Incident Library
Applied filters Root causeCapacity exhaustionFactorRetry stormClear allEvery case under the filters, with no sentence; newest first.
Suggested filters Search, and the values found in your words appear here.

Graph

  • Root cause
  • Component
  • Symptom
  • Contributing factor
  • Case

Cases10 cases

1 to 5 of 10

  1. Symptoms

    From 22:47 UTC on 25 August 2026 the Buildkite web interface, REST API, Agent API, job queue and notifications stopped working for every customer. No one could create a build from the UI or the REST API, job dispatch was delayed, and some builds that were already running when the outage began stayed stuck until the services recovered.

    Trigger

    At 22:44 UTC an application deploy created a surge of new pods, which used up the free capacity on the existing nodes and made the EKS cluster scale out. Background worker pools with unusually high maximum replica counts were scaling out at the same time and kept asking for more pods while new nodes were still being provisioned. Together they produced an unusually high rate of change in applications, network endpoints and nodes, and with it a sudden rise in demand on CoreDNS.

    Root cause
    Component
    Contributing factor
    Detection

    The first status post, at 22:55 UTC, eight minutes after the outage began, said something had gone wrong, and at 23:05 UTC the status page said a sitewide outage was being investigated. CoreDNS query duration had been rising as the cluster grew, but a defect in a key monitoring query and too little monitoring of query volume meant this went unnoticed before the outage.

    Remediation
    • paused further application deploys
    • scaled CoreDNS from three to twelve pods
    • raised each CoreDNS pod's memory limit from 512 MiB to 2 GiB
    • expanded the system node pool that runs CoreDNS
    Action items
    • Increase immediate CoreDNS headroom: twelve pods instead of three, a 2 GiB memory limit instead of 512 MiB, and a larger system node pool
    • Enable EKS-managed CoreDNS autoscaling with a tested minimum replica count and enough capacity to spread the replicas across nodes and availability zones
    • Add direct alerts on CoreDNS query duration, query volume, goroutine growth, memory pressure, OOM restarts and available replicas, and track longer-term trends in capacity planning
    • Find other cluster-critical services that lack tested capacity, direct alerting, spread across failure domains, and either safe autoscaling or documented static headroom, and fix them
    Lessons

    A CoreDNS deployment sized once and left at a fixed size can carry a growing cluster for months and then fail on the first burst of churn it cannot absorb. When query processing slows, pending queries take up memory, the pods hit their limits and restart, and client retries keep the service down after the restart. Server-side DNS query duration and volume need their own alerts: here client-side latency was masked by unrelated application speed-ups, and a broken monitoring query hid the server-side trend. Maximum replica counts raised as a temporary measure remove the cap that normally stops runaway scaling when new nodes are slow to arrive.

  2. Symptoms

    On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.

    Trigger

    On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.

    Root cause
    Component
    Contributing factor
    Detection

    On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.

    Remediation
    • rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
    • throttled connections and Redis writes on 21 October
    • halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
    • rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
    • increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
    • added retry limits to Envoy between the load balancer and the service
    • moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
    • added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
    Action items
    • Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
    • Investigate separating the flags Redis instance from the application Redis instance
    • Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
    • Make the feature flags team hard code-owners for flags-related code
    • Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
    • Add missing alerts on existing service and infrastructure metrics
    • Make readiness checks validate dependencies that degrade under load, for example by pinging the database
    • Rate-limit cache population so it cannot overwhelm Redis
    • Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
    • Build a production-scale load testing framework
    • Build progressive rollout infrastructure to limit blast radius
    • Document Postgres-to-Redis data flows and write runbooks for data transfer storms
    Lessons

    Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.

  3. Symptoms

    On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.

    Trigger

    On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.

    Root cause
    Component
    Contributing factor
    Detection

    As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.

    Remediation
    • Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
    • Fixed the control plane's periodic job so idle computes were terminated again
    • Restarted the aws-node DaemonSet several times, each with a temporary improvement
    • Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
    • On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
    • Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
    Action items
    • Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
    • Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
    • Change the architecture to support horizontal scaling
    Lessons

    With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.

  4. Symptoms

    At around 09:33 UTC one of the three control plane nodes of the Kubernetes cluster that hosts Magic Pages went offline. Looking at the node showed that it had run out of memory.

    Trigger

    One of the three control plane nodes ran out of memory and went offline at about 09:33 UTC; the attempts to replace it with hetzner-k3s failed while the cluster's own components were exhausting the Hetzner API rate limit.

    Root cause
    Component
    Contributing factor
    Detection

    The founder found the control plane node offline at about 09:33 UTC. Monitoring alerts about unreachable customer websites started around the time the replacement attempts failed, and about half an hour of investigation identified the exhausted Hetzner API rate limit.

    Remediation
    • powered off all servers of the Kubernetes cluster to stop the API requests so the Hetzner rate limit could recover
    • waited until ratelimit-remaining had built up a buffer before starting recovery
    • restarted the control plane servers
    • started the essential Longhorn components by hand so Longhorn could heal and make storage volumes available
    • restarted the remaining websites by hand
    Action items
    • Monitor the Hetzner API call rate coming from the Kubernetes cluster nodes themselves to get early warning of high usage
    • Get a higher Hetzner API rate limit; Hetzner support was contacted
    • Investigate how to reduce the cluster's reliance on a single API, including alternatives to hetzner-k3s
    • Document and test a procedure for recovering Longhorn after a full cluster shutdown
    Lessons

    The running cluster, not only the deployment tooling, consumed the cloud provider's API quota, and in a failure it consumed it fast enough that the quota never recovered. The default limit of 3600 requests per hour was not enough for failure and recovery scenarios, and API usage from inside the cluster was not monitored. A tool that hides the provider's API errors slows diagnosis. After a full, non-graceful shutdown, Longhorn needed manual intervention to come back, which lengthened the outage.

  5. Symptoms

    At 01:04 CET on 13 February 2024, the Kubernetes API behind Scaleway's managed Kubernetes services Kapsule and Kosmos in the Paris region (FR-PAR) spiked in RAM and CPU use and ran out of memory. Nodes in FR-PAR could no longer authenticate to their control plane, and some of them went "Not Ready". Customers on both shared (mutualized) and dedicated environments were affected.

    Trigger

    A new Kubernetes release was made available to all users on 12 February 2024, and during the night of 12 to 13 February many clusters triggered their auto-upgrade at the same time.

    Root cause
    Component
    Contributing factor
    Detection

    The timeline's first entry, at 01:04 CET, records the Kubernetes API's RAM and CPU spikes and out-of-memory state, with nodes unable to authenticate to their control plane and some becoming "Not Ready". The first recorded action, 42 minutes later at 01:46, was to increase the resources allocated to the API.

    Remediation
    • increased the resources allocated to the Kubernetes API at 01:46 and again at 02:20
    • applied API traffic restrictions at 02:30 to smooth the incoming traffic
    • removed the traffic restrictions progressively in 50-100 batches from 03:20
    • ran a script at 03:40 to replace the failing nodes created during the congestion
    • rolled back to the former node authentication mechanism, first on a subset of clusters from 15:45 and on all clusters by 19:41 on 19 February
    • disabled cluster upgrade and configuration update features until 10:30 on 20 February
    Action items
    • Increase the resources allocated to the Kubernetes API
    • Roll back to the former node authentication mechanism
    • Implement a local authentication cache on nodes
    • Rework the resource allocation strategy to behave better under load spikes
    • Add new request queuing mechanisms for Kubernetes
    • Separate the different components to reduce side effects under high load or failure
    • Monitor selected metrics closely to identify anomalous patterns earlier
    • Refund customers who deployed nodes during the incident but could not use them normally
    Lessons

    Letting many clusters auto-upgrade at the same moment after a release turns routine upgrades into one coordinated load spike on the shared Kubernetes API. A node authentication mechanism that retries without letting up turns a slow API into an unavailable one, and auto-healing that replaces NotReady nodes amplifies the problem. The congestion pattern had already appeared three weeks earlier, and short-term mitigations did not stop it from recurring, so Scaleway rolled back the new authentication mechanism. Scaleway notes that as the number of customer clusters and nodes grows sharply, traffic control mechanisms have to improve to prevent congestion.

Check your cluster for this

These 10 cases involve Container memory limit and In-memory cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1

Capacity exhaustion10 cases

  1. IL-0102 CoreDNS pods on a production EKS cluster ran out of memory under a burst of new pods, endpoints and nodes, taking down the Buildkite web UI, APIs and job dispatch
  2. IL-0100 PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queries
  3. IL-0006 VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletion
    Neon2025
  4. IL-0085 A control plane node of Magic Pages' Kubernetes cluster on Hetzner Cloud ran out of memory, the cluster's own calls then used up the Hetzner API rate limit, and all customer websites were down for about 7.5 hours
  5. IL-0168 Simultaneous cluster auto-upgrades overloaded Scaleway's Kubernetes API, and a node authentication retry loop kept Kapsule and Kosmos nodes NotReady in FR-PAR
  6. IL-0169 The Scaleway Kubernetes API in FR-PAR ran out of memory under simultaneous deployments, and because it also handled node authentication, Kapsule and Kosmos nodes went NotReady
  7. IL-0202 A burst of queries and database writes exhausted connection pools and memory on Honeycomb's ingest hosts, and Kubernetes crash-loop back-off kept failed hosts offline so ingest capacity stayed too low to recover
  8. IL-0140 The GKE API in us-central1 returned errors and high latency for 3 hours 19 minutes after an unexpected rise in backend traffic that client retries made worse
  9. IL-0076 Kubernetes masters went down after Dex filled etcd with AuthRequest objects and deleting its namespace started an endless list-and-timeout loop
  10. IL-0001 Cluster-wide DNS outage after CoreDNS pods were OOM-killed again and again under a burst of DNS queries