Incident Library

IL-0228 OVHcloud · 2021-10-13networking

IPv4 routing across OVHcloud's global network broke after a router change put the full internet routing table into OSPF

OVHcloud runs a global network that is fully meshed, so every router is connected to the others directly or indirectly and constantly exchanges routing information with them. After weeks of rising DDoS attacks, OVHcloud prepared a configuration change to improve its defences; the Change Advisory Board validated it per the Method of Procedures with peer review, and it was announced on 2021-10-12. The change began at 09:05 CET, and BGP isolation and configuration updates went as expected at 09:18 CET. At 09:20 CET the misinterpreted command announced the whole internet routing table into the IGP, which overloaded routers and set off the BGP and OSPF convergence loop.

The crisis management process started at 09:25 CET. After the rollback failed, a datacentre technician started work in the telecom room at 10:00 CET (3:00 am local time), first disconnecting the optical equipment to isolate connectivity. The faulty router was powered off at 10:18 CET, network convergence took two minutes, and the first services came back at 10:20 CET. With the router, named D2, offline, the network converged, the OSPF tables emptied and traffic returned to the nominal gateways; the crisis ended technically at 10:57 CET. OVHcloud's earlier update at 11:30am the same day gave 9:12am CET for the start of the intervention and 10:15am for isolating the equipment.

Severity
–
Scope
IPv4 routing across OVHcloud's global network and all OVHcloud sites; IPv6 traffic unaffected
Users affected
–
Region
global
Time to detect
1m
Time to resolve
1h 37m

Symptoms

At 09:20 CET on 13 October 2021, during a planned change on a router, IPv4 traffic across OVHcloud's whole network stopped being routed, while all IPv6 traffic stayed reachable. The team detected a problem with the router's performance at 09:21 CET and escalated at once.

The entire internet routing table had been announced into OVHcloud's IGP. With the OSPF table full, routers' RAM and CPU were overloaded and some routers became unstable, and a convergence loop between BGP and OSPF made IPv4 routing inoperable, so IPv4 traffic could not be processed correctly on any OVHcloud site.

The rollback procedure did not work, so at 09:30 CET the team decided to isolate the equipment physically and called for on-site support.

After the faulty router was switched off, the first services came back at 10:20 CET, and the crisis ended from a technical point of view at 10:57 CET.

Symptom Network unreachableService outage

Root cause

Trigger
A planned change to a router in the Vint Hill datacentre in the United States, meant to strengthen anti-DDoS protection, included a command to regulate the redistribution of BGP into OSPF, and the router did not interpret that command correctly.

Detection

At 09:21 CET the team detected a problem with the router's performance and started the escalation process.

Remediation

Action items

Lessons

–