  1. Symptoms

    During a 50K GPU production pretraining job at OpenAI on Cluster A, all four links of one optical transceiver on a T0 switch flapped in rapid succession, and the job's throughput dropped by about 25% for the minute of flaps. The four links went to NICs on four different nodes, three of which were running in the job.

    Trigger

    An optical transceiver on a T0 switch had a glitch.

    Root cause
    Component
    Contributing factor
    –
    Detection

    The NICs detected their links going down and the T0 switch recorded the same links as down; the event is shown in the job's throughput and per-node packet loss graphs.

    Remediation
    • MRC recovered the packets lost during the flaps quickly, so the impact on the job stayed relatively small
    Lessons

    With MRC, failures of T0-to-T1 links and T1 switches have almost no effect on training, but NIC-to-T0 links and T0 switches still have a measurable effect and need more care. Most NIC-to-T0 link losses are transient, and a job can often recover to full speed quickly without evicting nodes.

Check your cluster for this

This case involves NIC, cable and switch port link. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1