  1. Symptoms

    On a Friday afternoon a tenant of SCHIP, Adevinta's multi-tenant Kubernetes runtime, reported a spike of HTTP 5xx errors in some of its services. The drops in quality of service came back periodically through the following days, each one short, and were reported mostly around midnight.

    Root cause
    Component
    Contributing factor
    Detection

    A tenant reported a spike of HTTP 5xx errors in some of its services; the DNS Latency SLI had already been degraded for some time without being acted on.

    Remediation
    • raised the dnsmasq concurrent query limit from 150 to 1500
    • added a CoreDNS header block that sets the ra and aa flags and clears rd, so dnsmasq caches cluster.local answers
    • configured dnsmasq on each node to answer NXDOMAIN for unresolvable search-domain names instead of forwarding them to CoreDNS
    • changed the fluent-bit log router hostname to a fully qualified name
    • asked the affected tenants to use fully qualified names for internal calls
    Lessons

    The DNS Latency SLI had shown the problem long before anyone looked at it. An SLO only protects you when its SLIs are trusted and a drop is investigated. The investigation took a month partly because several on-call groups worked on it separately, without one place for observations and hypotheses, and sometimes chased hypotheses already discarded. Disprove one hypothesis before starting the next, and collect data the metrics system lacks: DNStop showed the garbage lookups that no dashboard did. With ndots:5, short service names multiply DNS traffic; a node-local cache only helps if it can cache the cluster DNS answers at all.

  2. Symptoms

    On the Saturday the production cluster was moved from kops to EKS, the platform became very slow and too unstable to keep running, and the team reverted.

    Trigger

    Production was moved from a kops cluster using Weave networking to a new EKS cluster using the AWS VPC CNI, without external SNAT enabled.

    Root cause
    Component
    Contributing factor
    Detection

    The team lead saw the platform behaving very slowly after the switch to EKS and phoned the author.

    Remediation
    • reverted production to the kops cluster
    • set AWS_VPC_K8S_CNI_EXTERNALSNAT=true in the AWS VPC CNI
    Action items
    • Monitor and alert on the AWS VPC CNI
    Lessons

    In a networking problem every component in the stack is a suspect; ruling out EKS early cost a lot of time. A DaemonSet that pinged every component from every other one exposed the anomaly that led to the fix. The team had only skimmed the AWS CNI documentation before the migration; knowing how the plugin works internally would have led to better judgements and hypotheses while debugging.

  3. Symptoms

    Prometheus alerts fired on tail latency: from 7/24, the p99 response time of a few services went up after Prezi moved its Nginx-based reverse proxy, smartgateway, from dedicated Elastic Beanstalk machines onto shared Kubernetes worker nodes. The bump affected only the tail, so the earlier monitoring of average response times would most certainly have missed it.

    Trigger

    Moving the reverse proxy onto shared EKS worker nodes, where its outgoing connections went through source NAT on the node and some SYN packets were dropped by a race in Netfilter's conntrack.

    Root cause
    Component
    Contributing factor
    Detection

    Prometheus alerts on p99 latency fired after the reverse proxy migration.

    Remediation
    • added AWS X-Ray tracing and an $upstream_connect_time trace attribute to locate the delay
    • ran more pods of the service on more nodes, which reduced but did not end the delays
    • set AWS_VPC_K8S_CNI_EXTERNALSNAT=true on the AWS VPC CNI to turn off SNAT on the nodes
    Lessons

    Alerting on tail latency instead of averages caught a problem that would otherwise have gone unnoticed, and tracing turned a vague slowdown into a measured connect delay. Delays of exactly 1 or 3 seconds on new outgoing connections point to dropped SYN packets, and on EKS the SNAT done by the VPC CNI is where to look.

  4. Symptoms

    Pod-to-pod calls were intermittently slow and the web application felt slow overall. A request that pod A sent at time x reached pod B at x + 5s, x + 10s or x + 15s, always a multiple of five seconds.

    Trigger

    The C library resolver sent the A and AAAA queries for each lookup on the same port; where DNAT or SNAT translation takes place, a race condition in conntrack sometimes left one of the queries unanswered, and the resolver waited 5 seconds before retrying.

    Root cause
    Component
    Contributing factor
    Detection

    The team noticed intermittent delays in pod-to-pod calls and slowness in the web application, and that the delays were always multiples of five seconds.

    Remediation
    • added the single-request-reopen option to dnsConfig in the deployment specs
    • set GRPC_DNS_RESOLVER=native in the Dockerfiles of gRPC applications so they used the libc resolver
    • checked with tcpdump port 53 that A and AAAA queries left from different ports
    Lessons

    Delays that are exact multiples of five seconds point to DNS lookups being retried after the resolver's 5-second timeout. A resolver option set in the pod spec only helps processes that use the libc resolver; runtimes with their own resolver, such as gRPC with c-ares, ignore it.

Check your cluster for this

These 4 cases involve conntrack table and Client-side DNS resolver and cache. kubegap audits a Kubernetes cluster for gaps like these, read-only, from Claude Code or Codex; its checks cite public reports like the ones in this library.

By root cause1