  1. Symptoms

    The hub pod of the prod JupyterHub on the leap cluster (leap.2i2c.org) restarted unexpectedly during a large node scale-up, and a user opened a support ticket. The ingress-nginx and proxy pods kept running.

    Trigger

    A user's dask-gateway workload added about 100 dask-worker nodes within a minute, and Prometheus started scraping the metrics exporters on about 200 nodes.

    Root cause
    Component
    Contributing factor
    Detection

    A user support ticket (2i2c Freshdesk ticket 414) about the leap hub; the engineer then looked at Grafana and the cluster's nodes and events.

    Action items
    • Configure CPU and memory requests for the hub and proxy pods (#2127; at least 100m CPU was proposed)
    • Make the Grafana OOMKiller dashboard work (#2213)
    • Move LEAP cloud infrastructure to shared nodes (#2209)
    • Update resource requests and limits, mainly for ingress-nginx and Prometheus (#2324)
    • Decide whether Prometheus should scrape dask worker pods (#2366)
    Lessons

    Prometheus load grows with the number of nodes, so a burst of autoscaled nodes can push a nearly full core node over the edge and evict the pods that matter most. Core pods that request 10m of CPU get a tenth of the CPU share of busy neighbours that request 100m. Kubernetes events expire after an hour, so evidence of OOM kills needs a dashboard that keeps it.

  2. Symptoms

    A user of the LIS JupyterHub reported a "backoff after failed scale-up" error, and user servers would not start. An engineer opened incident #36, "LIS hub cannot scale", at 5:40 AM Pacific on 14 November 2022.

    Trigger

    At 10 AM UK time on 14 November 2022, the B zone of Google Cloud's europe-west2 region (London) ran out of resources to allocate. The LIS cluster's nodes were restricted to that zone.

    Root cause
    Component
    Contributing factor
    Detection

    A user reported the "backoff after failed scale-up" error; an engineer opened the incident at 5:40 AM Pacific, about three hours and forty minutes after the zone ran out of resources.

    Remediation
    • edited the node pool in the GCP console to allow node creation in the A and C zones of europe-west2, which were not exhausted
    Action items
    • Either restrict the node pool back to the B zone after the Black Friday event, or move the cluster and the NFS Filestore to the A zone (infrastructure issue #1944)
    • Investigate an enterprise plan that allows a regional NFS, at higher cost (infrastructure issue #1945)
    • Make sure PagerDuty notifications always get through to engineers (team-compass issue #574)
    Lessons

    A node pool pinned to one zone for storage performance cannot scale when the cloud provider runs out of capacity in that zone. The autoscaler's "backoff after failed scale-up" message usually points to quotas, and raising quotas does nothing here; the ZONE_RESOURCE_POOL_EXHAUSTED error in the logs is what identifies a zone without capacity. The review found that one engineer wearing many hats (incident commander, comms and debugging), with pages not reaching the other responders, made the response harder; a team response would have given more support.

Check your cluster for this

These 2 cases involve Node pool and Cluster autoscaler. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause2