-looped the API server during a GKE master upgrade, and node auto-repair then recreated every node

Breaking change in an upgrade2 cases

Organisation
  1. IL-0203 A routine Kubernetes cluster system update made the AWS Load Balancer Controller fail, so new pods were never registered with the ALB and Honeycomb's EU1 ingest and UI went down once the last old pods were replaced
  2. IL-0060 Kubernetes 1.24 upgrade removed the master node label that Calico route reflectors selected on, dropping all pod routes and taking Reddit down for 314 minutes
    Reddit2023

unknown1 case

Organisation
  1. IL-0059 Single-master Kubernetes control plane kept dying because the kubelet restarted a healthy etcd on a failing kubeadm liveness probe