  1. Symptoms

    Customers using Linode's US-MIA (Miami) and IT-MIL (Milan) data centers saw packet loss and brief performance problems on 14 September 2025 from 17:42 to 18:43 UTC. BR-GRU (Sao Paulo) had the same packet loss on 15 September 2025 from 01:44 to 04:22 UTC.

    Trigger

    A gradual increase in prefixes pushed the routing between the core router and the edge router past the maximum number of permitted prefixes.

    Root cause
    Component
    Contributing factor
    –
    Remediation
    • Raised the prefix limit on all the data center routers
    Action items
    • Raise the thresholds of the sessions between Akamai's backbone and the data center ECOR routers
    • Improve the existing alerting and check its severity before limits are reached, with escalation to the right team for immediate action