IL-0100PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queriesPostHog2025- Symptoms
On 21 October 2025 at 21:45 UTC a change to timeout handling was deployed to the feature flags service, and two minutes later automated monitoring reported higher error rates. The change was rolled back by 21:49, but error rates stayed high: about 38% of flag evaluation requests in the US datacenter returned errors. At 22:30 Redis metrics showed memory exhaustion on ElastiCache, at 22:35 Postgres connections spiked, and at 22:45 the team found a massive data transfer from Postgres into Redis. The main PostHog application was affected as well, because it shares the Redis instance with the flags service.
- Trigger
On 21 October a deployment meant to reduce timeout errors (PR #39821); on 24 October the deployment of IP-based rate limiting (PR #40074) that saw all traffic as coming from the load balancer's IP; on 28 October an unrelated routine deployment that rolled the feature flag pods in the US region.
- Root cause
- Component
- Contributing factor
- Detection
On 21 October automated monitoring detected higher error rates two minutes after the deploy. On 24 October no alert existed for 429 errors, and the team learned of the incident from customer reports that began at 18:10 UTC, a 62-minute detection delay. On 28 October on-call received a high error count alert. On 29 October the incident was reported with higher error rates and latency. No alert existed for CPU pressure, so the CPU saturation behind all three incidents was not seen directly.
- Remediation
- rolled back the timeout handling change within 2 minutes on 21 October, which did not stop the errors
- throttled connections and Redis writes on 21 October
- halted the rollout on 28 October, scaled the US flags pods to zero until Redis recovered, then scaled them back gradually
- rolled back hardware changes on 30 October at 00:03 UTC, which removed most errors but not the latency
- increased the pod resource requests and adjusted the Kubernetes fleet size so fewer pods ran on each node
- added retry limits to Envoy between the load balancer and the service
- moved database connection timeouts and other critical settings to runtime configuration and raised the timeout values
- added per-node and per-pod CPU alerts at 80% sustained for 5 minutes that page on-call
- Action items
- Form a strike team from the flags, ingestion and infrastructure teams to review the application and infrastructure for remaining bottlenecks
- Investigate separating the flags Redis instance from the application Redis instance
- Before re-enabling ArgoCD sync, align the flags service chart configuration with the values in ArgoCD and define the deployment and Redis strategy
- Make the feature flags team hard code-owners for flags-related code
- Build a dashboard of key flag metrics with runbook links and update the feature flag runbooks
- Add missing alerts on existing service and infrastructure metrics
- Make readiness checks validate dependencies that degrade under load, for example by pinging the database
- Rate-limit cache population so it cannot overwhelm Redis
- Monitor connection pools with automatic throttling near exhaustion and limit concurrent connections
- Build a production-scale load testing framework
- Build progressive rollout infrastructure to limit blast radius
- Document Postgres-to-Redis data flows and write runbooks for data transfer storms
- Lessons
Nodes that are small relative to pod requests let the scheduler pack many pods on each node, and the resulting CPU saturation showed up three different ways: excessive parallelism, connection pool exhaustion and slow queries. Treating each symptom separately let the problem return; right-sizing the pods and nodes fixed all three. CPU must be alerted on from the start. Unbounded Envoy retries and unbounded cache population amplified the overload, and a Redis instance shared with the main application spread a flags problem to the main application. A rollback did not end the incident, because the data transfer and resource exhaustion it had started kept running.
IL-0006VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletionNeon2025- Symptoms
On 16 May 2025, in Neon's Kubernetes cluster in AWS us-east-1, new compute pods were scheduled but could not start and failed with IP allocation errors. Each Neon compute is a Postgres database running in a lightweight virtual machine in its own pod, so without new pods, idle customer databases could not be woken up.
- Trigger
On 16 May the Neon control plane's periodic job that terminates idle computes started failing. Compute creations continued, and the number of active computes rose from about 5k to about 8.1k within minutes. On 19 May, a follow-up change that set WARM_IP_TARGET back to 1 started the second round of failures.
- Root cause
- Component
- Contributing factor
- Detection
As cluster-autoscaler added nodes, the team saw IP allocation errors on new pods that were scheduled but could not start. The rate of successful pod starts and VPC subnet metrics were then used to follow the problem.
- Remediation
- Set WARM_IP_TARGET=1 to release IPs held by nodes without free CPU or memory
- Fixed the control plane's periodic job so idle computes were terminated again
- Restarted the aws-node DaemonSet several times, each with a temporary improvement
- Set WARM_IP_TARGET=0, MINIMUM_IP_TARGET=0 and WARM_ENI_TARGET=0, which let nodes allocate enough IPs and stabilised the cluster
- On 19 May, set WARM_IP_TARGET back to 0 after setting it to 1 failed again
- Enlarged the pool of pre-created warm compute pods to absorb failed pod starts
- Action items
- Open a pull request to AWS CNI to improve how ipamd releases IPs in this situation
- Follow up with AWS Support about the roughly 100 subnet IPs that were never allocated, for reasons Neon could not explain
- Change the architecture to support horizontal scaling
- Lessons
With default settings AWS CNI can keep many IPs on nodes that cannot use them, so the share of subnet IPs assigned to pods does not tell how close the subnet is to running out. WARM_IP_TARGET and WARM_ENI_TARGET follow different logic, a warm IP target of zero switches to the ENI logic, and IPs in cooldown count toward the target, which behaves badly under high pod churn. Changing these settings during an incident without knowing that logic prolonged the outage, and reverting a setting did not bring back the earlier healthy state.
These 2 cases involve In-memory cache and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.
By root cause1
Capacity exhaustion2 cases
- Component
- Contributing factor
IL-0100PostHog's feature flags pods were packed onto Kubernetes nodes that were too small for their CPU requests, and CPU saturation above 90% caused three outages in ten days through Redis overload, connection pool exhaustion and slow queriesPostHog2025IL-0006VPC subnets ran out of IP addresses because the AWS VPC CNI kept IPs on full nodes, and WARM_IP_TARGET changes then blocked pod starts after every pod deletionNeon2025