IL-0400Public sector sites across Wales lost connectivity for over 8 hours as a PE router wrongly advertised a default routePSBA2026- Symptoms
On 25 March 2026 from about 16:40, public sector organisations on the PSBA network across Wales lost connectivity at their sites. The Service Desk saw about 400 alerts at 16:58, when a Major Incident was declared, about 1,500 at 17:05 and about 5,000 across Wales at 17:08, while councils, a fire and rescue service and Natural Resources Wales phoned in to report sites down.
- Trigger
At 16:30 a route map change was applied, outside formal change control, on a PSBA core Provider Edge (PE) router to leak MPLS VPN routes, so that legacy Capita-operated UPS devices in a /16 subnet could be managed by BT/PSBA. The change was removed at 16:40.
- Root cause
- Component
- Contributing factor
- Detection
At 16:57 Mid Wales Fire & Rescue Service phoned in a loss of connectivity at its Presteigne site, and at 16:58 a case was opened in Service Now for a group of about 400 alerts and a Major Incident was declared.
- Remediation
- Removed the route map change from the PE router at 16:40
- Changed QoS on the BGP to bring back the management links, after which alarms cleared
- Cleared routes and reset inbound BGP advertisements, which did not stop the default route being advertised
- Corrected the configuration issue affecting the internet learned route at 01:02
- Performed a controlled reload of the affected router at 01:10, which restored customer services and management connectivity
- Action items
- Reinforce change control requirements with an internal briefing on formal change submission, the risks of unplanned changes and roles during planned and emergency changes
- Create a dedicated Microsoft Teams channel as the single real-time communication point for all live P1 and Major Incidents
- Explore disaster recovery and business continuity test exercises for major or P1 incidents
- During loss of management access, have all technical teams assess customer impact from what reporting organisations provide, captured and shared in real time by the Service Desk and Incident Management
- Investigate a fixed link between Capital Quarter and the PSBA management racks in Vantage Data Centre at Newport, with dedicated management terminals and two-factor authentication for access outside the secure management platform
- Improve initial triage with stronger probing questions when incidents are reported and keep reassessing and communicating impact throughout the incident
- Review the P1 and Major Incident process so escalation criteria and timeframes are clearly defined, and train the Service Desk to recognise and escalate them early
- Review the PSBA estate for legacy configuration, set processes and timeframes for removing it and add controls so it is not introduced again
- Review email and SMS distribution lists and processes and reinforce Service Desk training on customer communications during P1 and Major Incidents
- Lessons
The report names eight lessons: a change was made outside PSBA change control; internal communication during the Major Incident was slow and fragmented; the organisation was not ready for a network-wide incident; losing management access stopped the resolver groups from seeing the network state and customer impact; the resolver groups did not understand customer impact in enough detail, which delayed finding the root cause; escalation to PSBA management was slow; legacy configuration left in the network contributed; and email and SMS communications did not reach some customers in time.
IL-0344Linode's US-West data centers in Fremont and Santa Clara lost connectivity as the fibre circuits between them failedLinode2023- Symptoms
On 12 February 2023, customers in Linode's US-West region could not reach their Linodes. Santa Clara customers lost Internet connectivity after a change made at 8:45 UTC until it was reverted at 10:13 UTC, and later in the day the connection between the Fremont and Santa Clara data centers was cut completely, leaving both with degraded service or a full outage until 16:25 UTC; customers could also have trouble provisioning, powering down or rebooting services.
- Trigger
A single link of the A-side fibre circuit between Fremont and Santa Clara went down on 11 February, the whole B-side circuit followed on 12 February, and during troubleshooting with the hardware vendor a non-intrusive command triggered a rare bug that took down all A-side links.
- Root cause
- Component
- Contributing factor
- Detection
The response team began investigating when the A-side link went down on 11 February. The status page opened at 10:22 UTC on 12 February to investigate reports of connectivity issues in the US-West region.
- Remediation
- Reverted the change that removed internet traffic from the Santa Clara border routers
- Performed an emergency code upgrade of both circuits, restoring connectivity between the sites
- Restored the B-side path with the hardware vendor and fiber provider, regaining full redundancy
IL-0431During Mackerel's move to AWS, PostgreSQL failed over to a replica that had stopped replicating, losing an hour of dataHatena2017- Symptoms
On 7 August 2017, while checking the application after the maintenance that moved Mackerel from an on-premises data center to AWS, the team found that data updated during a specific time window was missing. Everything written to the PostgreSQL database between 14:30 and 15:30 JST was gone.
- Trigger
One hour after the application was switched to the newly promoted primary db001, db001 lost network connectivity and the database failed over to the standby db002.
- Root cause
- Component
- Contributing factor
- Detection
The team found the missing data while checking how the application behaved after the migration work.
- Remediation
- Tried to restore the lost updates by hand from the table data left on db001 and gave up
- Tried point-in-time recovery from the base backup and WAL and gave up
- Built a new replica db003 with db002 as primary to restore redundancy
- Kept db001 in maintenance state for investigation
- Watched db002 for some time to confirm the problem did not recur, then completed the migration
- Action items
- Change the PostgreSQL replica creation script to set recovery_target_timeline = 'latest' in recovery.conf by default
- Add a check to a server configuration test tool such as Serverspec that recovery.conf contains recovery_target_timeline = 'latest'
- Lessons
A setting needed only for a rare layout, such as a grandchild replica during a migration, was applied by hand through a script option and was forgotten. Because recovery_target_timeline = 'latest' is harmless on ordinary standbys too, Hatena now sets it by default whenever a replica is created. The staging rehearsal used the same layout and steps but had the setting right, so it could not catch the mistake. Hatena notes that a similar layout may be used again for a future PostgreSQL upgrade or a move to another region.
These 3 cases involve Backbone network (WAN) and BGP routing. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause3
Configuration change1 case
- Component
- Contributing factor
- Organisation
Software defect1 case
- Contributing factor
- Organisation
Operator error1 case
- Contributing factor
- Organisation